Preferred Language
Articles
/
jih-2383
Assessment of Long Distance Chasing Photometer (NAG-ADF-300-2) by Estimating the Drug Atenolol with Povidone Iodine Via CFIA
...Show More Authors

     Atenolol was used with povidone iodine to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and povidone iodine in an aqueous medium. Optimum parameters was studied to increase the sensitivity development of method. Calibration graph was linear in the range of 2-19 mmol/L for cell A and 5-19 mmol/L for cell B. Limit of detection 146.4848 ng/55 µL and 2.6600 µg/200 µL respectively to cell A and cell  B. Correlation coefficient (r) 0.9957 for cell A and 0.9974 for cell. Relative standard deviation (RSD %) was lower than 1%, (n=8) for the determination of atenolol at concentration (5, 9 and 17) mmol/L for cell A and (5, 13 and 17) mmol/L for cell B respectively. The results were compared with classical method UV-spectrophotometric at λ max=270 nm by using method standard addition via t-test, at 95% confidence level. The comparison of data explain that long distance chasing photometer (NAG-ADF-300-2) is the choice with excellent extended detection and wide application.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 30 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Indirect Way for the Assay of Captopril Drug in Dosage FormsUsing1,10-Phenanthroline as a Selective Spectrophotometric Agent for Fe(II) Via Homemade CFIA /Merging Zones Technique
...Show More Authors

        A new speed and sensitive batch and merging zones-flow injection analysis spectrophotometric ways for estimation of captopril in a fine material and in pharmaceutical formulations were suggested. The procedure was depended on the  decline of Fe(III) as FeCl3 to Fe(II) by captopril in acetic acid as medium, the produced Fe(II) interplays with 1,10-phenanthroline to compose a soluble orange-red colored product that is determined at maximum wave length of 511nm. The manifold FIA system was able to determine of CPL. with a throughput 51 sample/h. Calibration curves of absorbance against concentration sign of that Beer, s law is submitted to within the concentration scale o

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Economics And Administrative Sciences
Fuzzy Bridge Regression Model Estimating via Simulation
...Show More Authors

      The main problem when dealing with fuzzy data variables is that it cannot be formed by a model that represents the data through the method of Fuzzy Least Squares Estimator (FLSE) which gives false estimates of the invalidity of the method in the case of the existence of the problem of multicollinearity. To overcome this problem, the Fuzzy Bridge Regression Estimator (FBRE) Method was relied upon to estimate a fuzzy linear regression model by triangular fuzzy numbers. Moreover, the detection of the problem of multicollinearity in the fuzzy data can be done by using Variance Inflation Factor when the inputs variable of the model crisp, output variable, and parameters are fuzzed. The results were compared usin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
Estimating the Reliability Function of (2+1) Cascade Model
...Show More Authors

This paper discusses reliability R of the (2+1) Cascade model of inverse Weibull distribution. Reliability is to be found when strength-stress distributed is inverse Weibull random variables with unknown scale parameter and known shape parameter. Six estimation methods (Maximum likelihood, Moment, Least Square, Weighted Least Square, Regression and Percentile) are used to estimate reliability. There is a comparison between six different estimation methods by the simulation study by MATLAB 2016, using two statistical criteria Mean square error and Mean Absolute Percentage Error, where it is found that best estimator between the six estimators is Maximum likelihood estimation method.

View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
The Egyptian Journal Of Hospital Medicine
Effect of Radioactive Iodine Therapy on Interleukin-2 (IL-2), IL-17 and Physiological Parameters in Iraqi Patients with Graves’ Disease
...Show More Authors

View Publication
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
A New Approach for Developing Spectrophotometric Determination of Phenylephrine Drug in Pure, Pharmaceutics and Serum Samples Using Sodium Periodate as Oxidizing Agent via a Green Method of CFIA/Merging Zone Technique
...Show More Authors

     The research involved a rapid, automated and highly accurate developed CFIA/MZ technique for estimation of phenylephrine hydrochloride (PHE) in pure, dosage forms and biological sample. This method is based on oxidative coupling reaction of 2,4-dinitrophenylhydrazine (DNPH) with PHE in existence of sodium periodate as oxidizing agent in alkaline medium to form a red colored product at ʎmax )520 nm (. A flow rate of 4.3 mL.min-1 using distilled water as a carrier, the method of FIA proved to be as a sensitive and economic analytical tool for estimation of PHE.

