Anticyclone of synoptic studies that influence weather and climate of Iraq, The aim of
the study is to clarify the effect variation of repetition of Anticyclone and effect on thermal
characteristic in Iraq were pressure level has been analyzed (1000) millibars and that because
of pressure level is the closet to the earth surface and the clarity of climatic phenomenon
based on a systematic analysis of synoptic seeking maps and observation and (12:00)
according to timing GMT for five climatic stations which is (Mosul, Kirkuk, Baghdad, Rutba,
and Basra) and so far three consecutive climatic cycles which is first climatic cycle for period
(1986-1976). and second climatic cycle for period (1997-1987) and third climatic cycle for
period (2008-1998).It become clear from the result. That study reach, It become clear that a clear depression
in repetition of Anticyclone from climatic session to another climatic session followed by
three climatic session and on all level of study area stations. The contrast repetition of
Anticyclone is one of the factors that help to raise the temperature due to air stillness and the
clarity of the sky that led to the concentration of pollutant and slow in their transition to other
areas. These pollutant increase rising temperatures air textures to the surface of earth because
it absorb ground radiation at night and reflect it to surface of earth as well as the clarity of the
sky during the day helped to increase the amount of solar radiation to the earth it is found
rising temperatures Siberian is the station (Mosul, Kirkuk, Rutba) for October month for
second climatic cycle for period (1997-1987) and third for period (2008-1998) as well as
increase temperatures maximum rate with increasing repetition rate of high semi-orbital in the
stations Mosul, Kirkuk, and Rutba area for each month of January and October in the second
climatic session for period (1997- 19987) as well as in the third climatic cycle for period
(2008-1998) in all stations of studying area for months of January and march and October and
the high rate of maximum temperature with high rate repetition of European Anticyclone in
all stations of studying area in the second climatic cycle for period(1997-1987) 0f January,
march, October months, Notice increase repetition rate of Siberian Anticyclone in the month
of October for two climatic cycle second and third as well as Basra station recorded increase
in minimum temperature rate with increase repetition rate of high semi-orbital in the second
climatic cycle for period (1997-1987) for January as well as in all stations of studying area in
the third climatic cycle for period (2008-1998) for march also in stations of Mosul, Kirkuk,
Basra for two climatic cycle the second and the third for October. And high rate of minimum
temperature with high repetition rate of European Anticyclone in the stations of Kirkuk and
Basra in January for the second climatic cycle period (1997-1987) as well as recorded in
march month in stations of Mosul and Kirkuk, Basra for two climatic cycle the second and
third also in October for the second climatic cycle for stations of studying area.
Tekrarlar, anlamı kuvvetlendirmek, ifadeyi zenginleştirmek amacıyla kullanılan dil unsurlarıdır. Ural Batır destanı da tekrarlar, özellikle de ikilemeler açısından zengindir. Bu yazıda, Ural Batır destanındaki ikilemeler gruplandırılarak verilecek ve değerlendirmesi yapılacaktır.
Abstract
Word repeating is language items used for strengthen the meaning and riching the expression. By this view, Ural Batır epic is a good example for word repeating units. In this paper, Ural Batır epic’s word repeating has been presented by classification.
Özet
Tekrarlar, anlamı kuvvetlendirmek, ifadeyi zenginleştirmek amacıyla kullanılan dil unsurlarıdır. Ural Batır destanı da tekrarlar, özellikle de ikilemeler açısından zengindir. Bu yazıda, Ural Batır destanındaki ikilemeler gruplandırılarak verilecek ve değerlendirmesi yapılacaktır.
Anahtar Kelimeler: Tekrar, ikileme, aralıklı ikileme, destan.
Abstract
Word repeating is language items used for strengthen the meaning and riching the expression. By this view, Ural Batır epic is a good example for word repeating units. In this paper, Ural Batır epic’s word repeating has been presented by classification.
Key Words: Repeating, a pair words, a pair words by space, epic.
The investigation of the effect of tempering on thermal analysis of
Al-Ti-Si alloy and its composites with MgO and SiC particles was
performed. Thermal analysis was performed before and after
tempering by DSC scan. Optical microscopy was used to identify the
phases and precipitations that may be formed in base alloy and
composites. X-ray diffraction test indicated that the Al3Ti is the main
phase in Al-Ti-Si alloy in addition to form Al5Ti7Si12 phase. Some
chemical reactions can be occurred between reinforcements and
matrix such as MgO.Al2O3 in Al-Ti/MgO, and Al4C3 and Al(OH)3 in
Al-Ti/SiC composite. X-ray florescence technique is used to
investigate the chemical composition of the fabricated specimens.
H
In this paper the effect of thermal annealing on the structural and optical properties of Antimony Selenide (Sb2Se3) is investigated. Sb2Se3 powder is evaporated on clean amorphous glass substrates at room temperature under high vacuum pressure (4.5×10-6 mbar) to form thin films. The structural investigation was done with the aid of X-ray diffraction (XRD) and atomic force microscopy (AFM). The amorphous to polycrystalline transformation of these thin films was shown by X-ray diffraction analysis after thermal annealing. These films' morphology is explained. (UV-Vis ) spectra in ranges from 300 to 1100 nm was used to examine the optical properties of the films .The absorption coefficient and optical energy gap of the investigated films are
... Show More An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct
Abstract
This paper concerned with study the effect of a graphite micro powder mixed in the kerosene dielectric fluid during powder mixing electric discharge machining (PMEDM) of high carbon high chromium AISI D2 steel. The type of electrode (copper and graphite), the pulse current and the pulse-on time and mixing powder in kerosene dielectric fluid are taken as the process main input parameters. The material removal rate MRR, the tool wear ratio TWR and the work piece surface roughness (SR) are taken as output parameters to measure the process performance. The experiments are planned using response surface methodology (RSM) design procedure. Empirical models are developed for MRR, TWR and SR, using the analysis
... Show MoreIn spite of the disappearing of a clear uniform textbook for teaching ESP at different departments and different colleges in both scientific and humanistic studies, the practitioners at those departments and colleges have to teach translation as one of the important requirements to pass the English language exam. The lack of defined translation activities is a noticeable problem therefore; the problem of teaching translation is diagnosed in that the students lack the ability to comprehend the text in English language and other translation knowledge and skills.
The study aims to suggest a translation strategy and then find out the effect of the translation strategy on ESP learners’ achievement in translation. A sample of 50 stud
... Show MoreThe reclamation of makeup water is studied in terms of breakthrough time (i.e., the leakage of the cations). Makeup water was subjected to lab-scale ion exchangers of two types: strong acid cation and weak base anion exchanger. The experimental investigation was directed to study the ion exchanger performance in terms of four different parameters (i.e., copper concentration, total dissolved solids (TDS), feed rate and bed depth). Box-Wilson composite rotatable design was adopted in designing the experiments. Breakthrough times of the effluent stream are measured in terms of copper concentration of 2 to 25 ppm, TDS concentration of 250 to 1250 ppm, feed rate of 0.38 to 5.34 l/h and bed depth of 5 to 70 cm. Simulation the effect of the stu
... Show More