The study of the laptop computer table is one of the important studies at the present time due to the importance of electronic computers that are used in work sites and homes for very long hours, so one of the most important basics of caring for the comfort of the user lies in the design of the laptop table in different shapes and sizes and multiple functions in addition to calculating the measurements of the human body and the extent Its compatibility with the design and measurements of laptop computer tables by taking into account the calculations and measurements of the dimensions of the user's body of all ages and their consistency and use with the general measurements of the tables and the importance of research comes through the establishment of a knowledge base covering the topic of research to be of benefit to designers and specialists in this field and of benefit to product users as this study is It included all aspects of the tables, and the aim of this study was: to find foundations for building the formal system for the laptop table to be more suitable for the user. As for the limits of the research, the study of the formal system for the laptop table of the Chinese company Havic and available in the Iraqi market during the year 2011-2012 This study contains four chapters, the first chapter includes the research problem and the need for it in addition to oh The amount of research and its objectives and limits. As for the second chapter, it included the previous studies and the theoretical framework, which in turn contained three topics, the first was titled Foundations of Building the Formal System for the Laptop Desk and it contained an overview of the laptop computer, the laptop table, the system, the shape, and the second topic was titled Multifunctionality of the Laptop Table The third topic is on the mechanism of the human body ergonomics and its relationship to the laptop table. And then this chapter ended with indicators. The third chapter includes research procedures and methodology, and includes description and analysis of sample samples according to the axes analysis form. Finally, the fourth chapter included the results of the analysis, conclusions, recommendations and proposals. 1. The design system was distinguished by the efficiency of the functional performance and it helped in that the flat and supportive surface of the table surface in addition to the mechanism of the movement of the legs up and down as well as laterally and this achieved a distinct performance aspect although there were no fans for cooling The laptop computer while working and this was achieved in Form No. (1) and the percentage was 50%, while Model No. (2) achieved higher efficiency in functionality due to the presence of fans and the percentage was 50% .2 The dimensions of the computer tables differed according to the user’s need, as they were voluntary To the user as he wants through the size of the table tops and its inclination mechanism in addition to controlling the height and drop of the table legs. 3 The interconnectedness between the design parts aims to influence the functionality in a good way and this was achieved through the use of appropriate fastening means for the mechanism of movement and movement of the table by 50%
The research aims to achieve a set of the most important objectives of the review of the role of creative administrative leadership in achieving aspects of economic reform in various government institutions and indicate the role of supervisory awareness of administrative leadership in the revitalization of the role of the internal control system to achieve the best use of available resources. This paper deals with three problems is the loss of financial resources of the state as a result of the growing phenomenon of administrative and financial corruption in the majority of government institutions, and the weakness of the role of the internal control system in the province on the resources available and to achieve the best use of these reso
... Show MoreThe aim of our current study was to identify the effect of particulate matter of both types (PM2.5 and PM10) resulting from hookah smoking on the hemopoietic system of workers (smokers) in closed cafes. This study included six stations (cafes) on the Rusafa side of Baghdad city and conducted a blood test that included a complete blood count (CBC). A multifunctional air quality detector measured both types of particulate matter in the morning and evening. The study included 30 men (workers and smokers) and 30 men (non-smokers), whose ages ranged from 20 to 40 years. The study found that smokers had an increase in white blood cells and red blood cells, as well as an increase in the percentage of hemoglobin (HGB), hematocrit (HCT), the mean co
... Show MoreIn this paper, the density of state (DOS) at Fe metal contact to Titanium dioxide semiconductor (TiO2) has been studied and investigated using quantum consideration approaches. The study and calculations of (DOS) depended on the orientation and driving energies. was a function of TiO2 and Fe materials' refractive index and dielectric constant. Attention has focused on the effect of on the characteristic of (DOS), which increased with the increasing of refractive index and dielectric constant of Fe metal and vice versa. The results of (DOS) and its relation with and values of system have been discussed. As for contact system is increased, (DOS) values increased at first, but the relation is disturbed later and transforms into an inve
... Show MoreThis study explains the effect of non-thermal (cold) plasma on wound of diabetic rats by (FE-DBD) system, 3cm probe diameter is used. The output power was ranged from (12-20) W. The effect of non-thermal plasma on wounds of a diabetic was observed with different exposure durations (20,30) sec., the plasma exposure duration decreases the sugar level in blood and the diameter of the wound. These results indicate the cold plasma can be used to enhance the insulin level (i.e., blood sugar) and wounds treatment.
Phase change material (PCM) is considered as one of the most effective thermal energy storage (TES) systems to balance energy supply and demand. A key challenge in designing efficient PCM-based TES systems lies in the enhancement of heat transmission during phase transition. This study numerically examines the privilege of employing twisted-fin arrays inside a shell-and-tube latent heat storage unit to improve the solidification performance. The presence of twisted fins contributes to the dominating role of heat conduction by their curved shapes, which restricts the role of natural convection but largely aids the overall heat-transfer process during solidification. The heat-discharge
The research studied and analyzed the hybrid parallel-series systems of asymmetrical components by applying different experiments of simulations used to estimate the reliability function of those systems through the use of the maximum likelihood method as well as the Bayes standard method via both symmetrical and asymmetrical loss functions following Rayleigh distribution and Informative Prior distribution. The simulation experiments included different sizes of samples and default parameters which were then compared with one another depending on Square Error averages. Following that was the application of Bayes standard method by the Entropy Loss function that proved successful throughout the experimental side in finding the reliability fun
... Show MoreIn this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displacement amplitude respons
... Show More