Preferred Language
Articles
/
jkmc-129
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter (D) ±3.17 (SD) with range from ₋6.00 to ₋18.00D and the mean cylinder was -2.61(D) ±1.16 with range from ₋1.00 to ₋5.50D .The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events.

Results: At 12 months postoperatively the mean Snellen decimal UDVA was 0.77±0.23 and mean CDVA was 0.80±0.21, with an efficacy index 1.16. Twenty nine  eyes (48.33%) showed gain in CDVA with safety index

 

 

1.21.The treatment was highly predictable for spherical equivalent and astigmatic component .The mean SE dropped from (₋12.63D ±3.11) to ( ₋0.11 D±0.20) with 58 eyes within ±0.50 D and 60 eyes with ± 1.00D of target correction . For achieved cylinder 60 eyes (100%) had ≤0.50D and 51 eyes (85%) had ≤0.25D with strong positive linear correlation between achieved and expected cylinder(r=0.94)

Conclusions: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Refractive index sensor based on a solid-core photonic crystal fiber interferometer
...Show More Authors

Photonic crystal fiber interferometers are widely used for sensing applications. In this work, solid core-Photonic crystal fiber based on Mach-Zehnder modal interferometer for sensing refractive index was presented. The general structure of sensor applied by splicing short lengths of PCF in both sides with conventional single mode fiber (SMF-28). To apply modal interferometer theory; collapsing technique based on fusion splicing used to excite higher order modes (LP01 and LP11). Laser diode (1550 nm) has been used as a pump light source. Where a high sensitive optical spectrum analyzer (OSA) was used to monitor and record the transmitted. The experimental work shows that the interference spectrum of Photonic crystal fiber interferometer

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
A comparative study to determine the native eye lens protein in the some types of Iraqi vertebrates
...Show More Authors

This study showed that the lens in baloot muluki fish Chondrostoma regium is transparent, spherical shape, and solid in textures, while in the tree frog Hyla arborea savignyi, freshwater turtles Clemmys caspia caspia, white–eared bulbul Pycnonotus leucotis and brown rat Rattus norvegicus are transparent, soft and biconvex, it is very soft in white–eared bulbul. There are many significant differences have been recorded between the average weight lens and the total concentration of the protein in the lens all studied animals. Electrical migration process for lens proteins showed that there is one bundle of crystalline –? and one bundle also crystalline–? in all studied species, either crystalline–? may represent one bundle character

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Design of an Electron Gun Using two Electrod Low Aberration Immersion Lens
...Show More Authors

Abstract
A two electrode immersion electrostatic lens used in the design
of an electron gun, with small aberration, has been designed using
the finite element method (FEM). By choosing the appropriate
geometrical shape of there electrodes the potential V(r,z) and the
axial potential distribution have been computed using the FEM to
solve Laplace's equation.
The trajectory of the electron beam and the optical properties of
this lens combination of electrodes have been computed under
different magnification conditions (Zero and infinite magnification
conditions) from studying the properties of the designed electron
gun can be supplied with Abeam current of 5.7*10-6 A , electron
gun with half acceptance

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
D-shape Optical Fiber Development and Enhancement as a Refractive Indices Sensor Using Surface Plasmon Resonance
...Show More Authors

This article showcases the development and utilization of a side-polished fiber optic sensor that can identify altered refractive index levels within a glucose solution through the investigation of the surface Plasmon resonance (SPR) effect. The aim was to enhance efficiency by means of the placement of a 50 nm-thick layer of gold at the D-shape fiber sensing area. The detector was fabricated by utilizing a silica optical fiber (SOF), which underwent a cladding stripping process that resulted in three distinct lengths, followed by a polishing method to remove a portion of the fiber diameter and produce a cross-sectional D-shape. During experimentation with glucose solution, the side-polished fiber optic sensor revealed an adept detection

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon May 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Foliar Applied Potassium and Cytokinin On Some Growth Parameters Of Lentil Plant (Lens culinaris Medic.).
...Show More Authors

