Preferred Language
Articles
/
jkmc-290
Diagnostic Value Of Post Exercise Systolic Blood Pressure Response In Ischemic Heart Disease
...Show More Authors

 Background: The normal decline in systolic blood pressure during recovery phase of treadmill exercise dose not occur in most patients with coronary artery disease, in others recovery values systolic blood pressure may even exceed the peak exercise value. Objectives: Treadmill exercise test parameters indicating the presence and extent of coronary artery disease have traditionally included such as exercise duration, blood pressure and ST-segment response to exercise. The three –minute systolic blood pressure ratio is another important indicator of presence and significance of coronary artery disease is useful and obtainable measure that can be applied in all patients who are undergoing stress testing for evaluation of suspected ischemic heart disease and this increase the sensitivity of exercise test . Type of the study: A prospective study. Methods: Between April 2011 and April 2012 ,all patients underwent treadmill exercise test , echocardiography coronary angiography in Ibn Ab-bitar Hospital Cardiac Surgery. Clinical and procedural data for patients undergoing treadmill and coronary angiography were prospectively collected and entered into database specially designed for the present study.To calculate mean systolic blood pressure ratio for each , Measurement of blood pressure in the 3rd minute of recovery time and divided by peak systolic blood pressure during exercise test ,after excluding patients . Coronary angiography was done for all patients who under went treadmill exercise test and multiple views were taken accordingly to clarify the lesion and critical lesion defined as >50% stenosis in LMS and >70% stenosis in LAD,LCX and RCA. Results: We studied 100 patients In the period from April 2011 to April 2012, 78(78%) male and 22 (22%) a female with a mean age 55.49±7.60 who undergone treadmill exercise testing and coronary angiography to assess the chest pain, 32 patient had normal blood pressure 68 had hypertension and 24 patients had normal coronary angiography and 76 patients had abnormal coronary angiography. SBP/3 minute recovery blood pressure ratio was significantly higher in patient with coronary artery disease than patient without coronary artery disease (mean ±SD O.92±0.09 VS 0.81 SBP/3 minute recovery blood pressure ratio was significantly related with the severity of coronary artery disease its higher in three vessels than one vessel disease 0.95±0.10 vs0. 91 ±0.01 p-value 0.0001. Conclusions: post exercise blood pressure response in patients with coronary artery diseaseis higher than patients with normal coronary artery .post exercise blood pressure is related to the severity of coronary artery disease

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Engineering
Prediction of Heat Transfer Coefficient and Pressure Drop in Wire Heat Exchanger Working with R-134a and R-600a
...Show More Authors

An experimental and theoretical works were carried out to model the wire condenser in the domestic refrigerator by calculating the heat transfer coefficient and pressure drop and finding the optimum performance. The two methods were used for calculation, zone method, and an integral method. The work was conducted by using two wire condensers with equal length but different in tube diameters, two refrigerants, R-134a and R-600a, and two different compressors matching the refrigerant type. In the experimental work, the optimum charge was found for the refrigerator according to ASHRAE recommendation. Then, the tests were done at 32˚C ambient temperature in a closed room with dimension (2m*2m*3m). The results showed that th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 28 2015
Journal Name
Journal Of Parasitic Diseases
The effect of toxoplasmosis on the level of some sex hormones in males blood donors in Baghdad
...Show More Authors

Toxoplasma gondii is a unique intracellular parasite, which infect a large proportion of the world population, but uncommonly causes clinically significant disease. The present study was performed to estimate the prevalence of toxoplasmosis in 400 apparently healthy blood donor males, their ages were between 18 and 57 years using enzyme linked immunosorbent assay, and to examine the effects of infection on total testosterone, free testosterone and follicle stimulating hormone (FSH) levels in their sera. Seroprevalence showed 10 (2.5 %) and 121 (30 %) of them had IgM and IgG antibodies respectively. Both acute and chronic toxoplasmosis in males recorded higher significant (P < 0.05) mean concentration for total and free testosterone hormone,

... Show More
Scopus (33)
Scopus
Publication Date
Thu Jan 01 2015
Journal Name
J. Math. Comput. Sci.
INTERVAL VALUE FUZZY n-FOLD KU-IDEALS OF KU-ALGEBRAS
...Show More Authors

In this paper, we will introduce the concept of interval value fuzzy n-fold KU-ideal in KU-algebras, which is a generalization of interval value fuzzy KU-ideal of KU-algebras and we will obtain few properties that is similar to the properties of interval value fuzzy KU-ideal in KU-algebras, see [8]. Also, we construct some algorithms for folding theory applied to KU-ideals in KU-algebras.

