Background: Biologically active substances, such as Cathepsin B (CAB) which is a lysosomalcystein protease may be involved in periodontal metabolism in the degradation of organic bone matrix containing collagen fibers in response to mechanical stress from orthodontic appliance. The aims of study were to determine and compare salivary levels of CAB, pH as well as clinical periodontal parameters (Plaque index PLI and gingival index GI) with different orthodontic force magnitudes at different time intervals. Materials and methods: A twenty-four patients (both gender) with age range (17-23) years had Angle's Class II division 1 malocclusion with GI >0.5 enrolled in this study. The level of salivary CAB and pH, in addition to the clinical periodontal parameters (PLI and GI) were measured before (baseline), 1 hour (1H), 1 day (1D), 1week (1W), 2 weeks (2W) and 3 weeks (3W) after fixed orthodontic appliance placement with different forces applied to the teeth (F1 (40 gm), F2 (60 gm) and F3 (80 gm)). Results: The highest mean concentration of salivary CAB was (12.057) at F1 in 1D visit with highly significant differences among the visits as well as among the forces (p≤0.05). Weak correlations were revealed between all pairs of forces as well as between each visit with the baseline visit about salivary CAB except the strong negative correlations between F1 with F3 at 3W and baseline with 3W visits at F3. Maintenance of good oral hygiene during the study period demonstrated that the highest mean values of PLI and GI were (0.2) and (0.25) respectively, in addition to the non-significant differences regarding pH among the visits. Conclusion: The concentration of salivary CAB was increased following fixed orthodontic appliance insertion. The very light continuous orthodontic force could produce significant increase of this enzyme activity and give enough effectiveness to produce tooth movement as compared to the higher forces.
In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur
... Show MoreExperimental investigation for small horizontal portable wind turbine (SHPWT) of NACA-44, BP-44, and NACA-63, BP-63 profiles under laboratory conditions at different wind velocity range of (3.7-5.8 m/s) achieved in present work. Experimental data tabulated for 2, 3, 4, and 6- bladed rotor of both profiles within range of blade pitch angles . A mathematical model formulated and computer Code for MATLAB software developed. The least-squares regression is used to fit experimental data. As the majority of previous works have been presented for large scale wind turbines, the aims were to present the performance of (SHPWT) and also to make a comparisons between both profiles to conclude which is the best performance. The overall efficiency and el
... Show MoreIn this research, the problem of multi- objective modal transport was formulated with mixed constraints to find the optimal solution. The foggy approach of the Multi-objective Transfer Model (MOTP) was applied. There are three objectives to reduce costs to the minimum cost of transportation, administrative cost and cost of the goods. The linear membership function, the Exponential membership function, and the Hyperbolic membership function. Where the proposed model was used in the General Company for the manufacture of grain to reduce the cost of transport to the minimum and to find the best plan to transfer the product according to the restrictions imposed on the model.
In this research, damping properties for composite materials were evaluated using logarithmic decrement method to study the effect of reinforcements on the damping ratio of the epoxy matrix. Three stages of composites were prepared in this research. The first stage included preparing binary blends of epoxy (EP) and different weight percentages of polysulfide rubber (PSR) (0%, 2.5%, 5%, 7.5% and 10%). It was found that the weight percentage 5% of polysulfide was the best percentage, which gives the best mechanical properties for the blend matrix. The advantage of this blend matrix is that; it mediates between the brittle properties of epoxy and the flexible properties of a blend matrix with the highest percentage of PSR. The second stage
... Show MoreThe steady state performance of the counter rotating floating ring Journal bearing is analyzed with isothermal finite bearing theory. The effect of different parameters affecting the performance of the bearing (namely speed ratio, clearance ratio and radii ratio), have been investigated. The load carrying capacity of the bearing increasing with decreasing the radii ratio (R2/R1) of the ring and clearance ratio (c1/c2), in the other hand, the coefficient of friction increases with increasing the clearance and radii ratios, while decreases with incre4asing the bearing to journal speed ratio (γ). It is shown during this work that different operating conditions are greatly enhanced the performance
... Show MoreObjective(s): This study aims to evaluate the hardness of two commercially available cold cured acrylic resin material
(Vertex and PAN) when polymerized at different temperature in comparison to those polymerized by conventional
methods in air at 23C ± 5C.
Methodology: Eighty specimens, forty from cold cured acrylic (Vertex Type) and forty from cold cured acrylic (PAN
type) were prepared, flasking and packing procedure were done according to manufacturer direction and divided
according to processing as follow: 20 specimens (10 from Vertex type and 10 from PAN type) were processed in air for
two hours at 23C ± 5C under press (bench curing) as a control, and 60 specimens (30 from Vertex type and 30 from
PAN type) wer
This research presents an experimental investigation on the influence of metakaolin replacement percentage upon some properties of different concrete types. Three types of concrete were adopted (self- compacted concrete, high performance concrete and reactive powder concrete) all of high sulphate (SO3) percentage from the fine aggregate weight, 0.75%. Three percentages of metakaolin replacement were selected to be studied (5, 7 and 10) %. Three types of concrete properties (compressive, flexural and splitting tensile strength) were adopted to achieve better understanding for the influence of adding metakaolin.. The output results indicated that the percentage of metakaolin had a different level of positive effect on the compressive strength
... Show MoreIn this paper, we present a comparison of double informative priors which are assumed for the parameter of inverted exponential distribution.To estimate the parameter of inverted exponential distribution by using Bayes estimation ,will be used two different kind of information in the Bayes estimation; two different priors have been selected for the parameter of inverted exponential distribution. Also assumed Chi-squared - Gamma distribution, Chi-squared - Erlang distribution, and- Gamma- Erlang distribution as double priors. The results are the derivations of these estimators under the squared error loss function with three different double priors.
Additionally Maximum likelihood estimation method
... Show MoreThis study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show More