Background: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement, patients were imaged with sagittal short tau inversion recovery sequences and sagittal T2 weighted. Results: The mean age of the patients was 32.5 ± 6.7years; female to male ratio was 2.7:1. The total number of spinal cord MS lesions was 44 of them 86.4% in the cervical spine, 68.2%of the lesions had less than one vertebra extension,79.6% of the lesions did not show changes in the spinal cord morphology. There was a significant upgrading in the lesions conspicuity at short tau inversion recovery sequence comparing to T2 weighted image, P<0.001. A significant difference had been found in artifact grading between both sequences; P<0.001. Conclusions: short tau inversion recovery magnetic resonance image sequences improve detection of MS spinal cord plaques compared with T2 weighted image and itincreasesthe conspicuity of the visualized T2weighted image lesions, but also it accentuates theartifacts more than T2weighted image.
Building a system to identify individuals through their speech recording can find its application in diverse areas, such as telephone shopping, voice mail and security control. However, building such systems is a tricky task because of the vast range of differences in the human voice. Thus, selecting strong features becomes very crucial for the recognition system. Therefore, a speaker recognition system based on new spin-image descriptors (SISR) is proposed in this paper. In the proposed system, circular windows (spins) are extracted from the frequency domain of the spectrogram image of the sound, and then a run length matrix is built for each spin, to work as a base for feature extraction tasks. Five different descriptors are generated fro
... Show MoreBackground: Uncontrolled tumor cell proliferation is a reality in tumor cells, and the progression from a normal cell into a transformed cell probably includes genetic events affecting checkpoints in the cell cycle machinery.
Materials and methods: This study investigated the immunoexpression of p16INK4a in the paraffin sections from 43-cancers of colorectal tissue (CRC),26-hyperplastic polyps and adenomas(CRHPA) and 35-normal tissues (CRN),using immunohistochemical assay. We correlated the expression patterns with tumor histopathological type, site of the tumor, distance metastasis according to the TNM system.
Results: In colorectal cancer (CRC) patients’ p16INK4a,immunoexpression was detected in 32
Background: Postpartum hemorrhage is an important cause of maternal morbidity and mortality. Considerable difference of opinion exist regarding the optimal approach to the management of the 3rd stage of labour, practice varies between countries &between units.
Objectives: To evaluate the effectiveness of intra umbilical vein injection of oxytocin and umbilical cord driange in shortening the duration of third stage of labour.
Patient and Methods: In this randomized controlled study, 100 women were enrolled in this study they divided into three groups. (Group 1 ,N =30 )received 20 units of oxytocin diluted in 20 ml 0.9% saline solution injected in the umbilical vein after clamping.(Group 2, N = 34) placental cord drainage.(Group
Background: Postpartum hemorrhage is an important cause of maternal morbidity and mortality. Considerable difference of opinion exist regarding the optimal approach to the management of the 3rd stage of labour, practice varies between countries &between units.Objectives: To evaluate the effectiveness of intra umbilical vein injection of oxytocin and umbilical cord driange in shortening the duration of third stage of labour.Patient and Methods: In this randomized controlled study, 100 women were enrolled in this study they divided into three groups. (Group 1 ,N =30 )received 20 units of oxytocin diluted in 20 ml 0.9% saline solution injected in the umbilical vein after clamping.(Group 2, N = 34) placental cord drainage.(Group 3,
... Show MoreIn this study, light elements Li ,10B for (a,n) and (n,a) reactions
as well as o-particle energy from threshold energy to 10 MeV are
used according to the available data of reaction cross sections. The
more recent cross sections data of (a,n) and (n,a) reactions are
reproduced in fine steps 42 Kev for 10B(n,o) Li in the specified
energy range, as well as cross section (o,n) Values were derived from
the published data of (n,a) as a function of a-energy in the same fine
energy steps by using the principle inverse reactions. This calculation
involves only the ground state of Li OB in the reactions 'Li(a,n) B
B (n,a) Li
Introduction
When two charged nuclei overcome their Coulomb repulsion, a
rearrangement
Summary:
Background: The incidence of cancer of the cervix is comparatively low in Iraq, as in most other Islamic countries. Pre invasive lesions of the uterine cervix can be detected by Pap smears in their preclinical course, a fact which documents the significant role of cervical cytology in gynecological practice.
Objective: To emphasize the role of cervical cytopathology (Pap smears) in the detection and follow up of various cervical lesions that may predispose to cervical carcinoma with special emphasis on Cervical Intraepithelial Neoplastic (CIN) conditions or dysplasias.
Patients and Methods: This retrospective study M’as performed on 1500 women aged 20 years and above who attended the private clinical laboratory of th
Objective Using two complementary techniques of virus detection human papillomavirus (HPV)[capture of hybrids (CH) and polymerase chain reaction (PCR)], relate the cytological study and/or cervical biopsy with high-risk HPV (HPV-HR) genotypes presence, as well as relating their viral load (VL). Methods About 272 women, who presented most cell alterations compatible with lesions cervical HPV, which has been detected in all high risk by the CH method and HPV genotype detection by PCR. Results In 22% of the patients it was not detected HPV DNA. Genotype 16 and/or 18 was prevalent and was found in 33% of the 212 women studied, meanwhile, mixed infections were found by several genotypes in 25%. In as for the histological lesions found, in 61 pat
... Show MoreObjective: To study the effect of epidural spinal injection over one year in case of spinal stenosis. Methodology: This prospective study included 566 patients with spinal stenosis seen at Al-Kindy Teaching and Al-Sader, Hospitals who were treated by local epidural steroid injection. They were followed up for at least five subsequent visits after seven days, one month, three months, six months, and one year to assess efficacy. Result: Mean age of patients was 49.5 years, with a predominance of females (65%). L4/L5 was the most involved level in the spinal stenosis (70%). Grade II stenosis accounted for (45.4%) of cases. The pairwise comparison revealed that there was significant decrease in proportions of patients with pain in day
... Show MoreI
In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2)
... Show More