Preferred Language
Articles
/
jbcd-969
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of immersion period using analytic balance device. Results: The release different metal ions was observed: nickel (Ni), chromium (Cr) and iron (Fe)). Statistically analysis of variance (ANOVA) and t-test were used. Results showed that (1) the appliances released measurable quantities ofall ions examined; (2) the change in pH had a very strong effect on the release of ions; (3) the release of ions was dependent on wire composition, but it was not proportionalto the content of metal in the wire and (4) orthodontic samples showed decreases in the weight at the end of the study. Conclusion: Levels of released ions are sufficient to cause delayed allergic reactions. This must be taken into account when type of archwire is selected, especially in patients with hypersensitivityor compromised oral hygiene.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
...Show More Authors

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .

In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.                     

The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Australian Dental Journal
Debonding of LDSVs utilising Er,Cr:YSGG laser irradiation with fractional technique: an in vitro study
...Show More Authors

Scopus (5)
Scopus
Publication Date
Fri Jul 24 2026
Journal Name
Modern Sport
Time out in basketball and it effect on playing for excellent degrees in Iraq
...Show More Authors

The value of time out as a time not count of official time form the game like four periods and extra time also it considered a great interest if used well thru the game , the importance of this problem is not using well the time out and when the coach ask for time out and how to invest this time legally to make good results also there is no observing system as the researcher see gives the reality image that the coach is successful lead the game when he takes time out . The goals of research that knowing on numbers of time out for excellent teams in Iraq (first &second) stages and putting special inventory reverse reality of asking time out (positive &negative) on playing basketball , the hypothesis of research that tell the time out effect

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Artificial Aging Test on PEEK CAD/CAM Fabricated Orthodontic Fixed Lingual Retainer
...Show More Authors

Background: The purpose of this study was to evaluate the effect of in vitro long-term simulation of oral conditions on the bond strength of PEEK CAD/CAM lingual retainers.

Material and methods: The sample consisted of 12 PEEK CAD/CAM retainers each composed of 2 centrally perforated 3x4mm pads joined by a connector. They were treated by 98% sulfuric acid for 1 minute and then conditioned with Single Bond Universal and bonded to the lingual surface of premolar teeth by 3M Transbond TM System. Half of the retainers were artificially aged using a 30-day water storage and 5000 thermocycling protocol before bond strength testing to compare with the non-aged specimens.

Results: The artificially aged retainers showed a marginally

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (10)
Scopus Crossref
Publication Date
Thu Aug 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Factors that Effect on the Level of Accounting Conservatism A sample study Of insurance companies which listed on the Amman Stock Exchange (2005-2016)
...Show More Authors

This study aimed to measure  the accounting conservatism  and the lemited factors which  affected on it in the annual financial reports of insurance companies which listed on the Amman Stock Exchange during the period from 2005 to 2016, these factors were represented by firm age, firm debt and firm size.

Using the market value model (MV) To book value  ( BV) Beaver and Ryan (2000) The level of the accounting conservatism was measured. The study found that the insurance companies which are listed on the ASE exercise the accounting conservatism when they were  preparing financial reports. And when conducting a process  of the test of the affected of the factors (The age of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 31 2025
Journal Name
Indonesian Journal Of Chemistry
Evaluation of the Antioxidant and Anticancer Effectiveness of Some New Metal Ions Complexes with Azo Dye: Synthesis and Characterization
...Show More Authors

This paper presents a new azo dye 3-[2-(1H-indol-2-yl)ethyldiazenyl]quinolin-2-ol] from the reaction of the diazonium salt derived from tryptamine and 2-hydroxyquinoline. Azo dye was used to prepare a series of complexes with the chlorides of Ni(II), Pt(IV), Pd(II), Cd(II), and Zn(II). Compounds were analyzed and characterized using elemental analysis, magnetic measurement, UV-vis, IR, MS, NMR, and conductivity. The findings demonstrated that the ligand acts as ionic in complex form, O-bidentate, supporting the proposed formula. The complexes generally exhibited tetrahedral and octahedral geometries, except the palladium complex, which adopted a square planar geometry. TGA was used to investigate the thermal characteristics of compo

... Show More
View Publication
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Study the effect of a new nikel (II) Complex and anticancer drug (cp) on Liver enzyme activity (GPT,GOT) and Creatinine level in Kidney of femal mice
...Show More Authors

This study involved the effect of anew nickel (II) complexs with formla [NiL2(H2O)2].2.5ETOH where L=Bis[5-(p-nitrophenyL)-4-phenyL-1,2,4-traizole-3-dithocarbamato hydrazide] diaqua. nickel(II). Ethanol(2.5).and anti-cancer drug cyclophosphamide on specific actifity of two Liver enzymes (GOT,GPT) in the (Liver,kidney) tissues and on the creatinine Level in the kidney byUtilizing an invivosystem in femalmice.The result showed that inhibition in the activity of GPT and GOT enzymes in theLiver and in both nickel (II) complex and cyclophosphamide drug (CP) . mice weretreated with three doses (90,180,320) µg/mouse for three days for each group.The Liver show's the highest rate of GPT inhibition was about 97.43% at180µg/mouse regarding the ki

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Water flow velocity and oxide film formation effect on copper pipe corrosion
...Show More Authors

An overall mathematical model for copper pipe corrosion in flowing water was derived based on mass transfer fundamentals where we introduced the effects of boundary layer velocity, bulk flow velocity and the surface oxide protective film on the corrosion rate. A set of experiments were conducted in a straight 10mm diameter copper pipe, flow of water include six velocities of maximum value 7.33m/sec at 200C and 350C. The good agreement between the calculated and experimental corrosion rate values were achieved , the agreement reached 92% .

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Coated stainless steel archwires' discoloration measured by computerized system (An in-vitro study)
...Show More Authors

Background: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Resu

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Human Skin WoundWelding Using 980 nm Diode Laser: an in Vitro Experimental Study
...Show More Authors

Laser assisted skin wound closure offers many distinct advantages over conventional closure
techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for
Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in
welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human
skin obtained from the discarded panniculus of an Abdominoplasty operation were tried to be laser
welded using a 4 mm spot diameter laser beam from a 980 nm diode laser at different laser parameters
and modes of action. The tensile strength at the weld site was analyzed experimentally. Although laser
assisted wound welding did

... Show More
View Publication Preview PDF