Background: Diabetes mellitus is a metabolic disorder affecting people worldwide, which require constant monitoring of their glucose levels. Commonly employed procedures include collection of blood or urine samples causing discomfort to the patients. Necessity arises to find alternative non invasive technique is required to monitor glucose levels. Saliva is one of most abundant secretions in the human body and its collection is easy, noninvasive and painless technique. Objective: The aim of this study was to determine the efficacy of saliva as a diagnostic tool by study the correlation between blood and salivary glucose levels and glycosylated hemoglobin (HbA1c%) in diabetes and non diabetes, and the comparison of salivary glucose level and blood HbA1c% with serum glucose level in healthy and diabetic subjects. Type of study: cross- sectional study.Method: Saliva and blood samples were collected from 40 patients visited the Baghdad hospital in Iraq who were previously diagnosed with non-insulin-dependent (type 2) diabetes mellitus and 10 healthy as control (male and female) in age group of 30-65 years. The samples were examined to determine blood and salivary glucose level by the glucose oxidase- peroxidase method and blood HbA1c% by the ion exchange resin method. Results: Our results showed significantly higher salivary and serum glucose level in diabetes compared to control and significantly positive correlation between salivary and serum glucose in diabetes, control, and both groups together; the blood HbA1c% in diabetes was significantly higher compared to control and found a positive correlation between blood HbA1c% and salivary and serum glucose level in diabetes and control. Conclusion: salivary glucose appears to be an indicator of serum glucose concentration in diabetes.
5-Fluorouracil is one of the commonly used chemotherapy drugs in anticancer therapy; unfortunately treatment with 5-FU by solely has many drawbacks low lipophilicity, low permeability, low molecular weight, and its relatively poor plasma protein binding; also a brief half-life therefore frequent administration is required to maintain the optimal therapeutic plasma level which in addition to its poor selectivity, drug resistance and limited penetration to cancer cells; leads to increased incidence of side-effects to healthy cells/tissues and low response rates. In order to minimize these drawbacks; 5-FU was chemically conjugated with pyrrolidine dithiocarbamate (PDTC) in a mutual prodrug moiety (S-(9H-purin-6-yl) 3-(
... Show MoreA series of 4-(methylsulfonyl)aniline derivatives were synthesized in order to obtain new compounds as a potential anti-inflammatory agents with expected selectivity against COX-2 enzyme. In vivo acute anti-inflammatory activity of the final compounds 11–14 was evaluated in rat using an egg-white induced edema model of inflammation in a dose equivalent to 3 mg/Kg of diclofenac sodium. All tested compounds produced significant reduction of paw edema with respect to the effect of propylene glycol 50% v/v (control group). Moreover, the activity of compounds 11 and 14 was significantly higher than that of diclofenac sodium (at 3 mg/Kg) in the 120–300 minute time interval, while compound 12 expressed a comparable effect to that of di
... Show MoreDetecting the optimum layer for well placement, which requires a diverse assortment of tools and techniques, represents a significant challenge in petroleum studies due to its critical impact on minimizing drilling costs and time. This study aims to evaluate integrated geological, petrophysical, seismic, and geomechanical data to identify the optimum zones for well placement. Three different reservoirs were analyzed to account for lateral and vertical variations in reservoir properties. The integrated data from these reservoirs provides many tools for reservoir development, especially to detect appropriate well placement zones based on evaluations of reservoir and geomechanical quality. The Mechanical Earth Model (MEM) was construct
... Show MoreStereolithography (SLA) has become an essential photocuring 3D printing process for producing parts of complex shapes from photosensitive resin exposed to UV light. The selection of the best printing parameters for good accuracy and surface quality can be further complicated by the geometric complexity of the models. This work introduces multiobjective optimization of SLA printing of 3D dental bridges based on simple CAD objects. The effect of the best combination of a low-cost resin 3D printer’s machine parameter settings, namely normal exposure time, bottom exposure time and bottom layers for less dimensional deviation and surface roughness, was studied. A multiobjective optimization method was utilized, combining the Taguchi me
... Show MoreIn this work, the preparation of some new oxazolidine and thiazolidine derivatives has been conducted. This was done over two steps; the first step included the synthesis of Schiff bases A1-A5 in 72-88% yields by the condensation of isonicotinic acid hydrazide and aldehydes. The second step includes the cyclization of derivatives A1-A5 with glycolic acid and thioglycolic acid to obtain the desired products, oxazolidine derivatives B1-B5 (44-60% yields) and thiazolidine derivatives C1-C5 (41-61% yields), respectively. The structure of the prepared compounds was characterized using FT-IR, 1H NMR, and 13C NMR spectroscopy. Some of the produced compounds were tested for antioxidant properties.
Biometrics is widely used with security systems nowadays; each biometric modality can be useful and has distinctive properties that provide uniqueness and ambiguity for security systems especially in communication and network technologies. This paper is about using biometric features of fingerprint, which is called (minutiae) to cipher a text message and ensure safe arrival of data at receiver end. The classical cryptosystems (Caesar, Vigenère, etc.) became obsolete methods for encryption because of the high-performance machines which focusing on repetition of the key in their attacks to break the cipher. Several Researchers of cryptography give efforts to modify and develop Vigenère cipher by enhancing its weaknesses.
... Show MoreThis work represents development and implementation a programmable model for evaluating pumping technique and spectroscopic properties of solid state laser, as well as designing and constructing a suitable software program to simulate this techniques . A study of a new approach for Diode Pumped Solid State Laser systems (DPSSL), to build the optimum path technology and to manufacture a new solid state laser gain medium. From this model the threshold input power, output power optimum transmission, slop efficiency and available power were predicted. different systems configuration of diode pumped solid state laser for side pumping, end pump method using different shape type (rod,slab,disk) three main parameters are (energy transfer efficie
... Show MoreChaotic systems have been proved to be useful and effective for cryptography. Through this work, a new Feistel cipher depend upon chaos systems and Feistel network structure with dynamic secret key size according to the message size have been proposed. Compared with the classical traditional ciphers like Feistel-based structure ciphers, Data Encryption Standards (DES), is the common example of Feistel-based ciphers, the process of confusion and diffusion, will contains the dynamical permutation choice boxes, dynamical substitution choice boxes, which will be generated once and hence, considered static,
While using chaotic maps, in the suggested system, called
In this work a novel drug delivery system through modification of poly acrylic acid with Methionine as a spacer between the poly acrylic acid which was converted to its acyl chloride and reacted with Methionine as spacer unit which has been reacted with Ampicillin drug. In vitro drug release study had been conducted successfully in basic medium in pH 7.4 and acidic medium in pH 1.1 at 37?. Due to many problems associated with drug release and, this modification could decrease the side effect of drug. The prepared prodrug polymer was characterized by spectra method [FTIR and 1H?NMR]. Physical properties and intrinsic viscosity of drug polymer were determined. The good results were obtained in the presence of spacer unit with compar
... Show More