Preferred Language
Articles
/
jkmc-33
Role of MRI diffusion weighted imaging in differentiation between benign and malignant ovarian masses
...Show More Authors

Background: Characterization of the ovarian masses preoperatively is important to inform the surgeon about the possible management strategies. MRI may be of great help in identifying malignant lesion before surgery. Diffusion Weighted Imaging (DWI) is a sensitive method for changes in proton of water mobility caused by pathological alteration of tissue cellularity, cellular membrane integrity, extracellular space perfusion, and fluid viscosity.

Objective: to study the diagnostic accuracy of DWI in differentiation between benign and malignant ovarian masses.

Type of the study:Cross-sectional study.

Methods: this study included  53with complex ovarian mass or masses ,Diffusion Weighted Imaging was obtained to all these patient with correlation to the histopathological results; the Signal Intensity (SI) of the solid and cystic part of the lesions was evaluated on T2 and Diffusion Weighted Imaging  ,with Apparent Diffusion Coefficient (ADC) values were also obtained .

Results: 22 masses out of the total 53 were malignant and 31 were benign .On DWI the high SI intensity observed more frequently in the malignant lesions than the benign lesions (p value 0.0293) .There was significant difference between the mean ADC value of the malignant and benign ovarian lesions, with the mean ADC value for the benign lesions solid component =1.05 x10 -3, and the mean ADC value for the malignant lesions solid component =0.91 x10-3. The ROC study reveals that 0.926 x 10 -3  may be the optimal cutoff value  with sensitivity 54.8 %, specificity 59.1%, NPV 48.15 %, PPV 63.39%  , Accuracy 56.6%. With exclusion of the teratoma and endometriomas from statistical analysis the ROC reveals that 0.99 x10 -3  may be the optimal cut off value with sensitivity 76.9 % , specificity 77.3% , PPV 66.67% , NPP 85% and  accuracy 77.14% Conclusions: Combined with conventional pelvic MRI, DWI is a helpful tool in differentiation between benign and malignant ovarian masses, with high signal intensity on DWI more frequently observed in the malignant than benign ovarian lesions.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Sensors
WDARS: A Weighted Data Aggregation Routing Strategy with Minimum Link Cost in Event-Driven WSNs
...Show More Authors

Realizing the full potential of wireless sensor networks (WSNs) highlights many design issues, particularly the trade-offs concerning multiple conflicting improvements such as maximizing the route overlapping for efficient data aggregation and minimizing the total link cost. While the issues of data aggregation routing protocols and link cost function in a WSNs have been comprehensively considered in the literature, a trade-off improvement between these two has not yet been addressed. In this paper, a comprehensive weight for trade-off between different objectives has been employed, the so-called weighted data aggregation routing strategy (WDARS) which aims to maximize the overlap routes for efficient data aggregation and link cost

... Show More
View Publication Preview PDF
Scopus (35)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
The role of merger in creating differences in the profitability of companies Analytical research between a sample of subsidiaries to the Iraqi Ministry of Industry and Minerals
...Show More Authors

The research aims to identify the impact of the merger of the companies affiliated to the Ministry of Industry and Minerals on their financial profitability since the companies before the merger suffered a rise in losses and the deficit reached very high levels that affected its overall performance and even on the morale of workers as losses are increasing and solutions Efficiency is absent. The problem stems from knowing the impact of the merger on the profitability ratios of the companies. The research field was represented by the companies affiliated to the Ministry of Industry and Minerals (21) companies, while the research sample reached (6) companies after the merger (14) companies before the merger, was based on data The f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm

... Show More
Publication Date
Tue Jan 18 2022
Journal Name
Iraqi Journal Of Science
Improved Weighted 0-1 Knapsack Method (WKM) to Optimize Resource Allocation
...Show More Authors

In this paper an improved weighted 0-1 knapsack method (WKM) is proposed to optimize the resource allocation process when the sum of items' weight exceeds the knapsack total capacity .The improved method depends on a modified weight for each item to ensure the allocation of the required resources for all the involved items. The results of the improved WKM are compared to the traditional 0-1 Knapsack Problem (KP). The proposed method dominates on the other one in term of the total optimal solution value of the knapsack .

