Preferred Language
Articles
/
jkmc-31
Clinical and experimental Study to evaluate the effect of Biphasic calcium phosphate collagen composite (cpcc) on healing of bone defects after oral surgical procedures
...Show More Authors

Background: A recent discoveries used for reconstruction in maxillofacial surgery is the composite bone graft materials. The availability of collagen I matrix make our choice to use this material in surgery .It is biomaterials that its structure could be modified by simple techniques. Studies to find a new materials use for bone reconstruction is to overcome the disadvantages of autogenous bone and the synthetic resorbable bone substitutes.

Objectives: This study was done to evaluate the effect of biphasic calcium phosphate collagen composite (ccpc) on healing of bone defects after oral surgical procedures.

Type of the study: A cross sectional study.

Method: It involved 60 patients, 35 male and 25 female, age (15-40) yearsand experimental animals study involved sixty rabbits.The study was done in Department of Maxillofacial surgery in Al anbarCollege of Dentistry (2015-2016).These patients were received tooth extraction, and other minor surgical procedures .Clinical and radiographical examination and patients consents are done before surgery. The surgery was done under local anesthesia.The resulting bone cavities are filled with composite bone graft material composed from combination of lyophilized hydrolysed collagen sponge (Hemospon),Brasil and Osteon II bone graft material,Korea .The area is closed with 3/0 block silk suture .Antibiotic cover (Ampicillin 500mg ×4) for 1 week was prescribed. The patients were followed up by careful clinical examination with radiograph 15-30 days after surgery. .Sixty New Zeleandi White rabbit were used in our study for histopathologicalexamination.Intraperitoneal injection of ketamine 10 mg with XYL-M2 solution 20 mg xylazine base used to anesthetize the animals. (5mm diameter) bone defects were made using straight surgical hand piece and bur in anterior mandibular region and filled with each material.  The study design involve the following groups: group 1( involve 15 rabbit; the defect was made and filled with blood clot only (control group),group 2( involve 15 rabbit, the defect was made and filled with collagen sponge only),group 3(Involve 15 rabbit, the defect was made and filled with Osteon II bone graft only),group4( involve 15 rabbit, the defect was made and filled with Osteon II bone graft +collagen (Composite bone graft).The flap were closed 3/0 black silk suture. The rabbits were killed after 30 days. 10 cmexcisional biopsy specimen was taken from the paramandibular area and placed in 10%formalin then send histopathologicalexamination.

Results:  Clinically, the treated area show good healing with absence of infection .Radiographs during follow up period show radiopacity indicating new bone formation .The results of experimental animals (Rabbits) indicategrowth new bone . In group 1 and group2, the center of the defects was depressed by surrounding tissues  Eung et al, While, in group 3&group 4, the graft materials maintained the space and the center of the defect did not depress. Statistical analysis indicates that during 4 th week ,the highest healing % is (100%) in group 3 &group4 in compared to control group (50%)..A significant difference in healing % was found among the treated groups.

Conclusion:The result indicates that biphasic calcium phosphate collagen composite can be efficiently utilized clinically.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL AND NUMERICAL STRESS ANALYSIS OF INVOLUTE SPLINED SHAFT
...Show More Authors

In this study, the induced splined shaft teeth contact and bending stresses have been investigated numerically using finite element method(Ansys package version 11.0) with changing the most effecting design parameter,(pressure angle, teeth number, fillet radius and normal module), for internal and external splined shaft. Experimental work has been achieved using two dimensional photoelastic techniques to get the contact and bending stresses; the used material is Bakelite sheet type “PSM-4”.
The results of numerical stress analysis indicate that, the increasing of the pressure angle and fillet radius decrease the bending stress and increase the contact stress for both internal and external spline shaft teeth while the increasing of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
The Effect of Laser And Thermal Treatment on the Hardness and Adhesion Force on the Cermet Coating By Thermal Spray Technique
...Show More Authors

