The study of the laptop computer table is one of the important studies at the present time due to the importance of electronic computers that are used in work sites and homes for very long hours, so one of the most important basics of caring for the comfort of the user lies in the design of the laptop table in different shapes and sizes and multiple functions in addition to calculating the measurements of the human body and the extent Its compatibility with the design and measurements of laptop computer tables by taking into account the calculations and measurements of the dimensions of the user's body of all ages and their consistency and use with the general measurements of the tables and the importance of research comes through the establishment of a knowledge base covering the topic of research to be of benefit to designers and specialists in this field and of benefit to product users as this study is It included all aspects of the tables, and the aim of this study was: to find foundations for building the formal system for the laptop table to be more suitable for the user. As for the limits of the research, the study of the formal system for the laptop table of the Chinese company Havic and available in the Iraqi market during the year 2011-2012 This study contains four chapters, the first chapter includes the research problem and the need for it in addition to oh The amount of research and its objectives and limits. As for the second chapter, it included the previous studies and the theoretical framework, which in turn contained three topics, the first was titled Foundations of Building the Formal System for the Laptop Desk and it contained an overview of the laptop computer, the laptop table, the system, the shape, and the second topic was titled Multifunctionality of the Laptop Table The third topic is on the mechanism of the human body ergonomics and its relationship to the laptop table. And then this chapter ended with indicators. The third chapter includes research procedures and methodology, and includes description and analysis of sample samples according to the axes analysis form. Finally, the fourth chapter included the results of the analysis, conclusions, recommendations and proposals. 1. The design system was distinguished by the efficiency of the functional performance and it helped in that the flat and supportive surface of the table surface in addition to the mechanism of the movement of the legs up and down as well as laterally and this achieved a distinct performance aspect although there were no fans for cooling The laptop computer while working and this was achieved in Form No. (1) and the percentage was 50%, while Model No. (2) achieved higher efficiency in functionality due to the presence of fans and the percentage was 50% .2 The dimensions of the computer tables differed according to the user’s need, as they were voluntary To the user as he wants through the size of the table tops and its inclination mechanism in addition to controlling the height and drop of the table legs. 3 The interconnectedness between the design parts aims to influence the functionality in a good way and this was achieved through the use of appropriate fastening means for the mechanism of movement and movement of the table by 50%
Multiple eliminations (de-multiple) are one of seismic processing steps to remove their effects and delineate the correct primary refractors. Using normal move out to flatten primaries is the way to eliminate multiples through transforming these data to frequency-wavenumber domain. The flatten primaries are aligned with zero axis of the frequency-wavenumber domain and any other reflection types (multiples and random noise) are distributed elsewhere. Dip-filter is applied to pass the aligned data and reject others will separate primaries from multiple after transforming the data back from frequency-wavenumber domain to time-distance domain. For that, a suggested name for this technique as normal move out- frequency-wavenumber domain
... Show MoreBackground: Ostеoporosis is a systеmic disеasе of thе bonе that is charactеrizеd by rеducеd bonе mass, which lеads to incrеasеd bonе fragility and fracturеparticularly in postmеnopausal womеn.Thе aims of study was toеvaluatе thе rеlationship bеtwееn mandibular radiomorphomеtric indicеs obtainеd on digital panoramic radiographswith thе bonе minеral dеnsitiеs of thе lumbar spinееvaluatеd using dual-еnеrgy X-ray absorptiomеtry (DXA) scan, in a population of ostеoporotic and non-ostеoporotic fеmalеs. Matеrials and mеthods: In panoramic imagеs obtainеd from 60 fеmalе individuals dividеd еq
... Show MoreThe current study is designed to investigate the histological and immunohistochemical characteristics of the thyroid gland in adult male Sciurus anamalus. This study found that the thyroid gland of the Caucasian squirrel is located in the neck area, below the larynx, on both sides of the trachea. It has two lobes (right and left) with cylindrical shape. The histological studies revealed that the thyroid gland is surrounded by a capsule which consists of connective tissue and forming of two layers which are outer layer and inner layer, and a layer of adipose tissue appears overlapping the outer layer. The inner tissue of the gland consists of follicles with different shapes and sizes, and is lined with simple cuboidal epithelial tissue (foll
... Show MoreA multistep synthesis was established for the preparation of a new vanillic acid-1, 2, 4-1triazole-3-thiol conjugate (
A simple, rapid, sensitive and inexpensive approach is described in this work based on a combination of solid‐phase extraction of 8‐hydroxyquinoline (8HQ), for speciation and preconcentration of Cr(III) and Cr(VI) in river water, and the direct determination of these species using a flow injection system with chemiluminescence detection (FI–CL) and a 4‐diethylamino phenyl hydrazine (DEAPH)–hydrogen peroxide system. At different pH, the two forms of chromium [Cr(III) and Cr(VI)] have different exchange capacities for 8HQ, therefore two columns were constructed; the pH of column 1 was adjusted to pH 3 for retaining Cr(III) and column 2 was adjusted to pH 1 for retaining of Cr(VI). The sorbe
The largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreThe paper is devoted to solve nth order linear delay integro-differential equations of convolution type (DIDE's-CT) using collocation method with the aid of B-spline functions. A new algorithm with the aid of Matlab language is derived to treat numerically three types (retarded, neutral and mixed) of nth order linear DIDE's-CT using B-spline functions and Weddle rule for calculating the required integrals for these equations. Comparison between approximated and exact results has been given in test examples with suitable graphing for every example for solving three types of linear DIDE's-CT of different orders for conciliated the accuracy of the results of the proposed method.
This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show More