Preferred Language
Articles
/
jeasiq-1710
Some Estimation methods for the two models SPSEM and SPSAR for spatially dependent data
...Show More Authors

ABSTRUCT

In This Paper, some semi- parametric spatial models were estimated, these models are, the semi – parametric spatial error model (SPSEM), which suffer from the problem of spatial errors dependence, and the semi – parametric spatial auto regressive model (SPSAR). Where the method of maximum likelihood was used in estimating the parameter of spatial error          ( λ ) in the model (SPSEM), estimated  the parameter of spatial dependence ( ρ ) in the model ( SPSAR ), and using the non-parametric method in estimating the smoothing function m(x) for these two models, these non-parametric methods are; the local linear estimator (LLE) which require finding the smooth parameter ( h ) according to the cross validation criterion ( CV ), the Local linear two step estimator  after removing the effect of the spatial errors dependence , once using variance- covariance spatial matrix of errors ( Ω )using kernel function(LLEK2) and other through the use of variance- covariance spatial matrix of errors ( Ω* ) using cubic B-Spline estimator (LLECS2), to remove the effect of the spatial errors dependence, also the Local linear two step estimator using Suggested kernel estimator, once using variance- covariance spatial matrix of errors using kernel estimator (SUGK2), and other through the use of variance- covariance spatial matrix of errors using cubic B-Spline estimator (SUGCS2) to removing the effect of the spatial errors dependence.

From the simulation experiment, with a frequency of 1000 times, for three sample sizes, three levels of variance, for two model, and Calculate the matrix of distances between the sites of the observations through the Euclidean distance, the two estimated methods mentioned above were used to estimate (SPSEM) and (SPSAR) models, using the spatial Neighborhoods matrix modified under the Rook Neighboring criteria. Comparing these methods using mean absolute percentage error (MAPE) turns out that the best method for the SPSEM) model is (SUGCS2) method, and for (SPSAR) model is (LLECS2) method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Volterra Runge- Kutta Methods for Solving Nonlinear Volterra Integral Equations
...Show More Authors

In this paper Volterra Runge-Kutta methods which include: method of order two and four will be applied to general nonlinear Volterra integral equations of the second kind. Moreover we study the convergent of the algorithms of Volterra Runge-Kutta methods. Finally, programs for each method are written in MATLAB language and a comparison between the two types has been made depending on the least square errors.

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Different methods for characterizing surface roughness using laser speckle technique
...Show More Authors

In this work, results from an optical technique (laser speckle technique) for measuring surface roughness was done by using statistical properties of speckle pattern from the point of view of computer image texture analysis. Four calibration relationships were used to cover wide range of measurement with the same laser speckle technique. The first one is based on intensity contrast of the speckle, the second is based on analysis of speckle binary image,  the third is on size of speckle pattern spot, and the latest one is based on characterization of the energy feature of the gray level co-occurrence matrices for the speckle pattern. By these calibration relationships surface roughness of an object surface can be evaluated within the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
FIA– Spectrophotometric methods for the determination of Naringenin in supplements and urine samples using diazotization coupling reactions
...Show More Authors

Direct FIA methods for estimation of Naringenin (NG) in different samples were proposed. These methods are based on diazotization coupling reactions of two reagents: method (A) p-chloroaniline (PCA) and method (B) procaine hydrochloride (PRH) with NG in basic medium. Yellow dyes with maximum absorption at 416 and 415 nm were formed respectively. Calibration curves were constructed over different NG concentrations, linearity was from 1- 70 and 1- 40 µgmL-1 with detection limits of 0.55 and 0.24 µgmL-1 for (A) and (B) respectively. All analytical variables involved in the FIA procedure were evaluated and optimized. The established methods were successfully applied for the determination of NG in its supplements and u

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
A Comparison between Methods of Laplace Estimators and the Robust Huber for Estimate parameters logistic regression model
...Show More Authors

The logistic regression model regarded as the important regression Models ,where of the most interesting subjects in recent studies due to taking character more advanced in the process of statistical analysis .                                                

The ordinary estimating methods is failed in dealing with data that consist of the presence of outlier values and hence on the absence of such that have undesirable effect on the result.    &nbs

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Synthesis of some polyimides by different methods
...Show More Authors

in this work the polymides were prepared as rthemally stable polymers by diffrent ways

View Publication Preview PDF
Crossref
Publication Date
Sat Jul 08 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Estimation of Superoxide Dismutase, Matrix-metalloprotinase-9, and Interleukin -18 in Patients with Type Two Diabetes Mellitus
...Show More Authors

Antioxidant status imbalance and inflammatory process are cooperative events involved in type 2 diabetes mellitus. This study aimed to investigate     superoxide dismutase as a potential biomarkers of antioxidant imbalance, matrix-metaloprotinase-9,   and interleukin -18  as biomarkers of inflammation in serum and to estimate  the effects of other confounding factors  gender, age and finally measuring the relation among the interested biomarkers.

This case - control study included 50 patients,   and   45 of  healthy subjects matched age –gender were also enrolled  in this study as a control group.    The   focused &nbsp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 30 2019
Journal Name
Journal Of The College Of Education For Women
The General Principles of The Curriculum In Some Manuscripts Arab And Muslim Scholars
...Show More Authors

Our scientists Arabs old efforts in achieving texts that led to the foundations of general
rules they have set for this work in accordance with the systematic context is based on the
study, analysis and precision in dealing with this work, which became the basis for each
investigator to the present day, which was to them careful consideration manuscripts and
work to be closer to the image by its author, so produced their efforts in this area several
books provided the technical wizards of this science, which did not leave a gap in which only
gave her treatments and suggestions each and every one of the point made by and gave her
what produced the expertise in this direction in accordance with the formulations
meth

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 25 2021
Journal Name
International Journal Of Drug Delivery Technology
Comparison among the Synthesis of Some Azomethine Derivatives by Classical and Non-classical Methods
...Show More Authors

In this time, most researchers toward about preparation of compounds according to green chemistry. This research describes the preparation of 2-fluoro-5-(substituted benzylideneamino) benzonitrile under reflux and microwave methods. Six azomethine compounds (B1-6) were synthesized by two methods under reflux and assisted microwave with the comparison between the two methods. Reflux method was prepared of azomethine (B1-6) by reaction of 5-amino-2-fluorobenzonitrile with some aldehyde derivatives with (50–100) mL of absolute ethanol and some quantity of GAA and time is limited between (2–5) hours with a yield between (60–70) percent with recrystallization for appropriate solvents. But the microwave-assisted method was synthesized of co

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
International Journal Of Drug Delivery Technology
Comparison among the Synthesis of Some Azomethine Derivatives by Classical and Non-classical Methods
...Show More Authors

Preview PDF
Publication Date
Wed Nov 24 2021
Journal Name
International Journal Of Drug Delivery Technology
Comparison among the Synthesis of Some Azomethine Derivatives by Classical and Non-classical Methods
...Show More Authors

الوصف In this time, most researchers toward about preparation of compounds according to green chemistry. This research describes the preparation of 2-fluoro-5-(substituted benzylideneamino) benzonitrile under reflux and microwave methods. Six azomethine compounds (B1-6) were synthesized by two methods under reflux and assisted microwave with the comparison between the two methods. Reflux method was prepared of azomethine (B1-6) by reaction of 5-amino-2-fluorobenzonitrile with some aldehyde derivatives with (50–100) mL of absolute ethanol and some quantity of GAA and time is limited between (2–5) hours with a yield between (60–70) percent with recrystallization for appropriate solvents. But the microwave-assisted method was synthe

... Show More
Scopus (3)
Scopus