Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um particles size, with polyvinyl alcohol powder of 212-300um particle size, as a space holder, by volume ratio (70:30) % respectively. The mixed powder was compacted using punch and die set -specially designed for this study –under 20 bar then sintering at 900 ºC by the use of argon gas. Twenty smooth titanium implants were prepared of (3.2mm in diameter and 8mm in length) by lathing of commercially pure titanium rod as a control group. The implants were examined by X-ray diffraction (XRD) and scanning electron microscope (SEM), as well as estimation of porosity percentage. For each tibia of the 20 white New Zealand rabbits, one implant of each type (one porous in right, and the smooth in left tibia), were inserted through surgical procedure carried under serial condition. Mechanical test was performed to evaluate the bone-implant interface, after (2 and 6 weeks) healing periods . Results: Porous implants were obtained successfully by powder technology with 52% porosity and pore size 210um 17±. The porous implant showed significantly higher removal torque values when compared to smooth implants at the two different intervals of examination (2,6 weeks) , this proved to be statistically highly significant, also a highly significant difference was noticed for the means of the torque removal values in the same group at different implantation , with no evidence of clinical features of inflammatory reaction with both . Conclusions: Powder technology seemed to be particularly advantageous in fabrication of porous titanium. Porous implant show an increasing bone ingrowth compared with the smooth type represented by higher removal torque for both healing periods (2, 6) weeks . Key words: Porous titanium implant, powder technology, removal torque test.
Two tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min−1 (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r
Background: Curve of Spee (CS) is an anteroposterior anatomical curve established by the occlusal alignment of the teeth viewed in the sagittal plane. This occlusal curvature has clinical importance in orthodontics and other fields of dentistry. This study aimed to evaluate the relationship between the CS and dentofacial morphology of different skeletal patterns in both genders. Materials and Methods: Eighty six Iraqi Arab subjects (44females,42 males ) their age ranged from 17 -30 years, classified into: Skeletal I with normal occlusion(15 females and 15 males), skeletal II with CI II div 1 malocclusion (15 females and 15 males) and skeletal III with CI III malocclusion (14 females and 12 males). Forty one variables measured us
... Show MoreBackground: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill
... Show MoreSince its start spreed "Severe acute respiratory syndrome coronavirus 2" was discovered in Wuhan, China.that is chargeable COVID-19, a pandemic virus, has end up a widespread fitness hassle everywhere in the global Over 2.1 million people have been affected. We analyze serum concentration of CD4 marker and CD8 marker depend in COVID-19 sufferers, and to make clear a relationship between these variables and disorder Progression and severity For those purpose, (158) sufferers with COVID-19 (showed with the aid of using polymerase chain reaction) and (22) seemingly wholesome human beings have been protected withinside the present day examine and taken into consideration as a manipulate group. All examine population (sufferers and manipulate) h
... Show MoreForty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,
... Show MoreThe relationship between chronic hepatitis B virus and Helicobacter pylori infection was evaluated to determine, seventy five patients with chronic hepatitis B infection (8-70 years) were investigated. The results were compared with the results of 50 healthy volunteers. Anti-H. pylori antibodies IgA and IgG were measured by Indirect fluorescent antibody test (IFAT) in sera of patients and healthy groups. The percentage of anti-H.pylori IgA antibodies (26.67%) were significantly (P<0.01) higher than healthy control group. While, no significant difference was found between the percentages of anti-H. pylori IgG antibodies (48 %) in patient sera and these kind of antibodies in sera of healthy control group (P > 0.05). The present results indica
... Show MoreBackground: Many structural or functional abnormalities can impair the production of thyroid hormones and cause hypothyroidism.Objectives: to identify the main etiological causes of hypothyroidism among patients visiting Specialized Center for Diabetes and Endocrinology.Methods: This study was conducted in the Specialized Center for Diabetes and Endocrinology on 217 patients with proved hypothyroidism, from 2006 to 2008. Every patient was tested with thyroid function tests, Ultrasound examination, thyroid autoantibodies, fine needle aspiration, radiology of skull, isotopes scan, also checking adrenal and gonadal function. Results: Out of these 217 patients 120 patients have thyroiditis 33 patients had been undergone thyroidectomy. 39 pat
... Show MoreBackground and Aim: The use of food dyes can cause certain diseases, such as anemia and indigestion, along with other disorders, tumors, and even cancer. Therefore, this study aimed to determine the chemical nature and toxicity of some commercial dyes locally used in processed foods compared with standard food dyes. Materials and Methods: Three types of standard and commercial food color additives (Sunset Yellow, Tartrazine, and Carmoisine) were extensively examined. The chemical structures and functional groups of the dyes were evaluated by Fourier-transform infrared (FTIR) spectroscopy. The melting temperatures of the dyes were also determined by chemical thermal analysis. The acute toxicity test to evaluate the standard and commercial
... Show MoreRheumatoid arthritis is an inflammatory chronic disease with an autoimmune pathogenesis. To determine the role of Helicobacter pylori as a trigger agent, twenty five patients with rheumatoid arthritis of ages (15-47) years have been investigated and compared with twenty healthy individuals. All the studied groups were carried out to measure the rheumatoid arthritis (RA) IgM, anti-CCP antibody IgG and IgA by ELISA test and by measured anti-IgG antibody level of H. pylori by using ELISA and IFAT techniques. The present study showed significant differences (P< 0.05) of anti-H. Pylori in sera of RA patients than control group, this lead to suggest that H. pylori had a role in pathogenesis of RA.