Preferred Language
Articles
/
jbcd-593
Evaluation of shear bond strength of artificial teeth to heat cure acrylic and high impact heat cure acrylic using autoclave processing method
...Show More Authors

Background: Debonding and fracture of artificial teeth from denture bases are common clinical problem, bonding of artificial teeth to heat cure acrylic and high impact heat cure acrylic denture base materials with autoclave processing method is not well known. The aim of this study was to evaluate the effect of autoclave processing method on shear bond of artificial teeth to heat cure denture base material and high impact heat cure denture base material. Materials and methods: Heat polymerized (Vertex) and high impact acrylic (Vertex) acrylic resins were used. Teeth were processed to each of the denture base materials after the application of different surface treatments. The sample (which consist of artificial tooth attached to the denture base at 45 degree) are consist of (80) artificial teeth from the same model of central incisor, they were prepared , treated and bonded to the conventional heat cured and high impact acrylic denture base material then processed. Control group (Group A 40 samples) in which acrylic resins PMMA cured by conventional water- bath processing technique (74°C for 1.5 hours then boil for 30 minutes),the group was subdivided to 20 samples heat cure acrylic and 20 samples high impact acrylic. Experimentalgroups (Group B 40 samples) in which acrylic resins was cured by autoclave at 121°C, 210KPa. For 30min.the group subdivided to 20 samples heat cure acrylic and 20 samples high impact acrylic. For each subgroup, the 20 samples were subdivided according to surface treatment into: 1-Five acrylic teeth without any surface treatment (control). 2- Five acrylic teeth with diatoric preparation (retention grooves). 3- Five acrylic teeth conditioned with thinner. 4- Five acrylic teeth with retention grooves and thinner. Results: Statistical analysis revealed that chemical and mechanical treatment of acrylic teeth improved the shear bond with heat cure and high impact acrylicalsoautoclave processing improvedthe shear bond with acrylic teeth in high impact acrylic. Conclusion: Autoclave polymerization is suggested as alternative method for processing denture base resins. Autoclave polymerization can be easily performed in laboratory conditions. In High Impact Acrylic, there were highly significant differences of autoclave processing technique compared with water bath regarding the shear bond strength with acrylic teeth.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Evaluation The Efficiency And Effectiveness of The Iraq stock Exchange -An Empirical Study From July 2004 to March 2008–
...Show More Authors

 The aim of this study was to provide an overall assessment to the efficiency of the Iraq stocks exchanges (ISE) through specifying well –known models .First, Fama's efficient market hypothesis as a contrary concept to the random walk hypothesis, was performed and it has been found that ISE follows the random process, so the price of the shares can't be predicated on the basis of past information. Second,we use a multifactor model, which so named multiple regression, to explore the link between ISE  and the main economic indicators. our empirical analysis finds that every weak associations exists between major ISE measures and main economic indicators.

View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Azerbaijan Pharmaceutical And Pharmacotherapy J
Evaluation of Nurses’ Practices and Perceived Barriers Related to Pain Assessment in Critically Ill Patients at Baghdad Teaching Hospitals
...Show More Authors

Introduction: Inadequate pain assessment and management is a problem in hospitalized patients that impairs their wellbeing. Intensive care unit nurses’ pain practices are affected by several barriers and enablers. Objectives: The objectives of this study were to determine the level of nurses’ practices and perceived barriers related to pain assessment in critically ill patients. Methodology: A cross-sectional design study was used. Purposive sampling technique was employed, including 100 nurses recruited from 8 intensive care units in Baghdad city, Iraq. The study was conducted from September 1st to October 20th, 2022. The pain assessment and management for critically ill patients survey was used to collect data. Descriptive sta

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 01 2006
Journal Name
J Bagh College Of Dentistry
Assessment of diametral tensile strength and microhardness of Glass ionomer reinforced by different amounts of Hydroxyapatite
...Show More Authors

Back ground: Glass ionomer materials lack resistance to wear and pressure and are susceptible to moisture during the initial stages of setting and dehydration. So this study was done to assess diametral tensile strength and microhardness of glass ionomer reinforced by different amounts of hydroxyapatite. Materials and methods: In this study a hydroxyapatite material was added to glass monomer cement at different ratios: 10%, 15%, 20%, 25% and 30% (by weight). The diametral tensile strength test described by the British standard specification for zinc polycarboxylate cement was used in this study and the microhardness test was performed using Vickers microhardness testing machine and the microhardness values were calculated and statistical c

