X-ray diffractometers deliver the best quality diffraction data while being easy to use and adaptable to various applications. When X-ray photons strike electrons in materials, the incident photons scatter in a direction different from the incident beam; if the scattered beams do not change in wavelength, this is known as elastic scattering, which causes amplitude and intensity diffraction, leading to constructive interference. When the incident beam gives some of its energy to the electrons, the scattered beam's wavelength differs from the incident beam's wavelength, causing inelastic scattering, which leads to destructive interference and zero-intensity diffraction. In this study, The modified size-strain plot method was used to examine the pattern of x-ray diffraction lines (101),(121),(202),(042), and (242) for calcium titanate(CaTiO3) nanoparticles in this study. To calculate the new variables, the size strain plot method was created., X-ray line analysis and calculation of crystal size and lattice tension of calcium titanate oxide nanoparticles. It is used to calculate the crystal volume (44.7 nm) and to calculate the determination of network parameters such as the texture modulus (Tc), macro stress (MS), specific surface area (SSA), and dislocation density(η), respectively.
Abstract
In this research provide theoretical aspects of one of the most important statistical distributions which it is Lomax, which has many applications in several areas, set of estimation methods was used(MLE,LSE,GWPM) and compare with (RRE) estimation method ,in order to find out best estimation method set of simulation experiment (36) with many replications in order to get mean square error and used it to make compare , simulation experiment contrast with (estimation method, sample size ,value of location and shape parameter) results show that estimation method effected by simulation experiment factors and ability of using other estimation methods such as(Shrinkage, jackknif
... Show MorePhysiological status and litter size can indeed have a significant impact on ewes' hematological parameters, which are essential indicators of their health. Therefore, this study examined the hematological profiles of ewes during pregnancy with single and twins in the Awassi ewes. The present study involved 232 ewes in good health and at sexual maturity. Among them, 123 ewes had single pregnancies, while 109 ewes had twin pregnancies. The age range of the ewes included in the study was between 3.5 and 4.5 years. Hematological tests were conducted on the sheep's blood samples promptly following collection. The findings demonstrated variations in hematological parameters among pregnant
... Show MoreIn this research, the focus was on estimating the parameters on (min- Gumbel distribution), using the maximum likelihood method and the Bayes method. The genetic algorithmmethod was employed in estimating the parameters of the maximum likelihood method as well as the Bayes method. The comparison was made using the mean error squares (MSE), where the best estimator is the one who has the least mean squared error. It was noted that the best estimator was (BLG_GE).
In this research the Empirical Bayes method is used to Estimate the affiliation parameter in the clinical trials and then we compare this with the Moment Estimates for this parameter using Monte Carlo stimulation , we assumed that the distribution of the observation is binomial distribution while the distribution with the unknown random parameters is beta distribution ,finally we conclude that the Empirical bayes method for the random affiliation parameter is efficient using Mean Squares Error (MSE) and for different Sample size .
The License Plate (LP), is a rectangular metal plate that contains numbers and letters. This plate is fixed onto the vehicle's body. It is used as a mean to identify the vehicle. The License Plate Recognition (LPR) system is a mean where a vehicle can be identified automatically using a computer system. The LPR has many applications, such as security applications for car tracking, or enforcing control on vehicles entering restricted areas (such as airports or governmental buildings). This paper is concerned with introducing a new method to recognize the Iraqi LPs using local vertical and horizontal projections, then testing its performance. The attained success rate reached 99.16%, with average recognition time around 0.012 second for re
... Show MoreThe aim of this paper is to present a method for solving of system of first order initial value problems of ordinary differential equation by a semi-analytic technique with constructing polynomial solutions for decreasing dangers of lead. The original problem is concerned using two-point osculatory interpolation with the fit equals numbers of derivatives at the end points of an interval [0 , 1].
The result of concentration varying of mixture methane with argon and neon gas are believed to study the change in electrons energy distribution function and then the change of the electrons transport parameters including the drift velocity, the mean energy, characteristics energy and diffusion coefficient. In the present work,a contemporary developed computer, simulation program known as Bolsig+ is being used for calculating the electron transport parameters.
In this paper, the maximum likelihood estimates for parameter ( ) of two parameter's Weibull are studied, as well as white estimators and (Bain & Antle) estimators, also Bayes estimator for scale parameter ( ), the simulation procedures are used to find the estimators and comparing between them using MSE. Also the application is done on the data for 20 patients suffering from a headache disease.
Radiotherapy is medical use of ionizing radiation, and commonly applied to the
cancerous tumor because of its ability to control cell growth.
The amount of radiation used in photon radiation therapy called dose (measured
in grey unit), which depend on the type and stage of cancer being treated.
In our work, we studied the dose distribution given to the tumor at different
depths (zero-20 cm) treated with different field size (4×4- 23×23 cm).
Results show that the deeper treated area has less dose rate at the same beam
quality and quantity. Also it has been noted increasing in the field increasing in the
depth dose at the same depth even if the radiation energy is constant. Increasing in
radiation dose attribut