Publication Date
Wed Jul 31 2024
Journal Name
Iraqi Geological Journal
Correlating Capillary Pressure and Resistivity Index for Carbonate Reservoir
...Show More Authors

Capillary pressure is a significant parameter in characterizing and modeling petroleum reservoirs. However, costly laboratory measurements may not be sufficiently available in some cases. The problem amplifies for carbonate reservoirs because relatively enormous capillary pressure curves are required for reservoir study due to heterogeneity. In this work, the laboratory measurements of capillary pressure and formation resistivity index were correlated as both parameters are functions of saturation. Forty-one core samples from an Iraqi carbonate reservoir were used to develop the correlation according to the hydraulic flow units concept. Flow zone indicator (FZI) and Pore Geometry and Structure (PGS) approaches were used to identify

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Nov 20 2019
Journal Name
Proceedings Of The 2019 3rd International Conference On Big Data Research
Pressure Vessel Design Simulation Using Hybrid Harmony Search Algorithm
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Coil migration during pressure-cooker technique for cerebral AVM
...Show More Authors

Introduction: In recent decades, the endovascular treatment of cerebral arteriovenous malformations (AVMs) has advanced. However, it still carries risks of unanticipated complications. Coil migration is a reported complication of aneurysmal coiling procedures. Herein, we report a case of early intraprocedural coil migration during pressure cooker technique embolization of right thalamic AVM, discussing the management and potential explanations. The literature showed no report of coil migration after the pressure cooker technique in the form of coil-augmented Onyx injection technique (CAIT). Case description: An otherwise healthy 26-year-old female suddenly developed a severe headache with no loss of consciousness. Computed tomograp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determining Optimum Oil Separator Size and Optimum Operating Pressure
...Show More Authors

The optimum separators operating pressure is determined by using flash calculations and equilibrium ratios. In this study, the optimum separator size for Jambur field is calculated by using equations introduced by Arnold and Stewart and API12J Specification [1]. Because Jambur field has a high production rate two conditions are taken in the study to determine separator size, first based on production rate 80,000 bbl/day and second based on split the production between two banks A and B (40,000 bbl/day for each bank). The calculation resulted in optimum separator pressure for the first stage of 700 psi, and the second stage of 300 psi, and the third stage of 120 psi. The results show that as the number of stages increased above three-stag

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 31 2024
Journal Name
Iraqi Geological Journal
Correlating Capillary Pressure and Resistivity Index for Carbonate Reservoir
...Show More Authors

Capillary pressure is a significant parameter in characterizing and modeling petroleum reservoirs. However, costly laboratory measurements may not be sufficiently available in some cases. The problem amplifies for carbonate reservoirs because relatively enormous capillary pressure curves are required for reservoir study due to heterogeneity. In this work, the laboratory measurements of capillary pressure and formation resistivity index were correlated as both parameters are functions of saturation. Forty-one core samples from an Iraqi carbonate reservoir were used to develop the correlation according to the hydraulic flow units concept. Flow zone indicator (FZI) and Pore Geometry and Structure (PGS) approaches were used to identify

... Show More
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Physics: Conference Series
Impulsive Pressure Activity on MHD Flux Generalized Burgers Fluid
...Show More Authors
Abstract<p>The main purpose of the work is to analyse studies of themagnetohydrodynamic “MHD” flow for a fluid of generalized Burgers’ “GB” within an annular pipe submitted under impulsive pressure “IP” gradient. Closed form expressions for the velocity profile, impulsive pressure gradient have been taken by performing the finite Hankel transform “FHT” and Laplace transform “LT” of the successive fraction derivatives. As a result, many figures are planned to exhibit the effects of (different fractional parameters “DFP”, relaxation and retardation times, material parameter for the Burger’s fluid) on the profile of velocity of flows. Furthermore, these figures are compa</p> ... Show More
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determining Optimum Oil Separator Size and Optimum Operating Pressure
...Show More Authors

The optimum separators operating pressure is determined by using flash calculations and equilibrium ratios. In this study, the optimum separator size for Jambur field is calculated by using equations introduced by Arnold and Stewart and API12J Specification [1]. Because Jambur field has a high production rate two conditions are taken in the study to determine separator size, first based on production rate 80,000 bbl/day and second based on split the production between two banks A and B (40,000 bbl/day for each bank). The calculation resulted in optimum separator pressure for the first stage of 700 psi, and the second stage of 300 psi, and the third stage of 120 psi. The results show that as the number of stages increased above three

... Show More
View Publication Preview PDF
Crossref