Wires are commonly used for the construction of orthodontic appliances and occasionally as wrought clasps and rests on partial dentures. The corrosion resistance is the most important properties of dental alloy. Corrosion process reported to cause a numerous adverse effects on both living tissue and restoration .The conditions in the mouth are very suitable for the occurrence of corrosion. The main objective of this study was to evaluate the corrosion behavior of different gauges of stainless steel wire in artificial saliva .Four gauges of dental stainless steel wire used in orthodontic and removable partial denture were used in this study 0.6mm.,0.7mm.,0 .8mm.&1.0mm.).The specimens were divided according to gauge in to four groups(A,B,C,&D ) ,ten specimens in each group .Each wire was cut by using wire cutter to get wire with (1cm) in length .Artificial saliva of Fusayama Meyer type was used as the testing solution .Sensitive electronic balance was used to weight the sample before immersion in solution and recording the results.This this represents the first weight(W1).Each specimen was put inside a test tube , and held using dental floss in a way that the specimen was fully immersed in the solution from all sides . The specimens then were put inside an incubator ,which was adjusted at 37±2 and left for 14 days .At the end of immersion period ; the specimens were removed from the solution and then allowed to dry and were balanced then the results were recorded .This represents the second weight (W2) .After obtaining the (W1)&(W2) the corrosion rate was calculated . The results before and after immersion showed that the 0.6 mm.& 0.7mm stainless steel wire gave the highest and more corrosion resistance value than 0.8mm&1.0mm.stainless steel wire . The result showed there is a statistical significance between (W1&W2) of 0.8mm stainless steel wire and highly significant between (W1&W2) of 1.0mm. stainless steel wire . The comparison of the results after calculating results in corrosion rate formula showed that the 1.0mm stainless steel wire more corrosion resistance followed by 0.8mm wire ,from 0.6mm& 0.7 mm wire .
Background: The mechanical properties of 3D-printed denture base resins are crucial factors for determining the quality and performance of dentures inside a patient’s mouth. Tensile strength and diametral compressive strength are two properties that could play significant roles in assessing the suitability of a material. Although they measure different aspects of material behavior, a conceptual link exists between them in terms of overall material strength and resilience. Aim: This study aims to investigate the correlation between tensile strength and diametral compressive strength after incorporating 2% ZrO2 nanoparticles (NPs) by weight into 3D-printed denture base resin. Methods: A total of 40 specimens (20 dumbbell-shaped and
... Show MoreAbstract
The methods of the Principal Components and Partial Least Squares can be regard very important methods in the regression analysis, whe
... Show MoreGod Almighty set out to build mosques, and he commanded to seek their architecture, and the competition for them, and allocate them with types of worship that are not valid in others, and to preserve their sanctity and not to be degraded and taken for mundane purposes and special benefits, because they are considered one of the most prominent features of Islam and the rituals of Islamic society, so this research came to show the rule Sharia in various and contemporary issues that are needed by the imams of the mosques, their rulers, and those responsible for them. Among the issues in which they have examined comparative juristic research and reached the most correct opinion are:
Building mosques over or under buildings and factories i
The research involves examining the influence of partial solar eclipse on the strength of neutral hydrogen from the Sun. Baghdad University Radio Telescope (BURT) was used to monitor the partial solar eclipse on the 25th of October, 2022. Radio observations from the Sun were recorded from 11:30 AM to 03:36 PM. This means that the HI emission from the Sun was recorded before, during and after the event. It was noticed, that at the moment of maximum eclipse, ~ 46% of the Sun’s disk was covered by the Moon. For the purpose of this research, the solar radio wave intensity was monitored and the solar flux density was determined at different times, i.e. before, during and after the partial solar eclipse. The obtained results showed that
... Show MoreLeucine aminopepotidase (LAP)[EC:3.4.11.1] activity has been assayed in (50) serum samples of patients with diabeties naphrophathy D.N (non-insulin dependent diabetic (NIDD) , and (50)serum sample of healthy individuals without any clinically detectable diseases have been as control group. The aim of this study is to measure leucine aminopeptidase activity and partially purifying the enzyme from sera of patients with diabetes nephropathy The results of this study revealed that Leucine aminopeptidase (LAP) activity of nephropathy patient’s serum shows a high signifiacant increase (p < 0.001) compared to that of the healthy subjects.LAP was purified from the serum of patients with diabetes nephropathy by dialysis and gel filtration (Se
... Show MoreAbstract
This study investigated the optimization of wear behavior of AISI 4340 steel based on the Taguchi method under various testing conditions. In this paper, a neural network and the Taguchi design method have been implemented for minimizing the wear rate in 4340 steel. A back-propagation neural network (BPNN) was developed to predict the wear rate. In the development of a predictive model, wear parameters like sliding speed, applying load and sliding distance were considered as the input model variables of the AISI 4340 steel. An analysis of variance (ANOVA) was used to determine the significant parameter affecting the wear rate. Finally, the Taguchi approach was applied to determine
... Show MoreThis research focuses on improvement of the corrosion behaviour of commercial pure titanium (Ti) grade II when exposed to Hank’s solution through different surface treatments. The disc shape of titanium samples were constructed to be divided according to their surface treatment. The first experimental group the Ti sample was exposed to computer numerical control (CNC) fiber laser machine. Whereas, the other experimental group the Ti sample was only coated with Polyetherketon keton (PEKK) by using carbon dioxide (CO2) laser technique while the last experimental group the Ti sample was treated with CNC fiber laser followed by PEKK coating by using CO2 laser technique. All were compared with the untreated control group. The electrochemical a
... Show MoreThis study aims to recognize the process of using computer in publicschools in Ma`an governorate in terms of hardware, capabilities, and teachers usage. It also aims to identify the most important obstacles those schools face from a teachers perspective.
The study sample consists of (150) teachers from different disciplines. The researcher prepared two questionnaires related to the research pivotal, then presented to a group of arbitrators to be used in this final form. The data was analyzed statistically and the study concluded that there is a shortage in the computer services provided to teachers, and there is a w
... Show MoreAdaptive responses in larval behavior may be of two kinds: Taxis: This involves a change in direction relative to source of a stimulus. Kinesis: Kinesis has no directional component, but involves change in the rate of performance in response to a stimulus. Drosophila larvae exhibited flexible behavioral responses associated with food acquisition and selection for different environmental conditions. In this investigation, we are concerned explosively with kinetic responses to food viability. Third instar larvae were subjected to test for thirty minutes in each of the following conditions i) in distilled water, ii) in Ringer's solution, iii) in glucose solution and on live yeast suspension. In each case the larva was in a thin layer of solu
... Show More