Background: The presence of anatomic variations within the maxillary sinus such as septa has been reported to increase the risk of sinus membrane perforation during sinus elevation procedure for implant placement. This study aimed to measure the septal heights and correlate it with different types of septa. Material and methods: Thirty patients (15 males and 15 females) with partially edentulous maxillae and mean age (35) years were enrolled in this study. Sixty sinuses scanned with Spiral multislice Computed Tompgraphy, septal height measured after evaluation of septal type whether it was primary or secondary. Results: The results showed that 72.5 % of the septa detected were primary and this is statistically significant when compared with the percentage of secondary type (27.5%). There was a statistically significant difference in the height of septa between the two types, and the primary septa were higher. There was no significant difference between septal type and sex. Conclusions: A sound knowledge of maxillary sinus anatomy and anatomic variations such as septa is essential to prevent complication during surgical interventions involving this region.
The performance analyses of 15 kWp (kW peak) Grid -Tied solar PV system (that considered first of its type) implemented at the Training and Energy Research Center Subsidiary of Iraqi Ministry of Electricity in Baghdad city has been achieved. The system consists of 72 modules arranged in 6 strings were each string contains 12 modules connected in series to increase the voltage output while these strings connected in parallel to increase the current output. According to the observed duration, the reference daily yields, array daily yields and final daily yields of this system were (5.9, 4.56, 4.4) kWh/kWp/day respectively. The energy yield was 1585 kWh/kWp/year while the annual total solar irradiation received by solar array system was 198
... Show MoreIn this paper, a Bayesian analysis is made to estimate the Reliability of two stress-strength model systems. First: the reliability of a one component strengths X under stress Y. Second, reliability of one component strength under three stresses. Where X and Y are independent generalized exponential-Poison random variables with parameters (α,λ,θ) and (β,λ,θ) . The analysis is concerned with and based on doubly type II censored samples using gamma prior under four different loss functions, namely quadratic loss function, weighted loss functions, linear and non-linear exponential loss function. The estimators are compared by mean squared error criteria due to a simulation study. We also find that the mean square error is
... Show MoreThe present study aims to detect CTX-M-type ESBL from Escherichia coli clinical isolates and to analyze their antibotic susceptibility patterns. One hundred of E. coli isolates were collected from different clinical samples from a tertiary hospital. ESBL positivity was determined by the disk diffusion method. PCR used for amplification of CTX-M-type ESBL produced by E. coli. Out of 100 E. coli isolates, twenty-four isolates (24%) were ESBL-producers. E. coli isolated from pus was the most frequent clinical specimen that produced ESBL (41.66%) followed by urine (34.21%), respiratory (22.23%), and blood (19.05%). After PCR amplification of these 24 isolates, 10 (41.66%) isolates were found to possess CTX-M genes. The CTX-M type ESBL
... Show MoreIn the present investigation two different types of fiber reinforced polymer composites were prepared by hand lay-up method using three different parameters (curing temperature, pressing load and fiber volume fraction). These composites were prepared from the polyester resin as the matrix material reinforced with glass fibers as first group of samples and mat Kevlar fibers as the second group, both with different volume fractions (4%, 8%, and 12%) of fibers. They were then tested by tensile strength and impact strength. The main objective in this study is to use Taguchi method for predicting the better parameters that give the better tensile and impact strength to the composites, and then preparing composites at
... Show MoreThis research, involved a series of some new compounds containing different hetero cyclic new pentagonal and hexagonal rings, through the reaction of 2-mercapto-3-phenyl-4(3H)quinazolinone (1) with chloroacetylchloride in the presence of potassium hydroxide, and dry dimethylformamide (DMF) as a solvent to obtain the intermediate compound (2). This compound is reacted with different reagents to give four routes, the first route include direct reaction with substituted-2-aminobenzothiazole under certain conditions to give new compounds (3-9). The second route involved condensation compound (2) with 5-substituted-2-amino-1,3,4-oxadiazole in the presence of potassium carbonate anhydrous to give new compounds (10-13).while the third route inv
... Show MoreThis paper aims to evaluate the hydraulic characteristics of the aquifer between Al-khassa dam and Kirkuk structure, Kirkuk/ NE Iraq. Pumping tests applied for selected wells in the area to evaluate the hydraulic characteristics of the aquifer, special distribution of the water table and groundwater movement direction of the groundwater, the hydraulic properties results of five single pumping test in the study area showed that the transmissivity (T) is ranged between (2.01 to 7. 5 m2/day ), storage coefficient (Sc) ranged (6.4 * 10-3 to 7.3 * 10-2) and the hydraulic conductivity (K) is ranged between (0.025 to 0.35 m/day) that calculated by Winlog software, groundwater discharge of the area is equal to
... Show MoreBackground: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)
... Show More