Abstract :
The habitat type and food availability always influence the population size of many
organisms. Bird’s feeding pattern should be abstracted to complete avian community structure
data. The agronomy main research farm of Orissa University of Agriculture and Technology
is a well-managed multi-crop agro-ecosystem which provides a suitable ground for ecological
research. In a multi-crop farmland, the association of Barn Swallow Hirundo rustica Linnaeus,
1758, with the Indian mustard Brassica juncea (L.) Czernajew, 1859 crops have been
recorded for the first time while hovering only on this field. A flock of Barn swallows was
recorded in 32 field visits while flying continuously over the Indian mustard field after
flow
Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl
... Show MoreIn the present work, radium (226Ra), thorium (232Th), potassium (40 K), and cesium (137Cs) (Bq/kg) was measured for 24 soil samples of some districts of Al-Doura city in Baghdad governorate. The gamma spectrometry method with NaI (Tl) detector was used for radiometric measurements. The average values of specific activity for 226Ra, 232Th, 40K and 137Cs in soil samples were 38.03, 42.48, 16.34 and 2.76 Bq/kg, respectively. The radiation indicators were measured and the average values recorded were 100 Bq/kg, 44.6 nGy/h, 0.27 Bq/kg, 0.373 Bq/kg, 0.219 mSv/y, 0.055 mSv/y and 0.689 Bq/kg for the parameters of radium equivalent act
... Show More
يتناول البحث الحالي احد الاساليب المعروفة والمستخدمة في تحليل الاسهم بصورة منفردة او ضمن (قطاعاتها الصناعية) الا وهو اسلوب تحليل القوة النسبية.
ولاثبات فرضية البحث تم اختيار سوق العراق للاوراق المالية لكي يكون مجتمعا للبحث، ومن ثم اختيار عينة عمدية مؤلفة من ثلاثة عشر سهما من اسهم الشركات المدرجة في هذه السوق لتكون ميدانا للبحث.
توصل البحث الى عدد من الاستنتاجات، الا ان اكثر
... Show MoreThere are many economic issues that concern society at the local and international levels and which constitute a serious challenge to the societies and governments , perhaps including the issue of corruption in all its forms and manifestations and effects , which now attract the attention the issue of human society everywhere .
... Show MoreA new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla
... Show MoreCo(II) ion was determined by a new, accurate, sensitive and rapid method via a
continuous flow injection analysis (CFIA) with a chemiluminescence reaction based on
the oxidation of Luminol which is loaded on poly acrylic acid gel beads by hydrogen
peroxide in presence of Cobalt (II) ion as a chemiluminescence catalyst. Chemical and
physical parameters were investigated to obtain the best conditions. Linear dynamic
range of Cobalt (II) ion was from 0.1-20.0 μg.ml-1 with a correlation coefficient r =
0.9758, limit of detection (L.O.D) 0.2 ng/sample from the step wise dilution of lowest
concentration in the calibration graph with the percentage relative standard deviation for
3 μg.ml-1 Co(ll) solution is 0.8537% (n