Preferred Language
Articles
/
jbcd-708
Estimation of the linear dimensional changes of autoclave cured acrylic resin with multiple palatal depths and investment materials
...Show More Authors

Background: Dimensional changes of acrylic denture bases after polymerization results in need for further adjustments or even ends with technical failure of the finished dentures. The purpose of this study was to estimate the linear dimensional changes for different palatal depths when using multiple investment materials and polymerization techniques. Materials and methods: Ninety upper complete denture bases were constructed for this study. They were divided into two main groups according to the polymerization methods: conventional water bath and experimental autoclave (short and long cycles). Each main group was further subdivided into three subgroups according to the palatal depth (shallow, medium and deep). Furthermore, for each palatal depth; complete denture bases were invested either with dental stone or laboratory silicone. For each upper complete denture, measurements of linear dimensional changes were done by fixation of metallic screws on the tissue surface of the denture base. The distances were measured by using travelling microscope with an accuracy of 0.001 %. The data were statistically analyzed using three way analysis of variance (ANOVA) for three variables, which were (palatal depth, investments and polymerization techniques), LSD test and student T test for comparisons between groups. Results: There were significant improvements in the dimensional accuracy of denture bases cured with autoclave compared with water bath. Also, silicone investments were a successful alternative to stone, study data shows that short autoclave processing with silicone reduces the magnitude of the linear dimensional changes. On the other hand, long autoclave processing and stone investments were better than silicone in reducing dimensional changes. Conclusion: The findings of this study indicates that the use of autoclave processing in acrylic curing is a promising alternative to the conventional water bath and leads to better dimensional stability for the finished dentures in all oral configurations and palatal depths. Also, Silicone is more preferable than stone, although it's not as strong investing materials when compared with stone.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 01 2019
Journal Name
مجلة العلوم الاقتصادية والإدارية
Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
...Show More Authors

Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application

Publication Date
Mon Jul 01 2024
Journal Name
Alexandria Engineering Journal
Comparison of some Bayesian estimation methods for type-I generalized extreme value distribution with simulation
...Show More Authors

The Weibull distribution is considered one of the Type-I Generalized Extreme Value (GEV) distribution, and it plays a crucial role in modeling extreme events in various fields, such as hydrology, finance, and environmental sciences. Bayesian methods play a strong, decisive role in estimating the parameters of the GEV distribution due to their ability to incorporate prior knowledge and handle small sample sizes effectively. In this research, we compare several shrinkage Bayesian estimation methods based on the squared error and the linear exponential loss functions. They were adopted and compared by the Monte Carlo simulation method. The performance of these methods is assessed based on their accuracy and computational efficiency in estimati

... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Journal Of Economics And Administrative Sciences
Investment Perspective According to Behavioral Finance Science
...Show More Authors

The first thing that comes to mind is the highly important question of whether there were some effects of human behavior and its fluctuations on the theories of the efficient market and the contemporary investment portfolio. According to what has been said by the proponents of these two theories; when the optimal return is realized, the efficiency of the market is achieved in terms of perfect information on prices and risk that supposed to be predetermined in a rational way.

he other question that imposed here is “at what time people should be rational in their investments in the security markets ?”. This means that investors are rational for their efforts devoted to utility maximization, which are p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Estimation of Pentraxin-3(PTX3) in Rheumatoid Arthritis Males’ patients (with and without) Type II Diabetes Mellitus in Iraq
...Show More Authors

Rheumatoid arthritis is a chronic inflammatory autoimmune disease its etiology is unknown. The classical autoimmune diseases, have adaptive immune genetic associations with autoantibodies and major histocompatibility complex (MHC) class II such as rheumatoid arthritis (RA), diabetes mellitus type two (DM II). Serum of99 males suffering from RA without DMII as group (G1), 45 males suffering from RA with DM II as group (G2) and 40 healthy males as group (G3) were enrolled in this study to estimation of alkaline phosphates (ALP), C-reactive protein (CRP) and Pentraxin-3(PTX). Results showed a highly significant increase in PTX3 levels in G1 and G2 compared to G3 and a significant decrease in G1comparing to G2. Results also revealed a significa

... Show More
Publication Date
Sat Oct 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Radiopacity of modified microhybrid composite resin:(An in vitro study)
...Show More Authors

Background: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 01 2014
Journal Name
Political Sciences Journal
Foreign direct investment in Iraq and its role in economic development
...Show More Authors

الاستثمار الاجنبي المباشر في العراق ودوره في تحقيق التنمية الاقتصادية

View Publication Preview PDF
Crossref
Publication Date
Wed Jul 13 2016
Journal Name
International Journal Of Mathematics Trends And Technology
Designed Algorithms for Compute the Tenser Product of Representation for the Special Linear Groups
...Show More Authors

The main objective of this paper is to designed algorithms and implemented in the construction of the main program designated for the determination the tenser product of representation for the special linear group.

View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different curing distances on the microhardness of flowable bulk-fill composite materials
...Show More Authors

Background: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Preparation of Electrical Conducting Polymer CompositesFrom Polyvinylchloride (PVC) Resin and StudyingSome its Electrical Properties
...Show More Authors

The D.C electrical and thermoelectrically properties of randomly mixed isolator – electrolyte system as (Al/ PVC – LiF/Al) junction consisting of polyvinyl chloride (PVC)resin reinforced with Lithium Fluoride (LiF) powder were studied. A comparison is made the properties of (PVC) material with varying percentage of (LiF) powder (0%, 30%, 50%, 80%)to find out the effect of reinforcement of isolator material. The composites dissolving in 10ml form tettraHaedroflourn (THF) and Solution were the castled in Petri dish and Laved it dry in the air, The out coming Sample were disc - Like shape of a diameter of about 3cm and thickness reneged between (0.01- 0.018) cm . The composites dissolving in 10ml form tettraHaedroflourn (THF) a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Sorption of Lead, Zinc and Copper from Simulated Wastewater by Amberlite Ir-120 Resin
...Show More Authors

The presence of heavy metals in the environment is major concern due to their toxicity. In the present study a strong acid cation exchange resin, Amberlite IR 120 was used for the removal of lead, zinc and copper from simulated wastewater. The optimum conditions were determined in a batch system of concentration 100 mg/L, pH range between 1 and 8, contact time between 5 and 120 minutes, and amount of adsorbent was from 0.05 to 0.45 g/100 ml. A constant stirring speed, 180 rpm, was chosen during all of the experiments. The optimum conditions were found to be pH of 4 for copper and lead and pH 6 for zinc, contact time of 60 min and 0.35 g of adsorbent. Three different temperatures (25, 40 and 60°C) were selected to investigate the effect

... Show More
View Publication Preview PDF
Crossref (7)
Crossref