Background: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 15 dental implants (Dentium, Implantium) in the traumatic functional implant zone(4), this is the intervention group, the control group (n=11) received 14 dental implants in the same zone. 3 dental implants in 2 subjects were lost, leaving a total of 26 dental implants in 20 patients with 10 patients in each group. All subjects were radiographed with OPG for preliminary assessment and with CT scan for registering bone density in Hounsfield Units. Different dental implant sizes were used according to optimal patients' needs. an informed consent was obtained from the intervention group and the recommended monitoring protocol was followed. Dental implant stability ISQ were recorded using RFA by OsstellTM ISQ for both groups three times: immediately after implant placement (at surgery) and after 8,12 weeks respectively. Results: results showed that the mean implant stability for the intervention group was significantly higher P= 0.01 after 12 weeks in comparison to that of the control group. Simvastatin showed statistically significant effect on implant stability among the intervention group after 8 and 12 weeks (P value for both times <0.001) with the attributed risk percent was 70.8 and 50 respectively. Conclusions: this study concluded that the intervention group had higher implant stability and was ready for functional loading prior to control group and that simvastatin might enhanced and/or accelerated the process of osseointegration. Keywords: Implant stability, Simvastatin, resonance frequency analysis.
The drones have become the focus of researchers’ attention because they enter into many details of life. The Tri-copter was chosen because it combines the advantages of the quadcopter in stability and manoeuvrability quickly. In this paper, the nonlinear Tri-copter model is entirely derived and applied three controllers; Proportional-Integral-Derivative (PID), Fractional Order PID (FOPID), and Nonlinear PID (NLPID). The tuning process for the controllers’ parameters had been tuned by using the Grey Wolf Optimization (GWO) algorithm. Then the results obtained had been compared. Where the improvement rate for the Tri-copter model of the nonlinear controller (NLPID) if compared with
In spite of the disappearing of a clear uniform textbook for teaching ESP at different departments and different colleges in both scientific and humanistic studies, the practitioners at those departments and colleges have to teach translation as one of the important requirements to pass the English language exam. The lack of defined translation activities is a noticeable problem therefore; the problem of teaching translation is diagnosed in that the students lack the ability to comprehend the text in English language and other translation knowledge and skills.
The study aims to suggest a translation strategy and then find out the effect of the translation strategy on ESP learners’ achievement in translation. A sample of 50 stud
... Show MoreThe aim of the present work to study the effect of changing velocity (Reynold's number) on oxygen cathodic polarization using brass rotating cylinder electrode in 0.1, 0.3 and 0.5N NaCl solutions (PH = 7) at temperatures 40, 50 and 600 C. Cathodic polarization experiments were conducted as a function of electrode rotational speed and concentration.
ABSTRACT Background: Blood donation is process obtaining, analyzing, preparing, and preserving blood and its many components essential for life-saving that enhances health and lowers mortality rates. Despite the fact that giving blood is frequently demonstrated to be a voluntary service, certain studies highlight a number of factors that affect blood donations such as Gender, past donor experiences including syncopal reactions, venipuncture pain, anxiety, and donor satisfaction, all have an impact on the decision to donate blood.in addition, one of the main reasons donors reject to donate blood is pain associated with venipuncture. Aim: Evaluate the effectiveness of shotblocker on pain during venipuncture in adult blood donors compared to
... Show MoreThe study aimed to determine the impact of energy for the north and south magnetic poles on the the growth of bacteria isolated from cases of tooth decay, 68 swabs were collected from surfaces of faulty tooth, the detected of Staphylococcus aureus
... Show MorePrevious experimental studies have suggested that hot mixed asphalt (HMA) concrete using hydrated lime (HL) to partially replace the conventional limestone dust filler at 2.5% by the total weight of all aggregates showed an optimum improvement on several key mechanical properties, fatigue life span and moisture susceptibility. However, so far, the knowledge of the thermal response of the modified asphalt concrete and thermal influence on the durability of the pavement constructed are still relatively limited but important to inform pavement design. This paper, at first, reports an experimental study of the tensile fatigue life of HMA concrete mixes designed for wearing layer application. Tests were conducted under three different temperatur
... Show MoreBackground: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show MoreThis review discusses the gingival biotypes, their characteristics, analysis based on the measurement of the dentopapillary complex. Also discuss their response to inflammation, surgery, and ridge healing after tooth extraction, their influence in the behavior of the peri-implant tissue