Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um particles size, with polyvinyl alcohol powder of 212-300um particle size, as a space holder, by volume ratio (70:30) % respectively. The mixed powder was compacted using punch and die set -specially designed for this study –under 20 bar then sintering at 900 ºC by the use of argon gas. Twenty smooth titanium implants were prepared of (3.2mm in diameter and 8mm in length) by lathing of commercially pure titanium rod as a control group. The implants were examined by X-ray diffraction (XRD) and scanning electron microscope (SEM), as well as estimation of porosity percentage. For each tibia of the 20 white New Zealand rabbits, one implant of each type (one porous in right, and the smooth in left tibia), were inserted through surgical procedure carried under serial condition. Mechanical test was performed to evaluate the bone-implant interface, after (2 and 6 weeks) healing periods . Results: Porous implants were obtained successfully by powder technology with 52% porosity and pore size 210um 17±. The porous implant showed significantly higher removal torque values when compared to smooth implants at the two different intervals of examination (2,6 weeks) , this proved to be statistically highly significant, also a highly significant difference was noticed for the means of the torque removal values in the same group at different implantation , with no evidence of clinical features of inflammatory reaction with both . Conclusions: Powder technology seemed to be particularly advantageous in fabrication of porous titanium. Porous implant show an increasing bone ingrowth compared with the smooth type represented by higher removal torque for both healing periods (2, 6) weeks . Key words: Porous titanium implant, powder technology, removal torque test.
The study aimed to estimate the content of lead and determine the quality of the internal coating of metal cans through electrical conductivity as well as to determine the accuracy of the information card for some types of canned food that available in local markets. The information card test showed that all of these samples contained the name of the food, trade mark, country origin, weight, and components, as was indicated by the company producing in all of them except for the C12 sample which was otherwise, and the batch number was mentioned in all samples except for the C3 and C17 which was not clear and not mentioned in the C21, and the validity period was observed (produce and fini
... Show MoreGypseous soil is a collapsible soil, which causes large deformations in buildings that are constructed on it. Various methods have been used to minimise this effect, such as replacing the gypseous soil or using soil stabilisation (grouting or soil improvement). This study was carried out on four types of gypseous soils that have different properties and various gypsum contents. The testing was carried out on remoulded samples to evaluate the compressibility of gypseous soil under different conditions. The samples were grouted with acrylate liquid. The relationships between the injection pressure and the radius of flow, between time of injection and radius of flow, and between time and quantity of acrylate liquid are investigated on
... Show MoreThe curriculum is a tool of the basic tools that seek through which educational institutions to achieve the objectives of any educational policy, and therefore must be a practical application of curriculum objectives of this policy. If, however, described the separate curricula for educational policy, that would be evidence of planning that leads to failure in achieving the great goals of society. The curriculum does not include the subject of education only, but goes to all the educational experiences that achieve the desired behavioral goals.
When goal-setting study for any of the articles should study the use of the overall goals of the article. And therefore must serve the general goals of academic material and objectives in one d
Till now, isatin derivatives have received a lot of interest in organic and medicinal chemistry due to their significant biological and pharmacological activities. Schiff’s and Mannich bases of isatins are an effective group of heterocyclic derivatives that play a significant role in medicinal chemistry as antimicrobial agents. In light of these facts, new Schiff bases and Mannich bases of isatin were synthesized. The monomer Mannich bases; 3(a-e) have been synthesized by reacting isatin with different secondary amines, piperidine, morpholine, and pyrrolidine, dimethylamine, diphenylamine, separately, and formaldehyde, while the dimer (5) formed by using piperazine and formaldehyde which then react separately with Phenylhydrazine
... Show MoreThis study was conducted to describe a protocol for the callus establishing culture of Lavandula angustifolia plant and estimating their content of volatile oil. The quantity of volatile oil callus tissues was compared with that of leaves production. Callus was induced from leaf explants on Murashige and Skoog medium (MS) supplemented with Naphthalene acetic acid (NAA) and Benzyl adenine (BA) in different concentrations. Maximum callus fresh weight was obtained in the combination of 10 mg/L BA and 3 mg/L NAA which reached 18 g after four weeks. The results of this work showed that the quantity of volatile oil from the highest fresh weight callus was 6 ml compared with quantity of 18g of leaves which gave 0.5 ml. Volatile o
... Show Morewe studied the effect of low level laser therapy (LLLT) using diode laser with wavelength of (790-805) nm in promotion and enhancement of wound healing of episiotomy and to evaluate the analgesic effect of LLLT in reducing the pain sensation caused by the episiotomy wounds. Nineteen women with episiotomy wound were selected and divided into three groups; 1st group (group No.1: control group) given antibiotics without laser therapy, in the 2nd group (group No.2) the wounds were exposed to laser therapy (4 sessions, each session with energy density of 19.90 J /cm2 every other day ) and systemic antibiotics were prescribed for 1 week. In the 3rd group (group No.3) the wounds were exposed to laser therapy (4 sessions, the same as in the 2nd
... Show MoreThis study aimed to identify the changes in total protein in saliva and sera samples of patients with oral squamous cell carcinoma in comparison to those of healthy controls. These changes were followed using electrophoresis (PAGE). Meanwhile, determinations of albumin, globulin and albumin to globulin ratio were carried out on sera samples only.Two groups were the participants in the present study, 18 patients with Oral Squamous Cell Carcinoma (OSCC), and 20 ages and gender matched healthy controls.
Colorectal cancer (CRC) remains a leading cause of cancer-related deaths worldwide, with tumor angiogenesis playing a pivotal role in its progression and metastasis. CD144 (VE-cadherin), a calcium-dependent adhesion molecule, is critical for endothelial cell integrity and has been linked to tumor angiogenesis and cancer stem cell phenotypes. This study aimed to evaluate the immunohistochemical expression of CD144 in benign colorectal lesions, normal adjacent tumor tissue (NRAT), and tumor tissues to elucidate its role in colorectal cancer progression. Multiple techniques, including immunohistochemistry, flow cytometry, Western blot, and qPCR, were used to assess CD144 expression and its association with the VEGF/VEGFR2 signaling pat
... Show MoreTwo tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min−1 (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r
