Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium screws. The tibia of 4 white New Zealand rabbits was chosen as implantation sites. Each tibia of rabbit received two screws, one strontium chloride coated and one hydroxyapatite coated and a total 30 histological sections were obtained for each coating material in each period of time. Histomorphometric analysis was performed to measure new bone formed ratio between implant and original bone, after 2 and 6 weeks healing periods. Results: There was increased in new bone formation ratio for the strontium chloride coated implants than hydroxyapatite coated implants and over the two periods of time. There was an increase in the new bone formation ratio at bone-implant interface with time. Conclusion: Coating commercially pure titanium implant with strontium chloride was more efficient in increasing osseointegration at bone implant interface than hydroxyapatite , which was demonstrated by higher new bone formation and maturation at the two periods of time 2 weeks and 6 weeks after implantation. Keywords: Histomorphometric, commercially pure titanium, strontium chloride, hydroxyapatite.
Objective: Many studies focused on clinical cases such as ovariohysterectomy of bitches and scarcely mentioned the histological features. The present study describes the cytoarchitecture characteristics of a local dog’s mature adult reproductive tract. Materials and Methods: Sixteen samples of uterus and cervix were obtained from local breed bitches to conduct this study. The organs were processed according to routine histopathological protocol and stained with hematoxylin and eosin, Masson’s trichrome, and combined Alcian blue (2.5 pH) and PAS (AB-PAS) stains. Results: The mature endometrium formed numerous short epithelial folds and epithelial crypts composed of mucous cells and cuboidal cells. The core of the endometrium is c
... Show MoreThis paper presents the non-linear finite element method to study the behavior of four reinforced rectangular concrete MD beams with web circular openings tested under two-point load. The numerical finite elements methods have been used in a much more practical way to achieve approximate solutions for more complex problems. The ABAQUS /CAE is chosen to explore the behavior of MD beams. This paper also studies, the effect of both size and shape of the circular apertures of MD beams. The strengthening technique that used in this paper is externally strengthening using CFRP around the opening in the MD beams. The numerical results were compared to the experimental results in terms of ultimate load failure and displace
... Show MoreIn this study, a packed bed was used to remove pathogenic bacteria from synthetic contaminated water. Two types of packing material substrates, sand and zeolite, were used. These substrates were coated with silver nanoparticles (AgNPs), which were prepared by decomposition of Ag ions from AgNO3 solution. The prepared coated packings were characterized using scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy. The packed column consisted of a PVC cylinder of 2 cm diameter and 20 cm in length. The column was packed with silver nanoparticlecoated substrates (sand or zeolite) at a depth of 10 cm. Four types of bacteria were studied: Escherichia coli, Shigella dysenteriae, Pseudomonas aerugi
... Show MoreOne of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th
... Show MoreAlgae have been considered a sources task of biofuels, which is a future alternative to fossil fuels, and this lead the environmental studies concerned with the lifting of curves or growth rates and time of replication of different kinds of algae, as well as algae cells in response to different environmental conditions, whether chemical or physical, to assess their impact on the composition of these cells and the extent of affected components that make up the living, especially fatty acid ,total fats, proteins and carbohydrates, Gbrha. Green Chlorococcum humicola showed a different response when treated with an average of agriculture Chu-10 and Chu-13 which used as control media,Compared with the degree of its response when exposed to e
... Show MoreThe work was carried out in two stages. The first stage concerned
with study of silicon carbide (SiC) ratio (1.5, 2.5, 3.5, and 4.5 wt%)
effect on the Thermal conductivity of polyvinyl chloride (PVC); and
the second stage concerned with the UV – weatherizing (25, 50, and
75 hr), thermal aging (40, 50, and 60 °C), and rain- weatherizing (1,
2.5, and 4 hr) effect on the samples involved. Thermal conductivity
results proved that there was slight increase in thermal conductivity
by (SiC) loading; it increased from 0.17 W/m.K for PVC to 0.19
W/m.K for 4.5% SiC/PVC; where as it was systematically decreased
by UV- weatherizing, thermal aging, and rain- weatherizing. This
property is in a good agreement with gene