Charge transfer (CT) at liquid/liquid interfaces are described theoretically depending on the quantum theory .A model that derived used to calculate the rate constant of transport at liquid/liquid interfaces. The calculation of the rate constant of charge transfer depends on the calculation of the reorganization energy, driving force ,and the coupling coefficient . Large reorganization energies and large rate constant for charge transfer ,indicate that the transitions involve more energy to happen . The system have large ð¸0 (ð‘’ð‘‰) refers that type of liquid is more reactive media than other liquid types with same donor. Driving force energy to drive the charge increases with the increase of absorption energy and decrease of in wave length. Height barrier at liquid/liquid interface that decreasing with decreasing the driving force energy and increasing the absorption energies .Charge transfer is so much small as a barrier of large values but in the low values of barrier ,the transfer is most probable. The large height barrier exclusion transfers across liquid/liquid system and the charger suffers from much resistant to transfer . However, this excluded transfer could be significantly large for high barrier and small concentrations .The theoretical values of rate constant of charge transfer show a good agreement with some of the experimental studies
In this paper, we built a mathematical model for convection and thermal radiation heat transfer of fluid flowing through a vertical channel with porous medium under effects of horizontal magnetic field (MF) at the channel. This model represents a 2-dimensional system of non-linear partial differential equations. Then, we solved this system numerically by finite difference methods using Alternating Direction Implicit (ADI) Scheme in two phases (steady state and unsteady state). Moreover, we found the distribution and behaviour of the heat temperature inside the channel and studied the effects of Brinkman number, Reynolds number, and Boltzmann number on the heat temperature behaviour. We solved the system by buildi
... Show MoreNumerical study is adapted to combine between piezoelectric fan as a turbulent air flow generator and perforated finned heat sinks. A single piezoelectric fan with different tip amplitudes placed eccentrically at the duct entrance. The problem of solid and perforated finned heat sinks is solved and analyzed numerically by using Ansys 17.2 fluent, and solving three dimensional energy and Navier–Stokes equations that set with RNG based k−ε scalable wall function turbulent model. Finite volume algorithm is used to solve both phases of solid and fluid. Calculations are done for three values of piezoelectric fan amplitudes 25 mm, 30 mm, and 40 mm, respectively. Results of this numerical study are compared with previous b
... Show MoreEvaporation from water bodies is important and considered a major problem in dry and semi-dry regions, in this research the evaporation has been analyzed from two approaches: engineeringly and statistically. The engineering approach deals with the calculation of evaporation rates of Mosul Dam Lake. Three methods were used: pan evaporation class A, the combined and the mass-transfer. It was found that the values obtained by pan evaporation class A method was the highest among the other, while the mass transfer method achieved the lowest results. The evaporation rates during the year ranged according to the first method (0.9–5.5) mm/day, second (0.7–11.5) mm/day and the last method (1.0039×106) m3/year, whi
... Show MoreA numerical investigation has been performed to study the effect of eccentricity on unsteady state, laminar aiding mixed convection in a horizontal concentric and eccentric cylindrical annulus. The outer cylinder was kept at a constant temperature
while the inner cylinder was heated with constant heat flux. The study involved numerical solution of transient momentum (Navier-Stokes) and energy equation using finite difference method (FDM), where the body fitted coordinate system (BFC) was
used to generate the grid mesh for computational plane. The governing equations were transformed to the vorticity-stream function formula as for momentum equations and to the temperature and stream function for energy equation.
A computer progra
Computer modeling has been used to investing the Coulomb coupling parameter ?. The effects of the structure parameter K, grain charge Z, plasma density N, temperature dust grain Td, on the Coulomb coupling parameter had been studied. It was seen that the ? was increasing with increasing Z and N, and decrease with increasing K and T. Also the critical value of ? that the phase transfer of the plasma state from liquid to solid was studied.
The charge density distributions (CDD) and the elastic electron scattering form
factors F(q) of the ground state for some odd mass nuclei in the 2s 1d shell, such
as K Mg Al Si 19 25 27 29 , , , and P 31
have been calculated based on the use of
occupation numbers of the states and the single particle wave functions of the
harmonic oscillator potential with size parameters chosen to reproduce the observed
root mean square charge radii for all considered nuclei. It is found that introducing
additional parameters, namely; 1 , and , 2 which reflect the difference of the
occupation numbers of the states from the prediction of the simple shell model leads
to very good agreement between the calculated an
The charge density distributions (CDD) and the elastic electron scattering form
factors F(q) of the ground state for some odd mass nuclei in the 2s 1d shell, such
as K Mg Al Si 19 25 27 29 , , , and P 31
have been calculated based on the use of
occupation numbers of the states and the single particle wave functions of the
harmonic oscillator potential with size parameters chosen to reproduce the observed
root mean square charge radii for all considered nuclei. It is found that introducing
additional parameters, namely; 1 , and , 2 which reflect the difference of the
occupation numbers of the states from the prediction of the simple shell model leads
to very good agreement between the calculated an
A mathematical model was proposed to study the microkinetics of esterification reaction of oleic acid with ethanol over prepared HY zeolite catalyst. The catalyst was prepared from Iraqi kaolin source and its properties were characterized by different techniques. The esterification was done under different temperature (40 to 70˚C) with 6:1 for molar ratio of ethanol to oleic acid and 5 % catalyst loading.
The microkinetics study was done over two period of time each period was examined individually to calculate the reaction rate constant and activation energy. The impact of the mass transfer resistance to the reactant was also investigated; two different studies have been accomplished to do this purpose.
&nb
... Show MoreIn the present work experiments were conducted to study the effect of solid loading (1,5 and 9 vol.%) on the enhancement of carbon dioxide absorption in bubble column at various volumetric gas flow rate (0.75, 1 and 1.5 m3/h) and absorbent concentration (caustic soda)( 0.1,0.5 and 1 M ). Activated carbon and alumina oxide (Al2O3) are used as solid particles. The Danckwerts method was used to calculate interfacial area and individual mass transfer coefficients during absorption of carbon dioxide in a bubble column. The results show that the absorption rate was increased with increasing volumetric gas flow rate, caustic soda concentration and solid loading. Mass transfer coefficient and interfac
... Show MoreIn the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi
... Show More