This research aims to identify the economic design techniques and materials that can be used in the implementation of cosmetic supplements to the spaces of the dwelling. The research relied on the descriptive and analytical approach by describing and analyzing models of design techniques and materials that can be used in the production of cosmetic supplements in the interior spaces of the dwelling.
The results of the research concluded that the beautification of the spaces of the dwelling is one of the necessary and important pieces to add aesthetic touches to the internal spaces, and that the use of economic design techniques and materials contributes to the implementation of many pieces of complementary beautification of the internal spaces of the dwelling at a simple cost and not exaggerated, and the research recommendations were the necessity Urging training centers to hold training courses and workshops for women in the field of home beautification and providing them with simple and economical techniques aimed at developing their awareness of home beautification, and stressing the need to train students in the courses related to home management or family education on how to use design techniques and materials and employ them in an economic way .
Phase change materials are known to be good in use in latent heat thermal energy storage (LHTES) systems, but one of their drawbacks is the slow melting and solidification processes. So that, in this work, enhancing heat transfer of phase change material is studied experimentally for in charging and discharging processes by the addition of high thermal conductive material such as copper in the form of brushes, which were added in both PCM and air sides. The additions of brushes have been carried out with different void fractions (97%, 94% and 90%) and the effect of four different air velocities was tested. The results indicate that the minimum brush void fraction gave the maximum heat transfer in PCM and reduced the time
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show MoreBackground: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t
... Show MoreBackground: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center
... Show MoreST Alawi, NA Mustafa, Al-Mustansiriyah Journal of Science, 2013
Background: Mini implant stability is primarily related to local bone density; no studies have evaluated bone density related to mini implant placement for orthodontic anchorage between different age groups in the maxilla and the mandible. The present research aims to evaluate side, gender, age, and regional differences in bone density of the alveolar bone at various orthodontic implant sites. Materials and method: Fifty three individuals who were divided into two groups according to their age into: group I (ages 16-20 years) and group II (ages 21-29 years) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 102 points (51 in the maxilla
... Show MoreThis research deals with the attitude of oil press towards oil industry in the world and the extent of their concerns with the stages of oil industry relating to the abundance of oil and natural gas, as it is an international strategic and complementary industry. The researcher uses the survey method for content analysis of the initial article and the press news for two: years (2011-2012). The results if the study are as follows
1- Oil press is concerned with developing and the stages of the Arabic oil industry in the interest of OAPEC in the first place.
2- It is concerned with exploring, extracting, and marketing oil in the first place, then with refining operations in refineries and petrochemical plants in the second place, an