Waters of some wells at Almuqdadea region Diyala province, east of Iraq have been
compared with wells at Alfalluja region, Alanbar province west of Iraq. Five wells were
selected randomly at each of the two regions to measure several factors represented by
temperature (C), P
H
, Electric Conductivity (EC), Sodium (Na),Calcium (Ca), Magnesium
(Mg),Total Hardness (TH), Carbonate (Co3),Chloride (Cl), Nitrite (NO2), Nitrate (NO3)
Phosphate (PO4) Sulfate (So4), in addition to the heavy metals such as Chromium (Cr),
Cadmium (Cd) Lead (Pb) & Iron (Fe). The mean concentration of the above factors in water
of wells at the above regions had been measured during the period from April to September
(2010).
Results of the present study revealed that all the heavy metals concentrations were less
than the sensitivity of the atomic absorption equipment with the exception of (Fe) which
recorded 0.358 ppm and 0.026 ppm at Alfalluja and Almuqdadea respectively. Results of the
present study were compared with the criteria used by (WHO) and (FAO). Results of the
present study revealed that all the metals concentration were undetectable by atomic
absorption equipment with the exception of (Fe) which recorded 0.358 ppm and 0.026 ppm at
Alfalluja and Almuqdadea respectively. The results showed that all concentrations recorded in
the present study were accepted with the international criteria used by the above organizations
except for EC, NO3, TH, and Na from Alfalluja wells as their levels were (2.208 m/sm,1.506
546.5 ppm, 3.53 gm/l) respectively. The unacceptable data from Almuqdadea wells were
represented by EC, TH, Mg and Na where their levels were (1170MGS\SM, 512.86ppm,
213.34ppm, 2.31gm\L) respectively. Finally the results showed that there were similarities in
the concentrations of some factors studied in the present project in the wells of the same area
and in some factors at both areas of study.
In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
This paper deals with finding an approximate solution to the index-2 time-varying linear differential algebraic control system based on the theory of variational formulation. The solution of index-2 time-varying differential algebraic equations (DAEs) is the critical point of the equivalent variational formulation. In addition, the variational problem is transformed from the indirect into direct method by using a generalized Ritz bases approach. The approximate solution is found by solving an explicit linear algebraic equation, which makes the proposed technique reliable and efficient for many physical problems. From the numerical results, it can be implied that very good efficiency, accuracy, and simplicity of the pre
... Show MoreAqueous extract of poppy plant) Papaver nudicaule) with five concentrations (50, 100, 150, 200 and 250) mg/l were used to anesthetize fingerlings of the common carp Cyprinus carpio (Mean total length 8.91 ± 0.31 cm and mean total weight 7.72 ± 1.19 gm) instead of the traditional use of MS-222. Results showed that extracted solution of poppy have partial and overall anesthesia effect on these fishes with inverse relationship between the concentrations used and the time needed to reach partial and overall anesthesia, and also direct relationship between concentrations used and time needed for fish recovery. Best results were obtained by using a concentration of 250 mg/l, where time for partial anesthesia was 8 ± 1.52 m
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show MoreZinc Oxide nanoparticles were prepared using pulsed laser ablation process from a pure zinc metal placed inside a liquid environment. The latter is composed of acetyltrimethylammonium bromide (CTAB) of 10−3 molarity and distilled water. A Ti:Sapphire laser of 800 nm wavelength, 1 kHz pulse repetition rate, 130 fs pulse duration is used at three values of pulse energies of 0.05 mJ, 1.11 mJ and 1.15 mJ. The evaluation of the optical properties for the obtained suspension was applied through ultraviolet–visible absorption spectroscopy test (UV/VIS). The result showed peak wavelengths at 210 nm, 211 nm and 213 nm for the three used pulse energies 0.05 mJ, 1.11 mJ and 1.15 mJ respectively. This indicates a blue shift,
... Show MoreIron status may influence the outcome of infertile women under the intracytoplasmic sperm injection (ICSI) technique of in vitro fertilization (IVF). The aim of this study is to evaluate iron status and ceruloplasmin ferroxidase activity in the follicular fluid (FF) and their association with IVF outcomes. The study enrolled fertile women with male cause infertility (n=25), infertile women with polycystic ovary syndrome (PCOS; n=21), infertile women with low AMH level (n=26), and women with unexplained infertility (UI; n=27), all undergoing IVF/ICSI. On the day of oocyte suction, the selection of FF samples was accomplished. Iron, ferritin, and transferrin levels, as well as ceruloplasmin (CP) ferroxidase activity, were measured
... Show MoreBackground: Non-small cell lung cancer (NSCLC) is caused of 85% of all lung cancers. Among the most important factors for lung tumor growth and proliferation are the tyrosine kinase receptors that coded by the epidermal growth factor recep-tor (EGFR) gene. Activation of EGFR ultimately leads to developing of lung cancer. The present study was undertaken with an objective to detect EGFR mutations in bronchial wash from Iraqi patients with NSCLC before treatment. Methods: DNA was extracted from bronchial wash samples collected from 50 patients with NSCLC by using a Qiamp DNA Mini Kit (Qiagen, Hilden, Germany). Then, EGFR mutations were determined by using real-time RCR combined with two technologies, Amplification Refractory Mutation System (
... Show MoreThe disposal of textile effluents to the surface water bodies represents the critical issue especially these effluents can have negative impacts on such bodies due to the presence of dyes in their composition. Biological remediation methods like constructed wetlands are more cost-effective and environmental friendly technique in comparison with traditional methods. The ability of vertical subsurface flow constructed wetlands units for treating of simulated wastewater polluted with Congo red dye has been studied in this work. The units were packed with waterworks sludge bed that either be unplanted or planted with Phragmites australis and Typha domingensis. The efficacy of present units was evaluated by monitoring of DO, Temperature, COD
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show More