Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 implants in (D4)). Resonance frequency analysis was used for direct measurement of implant stability on the day of implant placement and 8, 16 and 24 weeks after implant placement. Results: The lowest mean of average ISQ was at the 8th week (69.5) and then the mean increased to reach at the 24th week (76.8). Mandibular implants showed significantly higher ISQ values than maxillary implants. Implants placed in the posterior segment of the jaw had significantly higher ISQ values than implants in the anterior segment. A significant, positive linear correlation was observed between the implant diameter and the implant stability (r=0.343 p<0.001). Conclusion: Resonance frequency analysis was non-invasive diagnostic tool for detecting changes in implant stability during the healing period. The factors that affect implant stability were implant diameter and implant location (maxilla\ mandible, anterior\ posterior).
Severe periodontitis is ranked as the sixth most prevalent disease affecting humankind, with an estimated 740 million people affected worldwide. The diagnosis of periodontal diseases mainly relies upon assessment of conventional clinical parameters. However, these parameters reflect past, rather than current, clinical status or future disease progression and, likely, outcome of periodontal treatment. Specific and sensitive biomarkers for periodontal diseases have been examined widely to address these issues and some biomarkers have been translated as point-of-care (PoC) tests. The aim of this review was to provide an update on PoC tests for use in the diagnosis and management of periodontal diseases. Among the PoC tests developed so
... Show MoreBanking reforms in many countries have focused on the efficiency enhance of the banking sector, including Iraq, in terms of indicative steps based on recommendations, policies and standards developed by international organizations, foremost of which are Basel III. In this paper, it has tried to highlight the reforms in Basel III and the impact of these reforms on the stability of the banking system in Iraq. As the research derives its importance from the idea that the sound banking system consists of a group of banks capable of employing their assets and obligations efficiently in financial intermediation and enjoying financial solvency. The stability of the banking system is an important factor in achieving the leading role of t
... Show MoreFinancial inclusion refers to the access of financial services at low cost and high-quality from the formal financial sector to all segments of society, especially marginalized groups, and then use and benefit from them. Financial inclusion is also associated with banking stability, as well as with financial integrity and financial protection for the consumer, therefore, it achieves a number of objectives, the most important of which is to support and enhance banking stability. This is what made it attract the attention of many countries and central banks recently.
The study aims to show the impact of financial inclusion indicators on ban
... Show MoreWellbore instability problems cause nonproductive time, especially during drilling operations in the shale formations. These problems include stuck pipe, caving, lost circulation, and the tight hole, requiring more time to treat and therefore additional costs. The extensive hole collapse problem is considered one of the main challenges experienced when drilling in the Zubair shale formation. In turn, it is caused by nonproductive time and increasing well drilling expenditure. In this study, geomechanical modeling was used to determine a suitable mud weight window to overpass these problems and improve drilling performance for well development. Three failure criteria, including Mohr–Coulomb, modifie
DBNRHM Sami, International Journal of Research in Social Sciences and Humanities, 2020
A pioneering idea for increasing the thermal performance of heat transfer fluids was to use ultrafine solid particles suspended in the base fluid. Nanofluids, synthesized by mixing solid nanometer sized particles at low concentrations with the base fluid, were used as a new heat transfer fluid and developed a remarkable effect on the thermophysical properties and heat transfer coefficient. For any nanofluid to be usable in heat transfer applications, the main concern is its long-term stability. The aim of this research is to investigate the effect of using four different surfactants (sodium dodecyl benzene sulfonate (SDBS), sodium dodecyl sulfate (SDS), cetyl trimethylammonium bromide (CTAB), and gum Arabic (GA)), each with three different
... Show MoreBiped robots have gained much attention for decades. A variety of researches have been conducted to make them able to assist or even substitute for humans in performing special tasks. In addition, studying biped robots is important in order to understand human locomotion and to develop and improve control strategies for prosthetic and orthotic limbs. This paper discusses the main challenges encountered in the design of biped robots, such as modeling, stability and their walking patterns. The subject is difficult to deal with because the biped mechanism intervenes with mechanics, control, electronics and artificial intelligence. In this paper, we collect and introduce a systematic discussion of modelin
Different polymers were prepared by condensation polymerization of sebacic anhydride and adipic anhydride with ethylene glycol and poly(ethylene glycol). Their number average molecular weights were determined by end group analysis. Then, they were grafted on the prepared phthalocyaninatocopper(II) compounds with the general formula (NH2)4PcCu(II) having amino groups of 3,3',3'',3'''- or 4,4',4'',4'''- positions. All prepared polymers, compounds, and phthalocyaninatocopper(II)-grafted polymers were characterized by FTIR. The sizing measurements were carried out in 3,3',3'',3'''- (NH2)4PcCu(II) and 4,4',4'',4'''- (NH2)4PcCu(II) compounds with and without grafting polymers. The results showed that the grafting process led to decreasing in par
... Show MoreBackground: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show More