Preferred Language
Articles
/
jih-1167
Total luminescence (Chemiluminescence & Fluorescence)- FIA Method For The Determination of DL-Histidine
...Show More Authors

Histidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to  initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significant difference and both equations can be used to represent the data obtained 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Apr 10 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified with Functionalized Graphene Oxide
...Show More Authors

Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×

... Show More
Preview PDF
Publication Date
Mon Jun 10 2019
Journal Name
Chemistry &chemical Technology
Quantitative Determination of Ephedrine Hydrochloride in Pharmaceutical Injections by Highly Sensitive Turbidimetric and Reversed-Phase Combined with UFLC Methods
...Show More Authors

In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Thu May 17 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified With Functionalized Graphene Oxide
...Show More Authors

  Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial ( GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration  of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Determination of hepcidin (25) level in hemodialysis Iraqi male patients and its relation with erythropoietin and some biochemical parameters
...Show More Authors

Background: Anemia is a common finding in patients with renal failure disease and it is, primarily, due to reduced production of iron and erythropoietin. Therefore, the aim of current study was to evaluate the relationship between serum level of hepcidin 25, on the one hand, and levels of serum iron, total iron-binding capacity, serum erythropoietin and transferrin saturation% in Iraqi male patients undrgoning haemodialysis.. Methods: Serum from75 males in the end stage of hemodialysis, as group one, and 25 Iraqi healthy malecontrols, as group two, were recruited in this study. Results: Data from current study showed significant increase in hepcidin 25 and significant decrease in serum iron, total iron-binding capacity, transferrin saturati

... Show More
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Chromium (VI) Removal from Wastewater by Electrocoagulation Process Using Taguchi Method: Batch Experiments
...Show More Authors

Electrocoagulation is an electrochemical method for treatment of different types of wastewater  whereby sacrificial anodes corrode to release active coagulant (usually aluminium or iron cations) into solution, while simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation or settling. The Taguchi method was applied as an experimental design and to determine the best conditions for chromium (VI) removal from wastewater. Various parameters in a batch stirred tank by iron metal electrodes: pH, initial chromium concentration, current density, distance between electrodes and KCl concentration were investigated, and the results have been analyzed using signal-to-noise (S/N) ratio. It was found that the r

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 02 2013
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Images Segmentation Based on Fast Otsu Method Implementing on Various Edge Detection Operators
...Show More Authors

Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Carbon Nanotubes: Synthesis via Flame Fragment Deposition (FFD) Method from Liquefied Petroleum Gas
...Show More Authors

The current study uses the flame fragment deposition (FFD) method to synthesize carbon nanotubes (CNTs) from Iraqi liquefied petroleum gas (LPG), which is used as a carbon source. To carry out the synthesis steps, a homemade reactor was used. To eliminate amorphous impurities, the CNTs were sonicated in a 30 percent hydrogen peroxide (H2O2) solution at ambient temperature. To remove the polycyclic aromatic hydrocarbons (PAHs) generated during LPG combustion, sonication in an acetone bath is used. The produced products were investigated and compared with standard Multi-walled carbon nanotube MWCNTs (95%), Sigma, Aldrich, using X-ray diffraction (XRD), thermo gravimetric analysis (TGA), Raman spectroscopy, scanning el

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Petroleum Research And Studies
Stress Ratio Method to Predict Fracture Pressure Gradient in Southern Iraqi Deep Wells
...Show More Authors

This research presents a method for calculating stress ratio to predict fracture pressure gradient. It also, describes a correlation and list ideas about this correlation. Using the data collected from four wells, which are the deepest in southern Iraqi oil fields (3000 to 6000) m and belonged to four oil fields. These wells are passing through the following formations: Y, Su, G, N, Sa, Al, M, Ad, and B. A correlation method was applied to calculate fracture pressure gradient immediately in terms of both overburden and pore pressure gradient with an accurate results. Based on the results of our previous research , the data were used to calculate and plot the effective stresses. Many equations relating horizontal effective stress and vertica

... Show More
Publication Date
Wed Aug 28 2024
Journal Name
Mesopotamian Journal Of Cybersecurity
A Novel Anomaly Intrusion Detection Method based on RNA Encoding and ResNet50 Model
...Show More Authors

Cybersecurity refers to the actions that are used by people and companies to protect themselves and their information from cyber threats. Different security methods have been proposed for detecting network abnormal behavior, but some effective attacks are still a major concern in the computer community. Many security gaps, like Denial of Service, spam, phishing, and other types of attacks, are reported daily, and the attack numbers are growing. Intrusion detection is a security protection method that is used to detect and report any abnormal traffic automatically that may affect network security, such as internal attacks, external attacks, and maloperations. This paper proposed an anomaly intrusion detection system method based on a

... Show More
View Publication
Scopus (2)
Scopus Crossref