View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Approximated Methods for Linear Delay Differential Equations Using Weighted Residual Methods
...Show More Authors

The main work of this paper is devoted to a new technique of constructing approximated solutions for linear delay differential equations using the basis functions power series functions with the aid of Weighted residual methods (collocations method, Galerkin’s method and least square method).

View Publication Preview PDF
Crossref
Publication Date
Thu May 17 2018
Journal Name
Archaeological Prospection
Very‐high‐resolution electrical resistivity imaging of buried foundations of a Roman villa near Nonnweiler, Germany
...Show More Authors
Abstract<p>Electrical resistivity tomography (ERT) methods have been increasingly used in various shallow depth archaeological prospections in the last few decades. These non‐invasive techniques can save time, costs, and efforts in archaeological prospection and yield detailed images of subsurface anomalies. We present the results of quasi‐three‐dimensional (3D) ERT measurements in an area of a presumed Roman construction, using a dense electrode network of parallel and orthogonal profiles in dipole–dipole configuration. A roll‐along technique has been utilized to cover a large part of the archaeological site with a 25 cm electrode and profile spacing, respectively. We have designed a new field proce</p> ... Show More
View Publication
Scopus (18)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Thu Nov 11 2021
Journal Name
Nano Express
Near-infrared PbS quantum dots functionalized with affibodies and ZnPP for targeted imaging and therapeutic applications
...Show More Authors
Abstract<p>We report a new theranostic device based on lead sulfide quantum dots (PbS QDs) with optical emission in the near infrared wavelength range decorated with affibodies (small 6.5 kDa protein-based antibody replacements) specific to the cancer biomarker human epidermal growth factor receptor 2 (HER2), and zinc(II) protoporphyrin IX (ZnPP) to combine imaging, targeting and therapy within one nanostructure. Colloidal PbS QDs were synthesized in aqueous solution with a nanocrystal diameter of ∼5 nm and photoluminescence emission in the near infrared wavelength range. The Z<sub>HER2:432</sub> affibody, mutated through the introduction of two cysteine residues at the C-terminus (</p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Identification Pseudomonas aeruginosa by 16s rRNA gene for Differentiation from Other Pseudomonas Species that isolated from Patients and environment
...Show More Authors

Pseudomonas aeruginosa is a common and major opportunistic human pathogen, its causes many and dangersinfectious diseases due to death in some timesex: cystic fibrosis , wounds inflammation , burns inflammation , urinary tract infection , other many infections otitis external , Endocarditis , nosocomial infection and also causes other blood infections (Bacteremia). thereforebecomes founding fast and exact identification of P. aeruginosafrom samples culture very important.However, identification of this species may be problematic due to the marked phenotypic variabilitydemonstrated by samples isolates and the presence of other closely related species. To facilitate species identification, we used 16S ribosomal DNA(rRNA) sequence data

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jan 02 2023
Journal Name
International Journal Of Nonlinear Analysis And Applications
Diagnostic COVID-19 based on chest imaging of COVID-19: A survey
...Show More Authors

Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Effect of Diffusion Temperature on the some Electrical Properties of CdS:In Thin Films Prepared by Vacuum Evaporation
...Show More Authors

CdS films were prepared by thermal evaporation technique at thickness 1 µm on glass substrates and these films were doped with indium (3%) by thermal diffusion method. The electrical properties of these have been investigated in the range of diffusion temperature (473-623 K)> Activation energy is increased with diffusion temperature unless at 623 K activation energy had been decreased. Hall effect results have shown that all the films n-type except at 573 and 623 K and with increase diffusion temperature both of concentration and mobility carriers were increased.

View Publication Preview PDF
Scopus Crossref