Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fat, water, and muscle; bone mass; and basal and active metabolic rates. Results: No significant difference in overall bone density and thickness of hard palate during 3rd and 4th decades. The gender should be considered in regard to bone thickness. Cortical bone density and thickness showed a tendency to decrease posteriorly, while the cancellous bone density showed a tendency to increase posteriorly. In the mediolateral areas, no specific patterns were observed. With increasing BMI, the cortical bone density was increased. The relationships of bone density and thickness with most scale measurements were not significant. Conclusion: Mini-implants for orthodontic anchorage can be effectively placed in most areas of hard palate regarding the bone density. While regarding bone thickness, care should be taken during the planning of their placement in hard palate. A new classification for bone thickness of hard palate has been developed.
Steps were taken to obtain the Kojic acid crystals from local fungal isolation A. flavus WJF81 by separating the fermentation products from the fungus mycelium from the production plant at the centrifuge at a speed of 5000 cycles for 10 minutes. The extraction was followed by ethyl acetate then supernatant concentrate by using rotary evaporator, and dried with heat oven 37ºC. Long, yellowish, pristine acid crystals were obtained that examined the optical microscope with a magnification force of 10x and 40x. The melting point of kojic acid was determined between 152.9-153.5 °C Results of the diagnosis of Kojic acid by applying High pressure liquid chromatography HPLC technique showed that the acid was at one peak, which was close to the
... Show MoreMJ Abbas, AK Hussein, Journal of Physical Education, 2019
Inflammation of the tonsils could be described as acute tonsillitis, mainly due to infection. Recurrent tonsillitis could be defined as 3-7 episodes during the first 3 years of age. Vitamin D, which is a neuro-hormone with pleiotropic biological activities may modulate the immune response by alleviation, and stimulation of Th1 and Th2 cell proliferation, respectively, that influence the stimulation, synthesis, and secretion of both pro and anti-inflammatory cytokines. In this study we aimed to shed light on the levels of vitamin D in children with different episodes of tonsillitis in association with levels of interleukins (TNFα, IL-2, IL-4, IL-10). Blood samples were collected from 48 participants in 3 groups: control, acute tonsilliti
... Show MoreIn this research, the results of the Integral breadth method were used to analyze the X-ray lines to determine the crystallite size and lattice strain of the zirconium oxide nanoparticles and the value of the crystal size was equal to (8.2nm) and the lattice strain (0.001955), and then the results were compared with three other methods, which are the Scherer and Scherer dynamical diffraction theory and two formulas of the Scherer and Wilson method.the results were as followsScherer crystallite size(7.4nm)and lattice strain(0.011968),Schererdynamic method crystallite size(7.5 nm),Scherrer and Wilson methodcrystallite size( 8.5nm) and lattice strain( 0.001919).And using another formula for Schearer and Wilson methodwe obtain the size of the c
... Show MoreBreast cancer is the commonest cancer affecting women worldwide. Different studies have dealt with the etiological factors of that cancer aiming to find a way for early diagnosis and satisfactory therapy. The present study clarified the relationship between genetic polymorphisms of BRCA1 & BRCA2 genes and some etiological risk factors among breast cancer patients in Iraq. This investigation was carried out on 25 patients (all were females) who were diagnosed as breast cancer patients attended AL-Kadhemya Teaching Hospital in Baghdad and 10 apparently healthy women were used as a control, all women (patients and control) aged above 40 years. The Wizard Promega kit was used for DNA isolation from breast patients and normal individuals. B
... Show MoreThe current research aims to :
•know the level of social intelligence of the sample as a whole .
. •taraf statistically significant differences in social intelligence between disadvantaged and
non-disadvantaged peers .
To achieve these objectives, the selected sample of Talbhalmrahlh medium and specifically
students of the second grade average, were chosen randomly stratified's (360) students
included sex (male, female) and (deprived of the Father and the non-deprived) for the
academic year (2013-2014) for the province of Baghdad on both sides (Rusafa-Karkh (
As applied to them measurements of social intelligence, which is prepared by the researcher,
having achieved _khasaúsma of psychometric (valid and re
Background: Osteoporosis is a systemic skeletal disorder affects general health in addition to effect on salivary physical and chemical composition which lead to an adverse effect on oral health status. This study was conducted to evaluate the concentration of glycoprotein (osteonectin) in saliva and its effect on dental caries in relation to salivary flow rate and viscosity among osteoporotic women and compared to control group. Materials and Methods: The total sample composed of 60 females aged 60-65 years attending Al-Yarmook Teaching Hospital, 30 females diagnosed with osteoporosis by measuring bone density at the spine and femur with a dual-energy X-ray absorptiometry at T-score of >2.5, and 30 women without osteoporosis with T-score o
... Show MoreIn this study, four different spectrophotometric methods were applied for determination of cimetidine and erythromycin ethylsuccinate drugs in pure form and in their pharmaceutical preparations. The suggested methods are simple, sensitive, accurate, not time consuming and inexpensive. The results showed the following: The first method: Based on the formation of ion pair complex of each drug with bromothymol blue (BTB) as a chromogenic reagent. The formed complexes were extracted with chloroform and their absorbance values were measured at 427.5 nm for cimetidine and 416.5nm for erythromycin ethylsuccinate; against their reagents blanks. Two different methods, univariate method and multivariate method, were used to obtain the optimum condit
... Show MoreA rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea
... Show MoreThis approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo
... Show More