Within the concentration range of 5-300 μg.mL-1, a calibration curve was rectilinear, where the detection limit was 3.252 μg.mL

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Preparation and Purification of natural uranium metal by Iodine method.
...Show More Authors

In this work ,glass-metal apparatus was designed and manufactured which used for preparing ahigh purity uranium. The reaction is simply take place between iodine vapour and uranium metal at 500C in closed system to form uranium tetra iodide which is decomposed on hot wire at high temperature around 1100C. Also another apparatus was made from Glass and used for preparing ahigh purity of UI4 more than 99.9% purity.

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Malaysian Journal Of Science
SIMPLEX OPTIMIZATION FOR THE SPECTROPHOTOMETRIC DETERMINATION OF AZITHROMYCIN DRUG VIA ION-PAIR FORMATION
...Show More Authors

A spectrophotometric determination of azithromycin was optimized using the simplex model. The approach has been proven to be accurate and sensitive. The analyte has been reacted with bromothymol blue (BTB) to form a colored ion pair which has been extracted in chloroform in a buffer medium of pH=4 of potassium phthalate. The extracted colored product was assayed at 415 nm and exhibited a linear quantification range over (1 - 20) g/ml. The excipients did not exhibit any interferences with the proposed approach for assaying azithromycin in pharmaceutical formulations.

View Publication
Scopus
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Measurement of the distance to the central stars of Nebulae by using Expansion methods with Alladin Sky Atlas
...Show More Authors
Abstract<p>The usual methods of distance determination in Astronomy parallax and Spectroscopic with Expansion Methods are seldom applicable to Nebulae. In this work determination of the distances to individual Nebulae are calculated and discussed. The distances of Nebulae to the Earth are calculated. The accuracy of the distance is tested by using Aladin sky Atlas, and comparing Nebulae properties were derived from these distance made with statistical distance determination. The results showed that angular Expansions may occur in a part of the nebulae that is moving at a velocity different than the observed velocity. Also the results of the comparison of our spectroscopic distances with the trig</p> ... Show More
View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of the Nurse’s Role Regarding drug Administration of Cardiovascular Patients
...Show More Authors

Objectives: The aim of the study was, to assess the nurse's role regarding cardiovascular drug
administration in Erbil city.
Methodology: A descriptive survey was conducted in Hawler teaching and Rizgari teaching Hospitals. The
number of samples is 50 nurses; the period of the study was started from 15th of November 2008 up to
the end of March 2009. A questionnaire was developed by investigators based on extensive review of
available studies and literatures. Data were collected through application of observational check list
consist of two part, part one was demographic sheet and part two about nurse’s responsibility regarding
medication administration which include (before, during, after drug administration). Data

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Dna Repair
The interactions between DNA methylation machinery and long non-coding RNAs in tumor progression and drug resistance
...Show More Authors

DNA methylation is one of the main epigenetic mechanisms in cancer development and progression. Aberrant DNA methylation of CpG islands within promoter regions contributes to the dysregulation of various tumor suppressors and oncogenes; this leads to the appearance of malignant features, including rapid proliferation, metastasis, stemness, and drug resistance. The discovery of two important protein families, DNA methyltransferases (DNMTs) and Ten-eleven translocation (TET) dioxygenases, respectively, which are responsible for deregulated transcription of genes that play pivotal roles in tumorigenesis, led to further understanding of DNA methylation-related pathways. But how these enzymes can target specific genes in different malignancies;

... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref