Preferred Language
Articles
/
jbcd-2713
Evaluation of Crestal Bone Resorption around Dental Implants in Flapped and Flapless Surgical Techniques Depending on Cone Beam CT Scan (Comparative Study)
...Show More Authors

Background: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and flapless approach depending on CBCT during 24 weeks healing period. Materials and Methods: A total of 25 Iraqi patients with an age ranged of 20-60 years who received 46 implants. Were randomized into two groups: control group which involved 27 implants inserted by conventional flapped surgical approach and study group which involved 19 implants inserted by flapless surgical approach. The bone level was measured by CBCT for each implant at buccal and palata/lingual sides at two times, immediately after implant placement (base line data), and after 24 weeks healing period. Results: There was no significant difference between study (flapless) and control (flapped) groups in the mean of total crestal bone resorption for buccal and palatal side after 24 weeks from implant placement (P= 0.393 for buccal side and P= 0.214 for palatal side). There was highly significant difference between buccal and palatal side regarding crestal bone loss around implants (P = 0.001) Conclusions: Bone resoption around dental implants placed with conventional flap surgery compared to flapless surgery does not seem to be influenced during the healing period before implant loading.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis
...Show More Authors

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (10)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Reliability of Two Different Laser Wavelengths in Inducing Bone Healing Around Dental Implants: Comparative Clinical Trial
...Show More Authors

Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Osseointegration & Oral Rehablitation
Evaluation of marginal bone loss around SLActive implants by CBCT using different implant dimensions and surgical approaches: A clinical and radiological prospective study
...Show More Authors

Aim: The reduction in the amount of marginal bone is the most important demand for the long term success of dental implants. This prospective clinical study was aimed to investigate the marginal bone loss of early loaded SLActive implants with different dimensions and surgical approaches. Materials and methods Fifteen patients aged from 18 to 60 years were divided into 2 groups (flapped and flapless approach) that underwent delayed implant placement protocol with SLActive implants. The marginal bone level was estimated by cone-beam computed tomography during three different periods: preoperatively, 8 weeks after surgery and 24 weeks after loading of the prosthesis. Results: The mean value of marginal bone level was not significantly chan

... Show More
View Publication Preview PDF
Scopus (4)
Scopus
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Emergency Medicine, Trauma And Acute Care
Cone beam computed tomography (CBCT) evaluation of ridge shape and bone density in Iraqi sample pre-dental implant insertion
...Show More Authors

One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Buccal Cortical Bone Thickness in Iraqi Arab Adults by Cone Beam Computed Tomography for Orthodontic Mini-Implants
...Show More Authors

ABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Dec 25 2017
Journal Name
Biomedical And Pharmacology Journal
Evaluation of Crestal Bone Loss and Alkaline Phosphatase Level in Saliva According To Different Flap Designs in Single-Tooth Dental Implant Surgery (A Clinical Comparative Study)
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Clinical Dentistry Preview Publication Details
The effect of surgical approaches on the stability and marginal bone loss of early loaded slactive implants with screw retention mean: Comparative clinical and radiological prospective study
...Show More Authors

Purpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app

... Show More
View Publication Preview PDF
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Russian Electronic Journal Of Radiology
COHORT COMPARATIVE STUDY OF COVID-19 VACCINATED AND NON-VACCINATED PATIENTS DEPENDING ON CT CHEST FINDINGS BETWEEN IRAQI AND JORDANIAN POPULATION
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Crossref