Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
Epoxy resin has many chemical features and mechanical properties, but it has a small elongation at break, low impact strength and crack propagation resistance, i.e. it exhibits a brittle behavior. In the current study, the influence of adding kaolin with variable particle size on the mechanical properties (flexural modulus E, toughness Gc, fracture toughness Kc, hardness HB, and Wear rate WR) of epoxy resin was evaluated. Composites of epoxy with varying concentrations (0, 10, 20, 30, 40 weights %) of kaolin were prepared by hand-out method. The composites showed improved (E, Gc, Kc, HB, and WR) properties with the addition of filler. Also, similar results were observed with the decrease in particle size. In addition, in this study, mult
... Show MoreBackground: Pharmacy internship programmes are driven by most developed countries to outweigh the ongoing growth in the pharmacy career which encourages pharmacists to play a significant role as healthcare providers. Objectives: This study examines pharmacy students' perception, satisfaction, challenges, and limitations with the internship curriculum. Method: A cross-sectional study was conducted using an online survey with different elements to examine students' perceptions of various aspects. Result: Most students reported a positive impression regarding their internships, however, they were less satisfied with the allowance for filling prescriptions and compounding also, the college's follow-up was inadequate. F
... Show MoreBackground: Abdominoplasty is one of the commonest surgical procedures that performed for those patients who had skin laxity, strive and muscle rectur diastasis. Combined using of liposuction and abdominoplasty it can give better result than traditional abdominoplasty with fear complications. Patient and Method: A total number of 25 female patients with age ranging between 27-55 years were underwent lipoabdominoplasty. With extensive liposuction of abdominal wall and selective undermining together with muscle plication. All of our patients had body mass index more than 30. Patients satisfaction and complication were documented postoperatively. Result: All of our patients had no Major complications and the postoperative period passed unevent
... Show MoreA field experiment was carried out in one of the orchards of Al-Qassim district in Babel Governorate to find out the ability of a locally manufactured platform to serve palm trees by working in flat and uneven orchard land, palm tree heights of 4, 8, and 12 meters, and it performs pollination, pruning and harvesting services. The time of ascent and descent, the palm service, and the palm/hour productivity were measured. A randomized complete block design with three replications used a split split-plot arrangement. The nature of the land (flat or uneven) represented the main plots, the height of the palm trees (4, 8, 12) meters, the sub-plots, and the palm service operations (pollinati
Background: The altered status of some essential trace elements observed in diabetes could have deleterious influences on the health of the diabetics. Objectives: To estimate and study the potential role of serum Selenium in type 1, type 2 diabetics and healthy subjects; and its relation with lipid profile and glycemic index. Methods: A case control designed study was carried out at the National Diabetes Center (NDC) / Al-Mustansiria University; on a total of 94 participants formed of 32 type 1 diabetics, 32 type 2 diabetics and 30 healthy control participants. Data collected about age, sex and BMI; also, blood samples examined for FPG, HbA1C, serum total cholesterol, HDL cholesterol, non-HDL cholesterol, serum triglyceride and sera were
... Show MoreThis research focuses on improvement of the corrosion behaviour of commercial pure titanium (Ti) grade II when exposed to Hank’s solution through different surface treatments. The disc shape of titanium samples were constructed to be divided according to their surface treatment. The first experimental group the Ti sample was exposed to computer numerical control (CNC) fiber laser machine. Whereas, the other experimental group the Ti sample was only coated with Polyetherketon keton (PEKK) by using carbon dioxide (CO2) laser technique while the last experimental group the Ti sample was treated with CNC fiber laser followed by PEKK coating by using CO2 laser technique. All were compared with the untreated control group. The electrochemical a
... Show More