The experiment was conducted in the glasshouse of Biology Dept. ,College of Education
Ibn- Al- Haitham ,University of Baghdad, during the growing season(2011), to study the
effect of sprying potassium sulphate at (0,200,400,600) ppm and cytokinin at (0,75,150)ppm
and their interactions on number of branches , protein percentage , carbohydrate percentage ,
absolute growth rate , biomass duration , relative efficiency of fertilizer and value of the
secondary productivity ,in Lentil plant cultivar(Baraka).
Results indicated that foliar sprying of potassium sulphate and cytokinin and their
interactions gave a significant effect on all vegetative growth parameters of lentil plant. the
concentration600 ppm of po

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Biological activity and protease inhibitor from watery extract of lentil (Lens culinaris) against some bacterial species
...Show More Authors

Biological activity substances was investigated in watery extract of lentil which found to contain phenols, tannin, saponins and resins while, flavons, terpens and steroids were not exist in the extract details explained that 5%, 10% of lentil extract largly inhibited the growth of Psedumonas aeruginosa then Escherichia coli and Bacillus subtilis. The growth of both Staphylococcus aureus and Salmonella typhimurium were slightly affected by all extract concentration. Extracellular protease were screened in all bacterial species under study. Complete inhibition was achieved for extracellular protease while different percentage of protease inhibition were seen for intracellular proteases.

View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Journal Of Medicine And Life
Effect and benefit of percutaneous coronary intervention in chronic total occlusion on ventricular repolarization: QT correction and dispersion
...Show More Authors

ST segment, T wave changes, QT interval changes, and QTc dispersion are among the parameters used to diagnose ischemic heart disease. The increase in the QT dispersion can be caused by myocardial ischemia, among other heart diseases, whereas cardiac diseases such as coronary artery disease (CAD) can be diagnosed by observing an abnormally high QTc dispersion. This study aimed to evaluate the variations in the QTc dispersion (depolarization and repolarization) of surface electrocardiography as a result of percutaneous coronary intervention (PCI) in patients with chronic total occlusion. This study took place in the Iraqi Center for Heart Disease from October 2020 to February 2021. 110 patients who suffered from chronic occlusion of t

... Show More
View Publication
Scopus (10)
Crossref (5)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Transplantation Proceedings
Outcomes of SGLT2 Inhibitors Use in Diabetic Renal Transplant Patients
...Show More Authors

View Publication
Scopus (57)
Crossref (57)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
The Electro-Excitation Form Factors of 7Li Nucleus with Exact Center of Mass Correction
...Show More Authors

The inelastic longitudinal electron scattering form factors are calculated for the low-lying excited states of 7Li {the first excited state 2121TJ (0.478 MeV) and the second excited state 2127TJ (4.63 MeV)}. The exact value of the center of mass correction in the translation invariant shell model (TISM) has been included and gives good results. A higher 2p-shell configuration enhances the form factors for high q-values and resolves many discrepancies with the experiments. The data are well described when the core polarization (CP) effects are included through effective nucleon charge. The results are compared with other theoretical models.
Keyword: 7Li inelastic electron scattering form factors calculated with exact

... Show More
View Publication Preview PDF
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
High optical correction system based 800x600 analog spatial light modulator
...Show More Authors

      In this work, a modern optical system based on modulation technique is constructed to achieve the retrieval of optical defects and distortions of the images behind dark barriers.  A 800x600 analog spatial light modulator (SLM) is used in this technique with a 632.8nm He-Ne laser, a circular metallic mesh (CMM) is imaged and disturbed and then dealing with our system. The SLM was confirmed for irregularity improvement such as variable diffracted optical element (DOE) control. The obtained results showed that the effect of distortion has been treated and reduced to be minimum by controlling phase and amplitude modulation of the scattered wave front utilizing the SLM. The obtained images showed identical to the original image wi

... Show More
View Publication Preview PDF
Scopus Crossref