Background: The main purpose of this study is to find if there is any correlation between the level of C-reactive protein (CRP) in gingival crevicular fluid with its serum level in chronic periodontitis patients and to explore the differences between them according to the probing depth. Materials and methods: Forty seven male subjects enrolled in this study. Thirty males with chronic periodontitis considered as study group whom further subdivided according to probing depth into subgroup 1 with pocket depth ≤6mm, subgroup 2 with pocket depth >6mm. The other 17 subjects considered as controls. For all subjects, clinical examination where done for periodontal parameters plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD) and clinical attachment level (CAL). The gingival crevicular fluid (GCF) were collected using filter paper size 30 from gingival sulcus of the controls and from (138) pocket site (75 sites > 6mm. and 63 ≤ 6mm.). The weight of the GCF was measured by reading the difference in the weight of filter paper before and after absorption of GCF. Crevicular level of CRP was measured calorimetrically. The serum level CRP was measured using latex test. Results: Highly significant difference in the weight of GCF, crevicular and serum level of CRP between chronic periodontitis and control groups. Subgroup 2 got higher scores of weight of GCF and positive record of crevicular and serum CRP compared with subgroup 1 with a non-significant difference. A highly significant difference in the number of sites with positive crevicular and serum CRP compared to the negative number between chronic periodontitis and control groups also between subgroup1 and subgroup 2. Weight of GCF gets a negative significant correlation with GI at control group and subgroup2. Serum level of CRP exhibits a negative significant correlation with PLI for chronic periodontitis and control group and positive significant correlation for GI at subgroup 1. The crevicular CRP get significant negative correlation with GI of subgroup 1. Conclusions: Crevicular fluid is very good marker for the degree of inflammation of the periodontal pocket. The crevicular level of CRP may be considered as a good tool for estimating the systemic effect and predictor for the effect of periodontitis on the general health and the correlation of crevicular with serum CRP aid to high light this effect.
The problem of generated waste as a result of the implementation of construction projects, has been aggravated recently because of construction activity experienced by the world, especially Iraq, which is going through a period of reconstruction, where construction waste represents (20-40%) of the total generated waste and has a negative effect on the environment and economic side of the project. In addition, the rate of consumpted amounts of natural resources are estimated to be about 40% in the construction industry, so it became necessary to reduce waste and to be manage well. This study aims to identify the key factors affecting waste management through the various phases of the project, and this is accom
... Show MoreIschemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc99m MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echo
The modern steer-by-wire (SBW) systems represent a revolutionary departure from traditional automotive designs, replacing mechanical linkages with electronic control mechanisms. However, the integration of such cutting-edge technologies is not without its challenges, and one critical aspect that demands thorough consideration is the presence of nonlinear dynamics and communication network time delays. Therefore, to handle the tracking error caused by the challenge of time delays and to overcome the parameter uncertainties and external perturbations, a robust fast finite-time composite controller (FFTCC) is proposed for improving the performance and safety of the SBW systems in the present article. By lumping the uncertainties, parameter var
... Show MoreThis study was conducted in Baghdad, Iraq from December 2021 to May 2022. The goal was to determine the effect of Toxoplasma gondii on liver function by examining the relationship between Toxoplasma infection and hormones. One hundred and twenty male patients with Chronic liver disease (CLD) (age:14-75 years) and 120 control males (age: 24-70 years) participated in this study. Serum samples were taken from all individuals and were then analysed for anti-Toxoplasma antibodies. Hormonal tests were conducted for all participants which included (Cortisol, testosterone, prolactin, insulin, and thyroid-stimulating hormone TSH). Biochemical tests included (Prothrombin time PT, international normalized ratio INR and albumin); liver enzymes
... Show MoreThe goal of this work is to check the presence of PNS (photon number splitting) attack in quantum cryptography system based on BB84 protocol, and to get a maximum secure key length as possible. This was achieved by randomly interleaving decoy states with mean photon numbers of 5.38, 1.588 and 0.48 between the signal states with mean photon numbers of 2.69, 0.794 and 0.24. The average length for a secure key obtained from our system discarding the cases with Eavesdropping was equal to 125 with 20 % decoy states and 82 with 50% decoy states for mean photon number of 0.794 for signal states and 1.588 for decoy states.
The current study was designed to investigate the occurrence of aflatoxin B1 in thirty two samples of fish feedstuff were collected randomly from some Iraqi local markets using ELISA technique. Aflatoxin B1 was detected in thirty samples and the concentration of toxin ranged from 50 ppb to 1000 ppb.
Microwave and ozone were used for detoxification of aflatoxin B1 from sample with highest concentration (1000 ppb), two degree of temperature and two times (50°C and 100°C for 5 minute and 10 minute to each degree) of microwave, also two doses and two times (2 g and 4 g for 5 minute and 10 minute to each dose) of ozone gas were used.
Degradation of aflatoxin B1 by
... Show MoreA robust and sensitive analytical method is presented for the extraction and determination of six pharmaceuticals in freshwater sediments.
Improving students’ use of argumentation is front and center in the increasing emphasis on scientific practice in K-12 Science and STEM programs. We explore the construct validity of scenario-based assessments of claim-evidence-reasoning (CER) and the structure of the CER construct with respect to a learning progression framework. We also seek to understand how middle school students progress. Establishing the purpose of an argument is a competency that a majority of middle school students meet, whereas quantitative reasoning is the most difficult, and the Rasch model indicates that the competencies form a unidimensional hierarchy of skills. We also find no evidence of differential item functioning between different scenarios, suggesting
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,ind
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -
... Show More