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Investigations on the Impact of Using Elliptic Groynes on the Flow in Open Channels
...Show More Authors

This paper presents a numerical simulation of the flow around elliptic groynes by using CFD ‎software. The flow was simulated in a flume with 4m long, 0.4m wide, ‎and 0.175m ‎high ‎‎with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow ‎‎inlet with a ‎constant the Groyne height of 10cm and a 1cm thickness, and the ‎width of Groynes equals ‎7cm‎. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of ‎0.0057‎m3/sec. The CFD ‎model showed a good ability to simulate the flow ‎around ‎Groynes with ‎ good accuracy. The results of ‎CFD software showed that when using double elliptic Groy

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Advanced Research In Dynamical And Control Systems
The impact of node density over routing protocols in manet by using NS-3
...Show More Authors

Scopus (5)
Scopus
Publication Date
Fri Aug 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of enamel color alteration between bonded and free unbonded surfaces of maxillary anterior teeth after fixed orthodontic therapy (A prospective clinical study)
...Show More Authors

Background: The purpose of this study is to compare the color changes between the bonded middle third and the unbonded gingival and incisal thirds, fallowing fixed orthodontic treatment Material and method: The color parameter l, a, b has been recorded for each thirds in upper anterior teeth by mean of easy shad device. The has been calculated for gingival, middle and incisal thirds for the upper anterior teeth in 34 patient, 17 males and 17femals, those subject undergone fixed orthodontic treatment Results: The in middle bonded third is highly significant higher than that in incise and gingival thirds p<0.01 because the middle third isn’t expose to oral fluid and dental brushing since it covered by the bracket. Also there

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
A New Green Approach of CFIA Technique for Direct Assay with a High Throughput of Sulfamethoxazole Drugs Using Condensation Reaction with NQS Agent
...Show More Authors

A new design of manifold flow injection (FI) coupling with a merging zone technique was studied for sulfamethoxazole determination spectrophotometrically. The semiautomated FI method has many advantages such as being fast, simple, highly accurate, economical with high throughput . The suggested method based on the production of the orange- colored compound of SMZ with (NQS)1,2-Naphthoquinone-4-Sulphonic acid Sodium salt in alkaline media NaOH at λmax 496nm.The linearity range of sulfamethoxazole was  3-100  μg. mL-1, with (LOD) was 0.593 μg. mL-1 and the RSD% is about 1.25 and the recovery is 100.73%. All various physical and chemical parameters that have an effect on the stability and development of

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Sat Sep 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Early impact of fixed orthodontic therapy on gingival health status in relation to weight status
...Show More Authors

Background: fixed orthodontic appliances deleterious influence on gingival health is well documented. Association between weight status and gingival health is presented in many studies. This study aimed to evaluate how early the impact of fixed orthodontic therapy on patients` gingival health, and if there are differences of that impact among different weight status groups. Materials and Methods: Sample consisted of 54 patients (25 males, 29 females; age limits are 16 -18 years) going under the course of treatment with fixed orthodontic appliance. Patients were categorized according to their Body Mass Index (BMI) into 3 weight status groups considering WHO charts in 2007 (underweight, normal weight, overweight and obese), then determinat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 25 2018
Journal Name
Earthquake And Structures
Response of circular footing on dry dense sand to impact load with different embedment depths
...Show More Authors

Scopus (7)
Scopus
Publication Date
Wed Oct 04 2023
Journal Name
Exergy - New Technologies And Applications
High Synthetic Image Coding System
...Show More Authors

Compressing an image and reconstructing it without degrading its original quality is one of the challenges that still exist now a day. A coding system that considers both quality and compression rate is implemented in this work. The implemented system applies a high synthetic entropy coding schema to store the compressed image at the smallest size as possible without affecting its original quality. This coding schema is applied with two transform-based techniques, one with Discrete Cosine Transform and the other with Discrete Wavelet Transform. The implemented system was tested with different standard color images and the obtained results with different evaluation metrics have been shown. A comparison was made with some previous rel

... Show More
View Publication
Crossref