Preferred Language
Articles
/
jih-2383
Assessment of Long Distance Chasing Photometer (NAG-ADF-300-2) by Estimating the Drug Atenolol with Povidone Iodine Via CFIA
...Show More Authors

     Atenolol was used with povidone iodine to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and povidone iodine in an aqueous medium. Optimum parameters was studied to increase the sensitivity development of method. Calibration graph was linear in the range of 2-19 mmol/L for cell A and 5-19 mmol/L for cell B. Limit of detection 146.4848 ng/55 µL and 2.6600 µg/200 µL respectively to cell A and cell  B. Correlation coefficient (r) 0.9957 for cell A and 0.9974 for cell. Relative standard deviation (RSD %) was lower than 1%, (n=8) for the determination of atenolol at concentration (5, 9 and 17) mmol/L for cell A and (5, 13 and 17) mmol/L for cell B respectively. The results were compared with classical method UV-spectrophotometric at λ max=270 nm by using method standard addition via t-test, at 95% confidence level. The comparison of data explain that long distance chasing photometer (NAG-ADF-300-2) is the choice with excellent extended detection and wide application.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2016
Journal Name
المجلة العربية للعلوم و نشر الأبحاث
Assessment of Carbonate Rocks , Western Desert of Iraq as Dimension Stones for Building
...Show More Authors

View Publication
Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Water Resources
Carcinogenic Risk Assessment of Trihalomethanes in Major Drinking Water Sources of Baghdad City
...Show More Authors

View Publication
Scopus (18)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Tue Apr 07 2020
Journal Name
Water Environment Research
Assessment of microbial contamination levels of water in hemodialysis centers in Baghdad, Iraq
...Show More Authors
Abstract<sec><label></label><p>Monitoring water quality in hemodialysis systems is extremely important to maintain adequate quality services for patients suffering from kidney failure. This work aims to examine and evaluate bacteriological characteristics and endotoxin contamination levels in hemodialysis water produced in dialysis centers. Forty‐eight water samples were collected and analyzed from four major hospitals in Baghdad for one year to evaluate seasonal effects. The analysis included the determination of total heterotrophic bacteria using the pour plate method, identification of bacterial isolate using the Vitek2 compact instrument, and the determination of endotoxins levels using Limulus ameboc</p></sec> ... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Permeability Estimation by Using the Modified and Conventional FZI Methods
...Show More Authors

There many methods for estimation of permeability. In this Paper, permeability has been estimated by two methods. The conventional and modified methods are used to calculate flow zone indicator (FZI). The hydraulic flow unit (HU) was identified by FZI technique. This technique is effective in predicting the permeability in un-cored intervals/wells. HU is related with FZI and rock quality index (RQI). All available cores from 7 wells (Su -4, Su -5, Su -7, Su -8, Su -9, Su -12, and Su -14) were used to be database for HU classification. The plot of probability cumulative of FZI is used. The plot of core-derived probability FZI for both modified and conventional method which indicates 4 Hu (A, B, C and D) for Nahr Umr forma

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Does the tertiary health care for Type 2 diabetic patients can help to Meet the recommended glycemic targets
...Show More Authors

Objectives: To study the effect of providing tertiary (specialized) health care for type 2 diabetic patients to meet the WHO and ADA standards and glycemic targets.
Method: Six months, Jan. – Jun. 2010, cohort study was conducted on 600 adult diabetics who registered in the National Diabetes Center (NDC) / Al-Mustansiriya University, Baghdad – Iraq. They were followed for 3- 6 months; each time patients were examined physically and their blood pressure, height, weight and BMI were measured. Fasting blood samples were taken from all patients to test the FPG, HbA1c, T.Chol, TG, HDL and LDL.
Results: Patients’ age was 52.85±15.56 year and the male/female ratio was 1.01, the median duration of disease was 7 years and their BMI w

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Al-nahrain Journal Of Science
Spectrophotometric Determination of Co(II) in Vitamin B12 Using2-(biphenyl-4-yl)-3-((2-(2,4-dinitrophenyl) hydrazono)methyl) imidazo [1,2-a]pyridine as Ligand by Flow Injection–Merging Zone Analysis
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Tue Jun 27 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluating the Benefits of Using Mobile Application (diarrhea management step by step) in the Management of Diarrhea by Community Pharmacists
...Show More Authors

Diarrhea is one of the most commonly encountered minor ailments in the community pharmacies. It is associated with significant morbidity and mortality. However, the majority of pharmacists in Iraq did not manage diarrheal cases in a proper way. Therefore, the current study aimed to evaluate the benefit of a new mobile application (diarrhea management step by step) to improve the pharmacist's role in the management of diarrhea. The study was conducted from 21th September to 21th October 2021 using a pre-post design via a simulated patient (SP) technique. A validated diarrhea scenario was presented to each pharmacist by the SP twice, once before and the other after giving the mobile application to the pharmacist. Furthermore, pharmaci

... Show More
Scopus (2)
Scopus Crossref
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of [Benzyl (2-hydroxy-1naphthylidene) hydrazine carbodithioate] and Its Metal Complexes With [Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)] Ions
...Show More Authors

  The formation of  Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)-complexes (C1-C5) respectively was studied with new Schiff base ligand [benzyl(2-hydroxy-1-naphthalidene) hydrazine carbodithioate  derived from reaction of  2-hydroxy-1-naphthaldehyde and benzyl hydrazine carbodithioate. The suggested structures of the ligand and its complexes have been determined   by using C.H.N.S analyzer, thermal analysis, FT-IR, U.V-Visible, 1HNMR, 13CNMR , conductivity measurement , magnetic susceptibility and atomic absorption. According to these studies,  the ligand coordinates as  a tridentate with metal ions through nitrogen atom of azomethane , oxygen atom of  hydroxyl, and  sulfur atom of thione  

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of [Benzyl (2-hydroxy-1naphthylidene) hydrazine carbodithioate] and Its Metal Complexes With [Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)] Ions
...Show More Authors

   The formation of  Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)-complexes (C1-C5) respectively was studied with new Schiff base ligand [benzyl(2-hydroxy-1-naphthalidene) hydrazine carbodithioate  derived from reaction of  2-hydroxy-1-naphthaldehyde and benzyl hydrazine carbodithioate. The suggested structures of the ligand and its complexes have been determined   by using C.H.N.S analyzer, thermal analysis, FT-IR, U.V-Visible, 1HNMR, 13CNMR , conductivity measurement , magnetic susceptibility and atomic absorption. According to these studies,  the ligand coordinates as  a tridentate with metal ions through nitrogen atom of azomethane , oxygen atom of  hydroxyl, and  sulfur atom of thione

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 23 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Impact of self-assessment on income and sales tax collections from the point of view of income tax auditors in Jordan
...Show More Authors

This study aimed to show the extent of compliance with the income taxpayer  to provide tax returns and increase the speed of collection of these taxes in addition to increasing confidence in  Income Tax department and reduce the number of cases transferred to the courts and promote taxpayer awareness in charge of the importance of system self-assessment, and study sought to investigate the effect of the existence of records documents, technical audit, and computational audit and documentary audit on income tax collections in Jordan, from the point of view of Jordanian income tax auditors ,results shows there's a strong  relation between these variables and Income Tax collections.

View Publication Preview PDF