Preferred Language
Articles
/
jbcd-730
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fat, water, and muscle; bone mass; and basal and active metabolic rates. Results: No significant difference in overall bone density and thickness of hard palate during 3rd and 4th decades. The gender should be considered in regard to bone thickness. Cortical bone density and thickness showed a tendency to decrease posteriorly, while the cancellous bone density showed a tendency to increase posteriorly. In the mediolateral areas, no specific patterns were observed. With increasing BMI, the cortical bone density was increased. The relationships of bone density and thickness with most scale measurements were not significant. Conclusion: Mini-implants for orthodontic anchorage can be effectively placed in most areas of hard palate regarding the bone density. While regarding bone thickness, care should be taken during the planning of their placement in hard palate. A new classification for bone thickness of hard palate has been developed.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 29 2022
Journal Name
Arterial Hypertension
Correlation between coronary artery calcium score and aorta diameter in population with long-standing hypertension using noncontrast CT scan
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Sex Variations by Linear Measurements of Palatal Bones and Skull Base Using 3D Reconstructed Computed Tomographic Scan among Iraqi Sample
...Show More Authors

Background: The skull base and the hard palate contain many anatomical features that make them rich in information which are useful in sex differentiation; in addition to that they have the ability to resist the hardest environmental conditions that support them in making sex differentiation. Three dimensional computed tomographic techniques has important role in differentiation between sex since it offers images with very accurate data and details of all anatomical structures with high resolution. This study was made to study sex variations among Iraqi sample by craniometric linear measurements of the hard palate and the skull base using 3D reconstructed Computed Tomographic scan. Materials and methods: This study composed of 100 Iraqi su

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Crestal Bone Resorption around Dental Implants in Flapped and Flapless Surgical Techniques Depending on Cone Beam CT Scan (Comparative Study)
...Show More Authors

Background: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Nov 04 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
MEASURING OBESITYLEVEL BY BIO-ELECTRICAL IMPEDANCE ANALYSIS TECHNIQUE AND COMPARED TO TRADITIONAL METHODS: MEASURING OBESITYLEVEL BY BIO-ELECTRICAL IMPEDANCE ANALYSIS TECHNIQUE AND COMPARED TO TRADITIONAL METHODS
...Show More Authors

This study aimed to determine obesity level of some population in Baghdad by using Bio-electrical impedance analysis (BIA) and compared with anthropometric measurements such as body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR). Statistical analysis results of linear correlation coefficients for obesity indicators showed that BIA correlation 0.92 was most significant and reliable for obesity measurement.

Results of BIA method for age group 20-29 years showed that 44.4% of females were healthy body while 37.8% of males suffer from increased body fat. Results of age group 30-39 year showed that 32.6 of females were in healthy body and 42% of males were obese. In case age group 40-4

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Buccal Cortical Bone Thickness in Iraqi Arab Adults by Cone Beam Computed Tomography for Orthodontic Mini-Implants
...Show More Authors

ABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Iraqi Journal Of Physics
Enhancement CT Scan Image and Study Electronic, Structural and Vibrational Properties of Iobenguane
...Show More Authors

This work is divided into two parts first part study electronic structure and vibration properties of the Iobenguane material that is used in CT scan imaging. Iobenguane, or MIBG, is an aralkylguanidine analog of the adrenergic neurotransmitter norepinephrine and a radiopharmaceutical. It acts as a blocking agent for adrenergic neurons. When radiolabeled, it can be used in nuclear medicinal diagnostic techniques as well as in neuroendocrine antineoplastic treatments. The aim of this work is to provide general information about Iobenguane that can be used to obtain results to diagnose the diseases. The second part study image processing techniques, the CT scan image is transformed to frequency domain using the LWT. Two methods of contrast

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Emergency Medicine, Trauma And Acute Care
Cone beam computed tomography (CBCT) evaluation of ridge shape and bone density in Iraqi sample pre-dental implant insertion
...Show More Authors

One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jun 02 2023
Journal Name
East European Journal Of Physics
Reevaluation Body Weight and Age with Standardized Uptake Value in the Liver Cancer for [18F] FDG PET/CT
...Show More Authors

Standardized uptake values, often known as SUVs, are frequently utilized in the process of measuring 18F-fluorodeoxyglucose (FDG) uptake in malignancies . In this work, we investigated the relationships between a wide range of parameters and the standardized uptake values (SUV) found in the liver.  Examinations with 18F-FDG PET/CT were performed on a total of 59 patients who were suffering from liver cancer. We determined the SUV in the liver of patients who had a normal BMI (between 18.5 and 24.9) and a high BMI (above 30) obese. After adjusting each SUV based on the results of the body mass index (BMI) and body surface area (BSA) calculations, which were determined for each patient based on their height and weight. Under a variety of dif

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Apr 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the relationship between maxillary sinus floor and maxillary posterior teeth root apices using spiral CT scan
...Show More Authors

Background: The purpose of this study is to investigate the relationship between the roots of the maxillary posterior teeth and the maxillary sinus using spiral computed tomography, and measured the distances between the roots of the maxillary posterior teeth and the sinus floor. Materials and Methods: The sample of the present study was a total of 120 Iraqi subject (60 males & 60 females) aged (20-60) years old, who admitted to spiral Computed Tomography scan unit in AL-Zahraa hospital in AL-Kut city to have Computed Tomography scan of the brain and paranasal sinuses who had complaints of headaches or with suspicion of sinusitis but without pathological findings in maxillary sinuses. From November 2012 to April 2013, CT sagittal reconstruc

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Indian Journal Of Natural Sciences
Determination of the Electron Density Variation for Ionosphere Layer Over Iraqi Zone Using IRI Model
...Show More Authors

KA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1

View Publication