Ceramic coating compose from a ceramic mixture (MgO, Al2O3) and metall (Al-Ni) were produced by Thermal Spray Technique. The mixed ratio of used materials Al:Ni (50%) and 40% of Al2O3 and 10% MgO. This mixture was spray on a stainless steel substrate of type (316 L) by using thermal spray with flame method and at spraying distances (8, 12, 16 and 20) cm, then the prepared films were treated by laser and thermal treatment. After that performing a hardness and adhesion tests were eximined. The present study shows that the best value of the thermal treatment is 1000 ℃ for 30 mint; the optimum spray distance is 12 cm and most suitable laser is 500 mJ where the microscopic and mechanical character

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Al–bahith Al–a'alami
Issues of Media Trials in Iraqi after 2003
...Show More Authors

The Supreme Judicial Council decided on July 3, 2003, to set up a court to deal with the issues of publication and media. This court tries to solve the problems of media and publishing in both its civil and penal aspects. The decision of establishing the court represents a new and important step to be taken by the Iraqi Judicial Council for the tremendous development witnessed by media sector in general and press in particular especially after 2003.
This study includes two main axes: the first one deals with the most important crimes of publication in the Iraqi legislations such as the crimes of defamation, libel, insult, indecency, and incitement; the second deals with an analytical survey of the completed cases i.e. the issues tha

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 20 2025
Journal Name
Journal Of Physical Education
The impact of a computerized program (cogniplus) to develop the strength to focus and perform kinetic chain on the balance beam
...Show More Authors

View Publication
Publication Date
Wed Jan 02 2019
Journal Name
Journal Of Educational And Psychological Researches
An Instructional Design According to the Active Learning Model and Its Effect on Students' Achievement in Chemistry for Fifth Intermediate Stage
...Show More Authors

The objective of the research is to identify the effect of an instructional design according to the active learning modelsالباحثين in the achievement of the students of the fifth grade, the instructional design was constructed according to the active learning models for the design of education. The research experience was applied for a full academic year (the first & the second term of 2017-2018). The sample consisted of 58 students, 28 students for the experimental group and 30 students for the control group. The experimental design was adopted with partial and post-test, the final achievement test consisted of (50) objectives and essays items on two terms, the validity of the test was verified by the adoption of the Kudoric

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 24 2020
Journal Name
Al-kindy College Medical Journal
The Functional Results of Surgical Percutaneous Joystick Reduction Therapy for Isolated Severely Angulated Radial Neck Fracture in Children
...Show More Authors

Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 20 2030
Journal Name
Al-kindy College Medical Journal
The Functional Results of Surgical Percutaneous Joystick Reduction Therapy for Isolated Severely Angulated Radial Neck Fracture in Children
...Show More Authors

Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
Structures
Behaviour and design of the ‘lockbolt’ demountable shear connector for sustainable steel-concrete composite structures
...Show More Authors

In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the t

... Show More
View Publication Preview PDF
Scopus (25)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Tue Jul 14 2015
Journal Name
Ibn Al-haitham J. For Pure & Appl. Sci.
Effect of Annealing Temperature and Thickness on the Structural and Optical Properties of CdSeThin Films
...Show More Authors

CdSe alloy has been prepared successfully from its high purity elements. Thin films of this alloy with different thicknesses (300,700)nm have been grown on glass substrates at room temperature under very low pressure (10-5)Torr with rate of deposition (1.7)nm/sec by thermal evaporation technique, after that these thin films have been heat treated under low pressure (10-2)Torr at (473,673)K for one hour. X-ray patterns showed that both CdSe alloy and thin films are polycrystalline and have the hexagonal structure with preferential orientation in the [100] and [002] direction respectively. The optical measurements indicated that CdSe thin films have allowed direct optical energy band gap, and it increases from (1.77- 1.84) eV and from

... Show More
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Artificial Accelerated Aging on The Color of Ceramic Veneers Cemented With Different Resin Cements (A Comparative In Vitro Study)
...Show More Authors

ABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co

... Show More
View Publication Preview PDF
Crossref (4)
Crossref