Preferred Language
Articles
/
jbcd-592
Evaluation of marginal gap at the composite/enamel interface in Class II composite resin restoration by SEM after thermal and mechanical load cycling (An in vitro comparative study)
...Show More Authors

Background: This study compared in vitro the marginal adaptation of three different, low shrink, direct posterior composites Filtek™ P60 (packable composite), Filtek™ P90 (Silorane-based composite) and Sonic fill™ (nanohybrid composite) at three different composite/enamel interface regions (occlusal, proximal and gingival regions) of a standardized Class II MO cavity after thermal changes and mechanical load cycling by scanning electron microscopy. Materials and methods:Thirty six sound human maxillary first premolars of approximately comparable sizes were divided into three main groups of (12 teeth) in each according to the type of restorative material that was used: group (A) the teeth were restored with Filtek™ P60 and single bond™ Universal adhesive using horizontal incremental technique, group (B)the teeth were restored with Filtek™ P90 and P90 system adhesive using horizontal incremental technique and group (C) the teeth were restored with Sonic fill™ composite and single bond™ Universal adhesive using bulk technique.After specimens were stored in distilled water at 37°C for 7 days, all specimens were subjected to thermocycling at (5° to 55 °C), then submitted to mechanical load cycling (intermittent axial force of 49N and a total of 50.000 cycles). The specimens were observed under scanning electron microscope at (2000 X) to measure marginal gap width (the distance between the dental wall and the restoration) at occlusal, proximal and gingival regions in micrometer using Tescan software, version 3.5. Data were analyzed statistically by one way ANOVA test and least significant difference tests. Results:The results showed that the silorane-based posterior composite (Filtek™ P90) showed significantly the least marginal gap width at the occlusal, proximal and gingival regions after the application of thermal changes and mechanical load cycling in comparison to the two methacrylate-based posterior composite Filtek™ P60 (packable) and the Sonic fill™ (nano-hybrid). Sonic fill™ bulk fill composite that relied on the vibration concept to lower the viscosity of high filler loaded composite material showed significantly lesser marginal gaps width at occlusal, proximal and gingival composite/enamel interface regions in comparison with Filtek™ P60 (packable composite) using horizontal incremental technique. The silorane-based composite (Filtek™ P90) showed non-significant difference in marginal gaps width at the three different regions. While, both methacrylate based Filtek™ P60 and Sonic fill™ composite showed significantly lesser marginal gap width at the occlusal region in comparison with gingival regions. Conclusion: None of the low-shrinkage composite restorative materials tested in this study totally prevented micro-gap formation at composite/enamel interfaces of Class II MO cavity.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and evaluation of B-cyclodextrin Based Nanosponges of 5- Fluorouracil by Using Ultrasound Assisted Method
...Show More Authors

 

CD-nanosponges were prepared by crosslinking B-CD with diphenylcarbonate (DPC) using ultrasound assisted technique. 5-FU was incorporated with NS by freeze drying, and the phase solubility study, complexation efficiency (CE) entrapment efficiency were performed. Also, the particle morphology was studied using SEM and AFM. The in-vitro release of 5-FU from the prepared nanosponges was carried out in 0.1N HCl.

5-FU nanosponges particle size was in the nano size. The optimum formula showed a particle size of (405.46±30) nm, with a polydispersity index (PDI) (0.328±0.002) and a negative zeta potential (-18.75±1.8). Also the drug entrapment efficiency varied with the CD: DPC molar ratio from 15.6 % to 30%. The SEM an

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (5)
Scopus Crossref
Publication Date
Thu Dec 09 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and In vitro Characterization of Aceclofenac Nanosuspension (ACNS) for Enhancement of Percutaneous Absorption using Hydrogel Dosage Form
...Show More Authors

         Aceclofenac (AC) is an orally active phenyl acetic acid derivative, non-steroidal anti-inflammatory drug with exceptional anti-inflammatory, analgesic and antipyretic properties. It has low aqueous solubility, leading to slow dissolution, low permeability and inadequate bioavailability. The aim of the current study was to prepare and characterize AC-NS-based gel to enhance the dissolution rate and then percutaneous permeability. NS.s were prepared using solvent/antisovent precipitation method at different drug to polymer ratios (1:1, 1:2, and 1:3) using different polymers such as poly vinyl pyrrolidone (PVP-K25), hydroxy propyl methyl cellulose (HPMC-E5) and poloxamer® (388) as stabilizer

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (3)
Scopus Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Evaluation of Patients with Liver Injuries Treated by Perihepatic Gauze Packing
...Show More Authors

Background: The liver is one of the most common organs
injured after blunt abdominal trauma. The control of severe
hemorrhage remains a problem.
Methods: One-hundred thirty-eight patients diagnosed as
liver injury between 09/2003 and 08/2006 had been evaluated
prospectively in Al- Kindy Teaching Hospital.
A distinction was made between hemodynamically stable and
unstable patients. Different modalities of surgical procedures
were done concentrating on perihepatic gauze packing.
Results: (60 out of 138) patients included in the study were
clinically evaluated as hemodynamically stable. The average
abbreviated injury severity score (ISS) was 25. Twenty
patients underwent abdominal surgery. In 12 of them

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Biomechanical evaluation of porous titanium implants (CpTi) fabricated by powder technology
...Show More Authors

Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 02 2025
Journal Name
Journal Of Physical Education
A comparative analysis , for some Elkinmetekih variables , in the performance of the skill (Nick shot the front reverse ) , between the players of the Iraqi team and the Egyptian , for young people in squash
...Show More Authors

View Publication
Publication Date
Thu Nov 01 2018
Journal Name
Italian Journal Of Vascular And Endovascular Surgery
Retroperitoneal versus transperitoneal approach for aortoiliac occlusive disease: a comparative study
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Dental Aerosol Hazard Prevention with Pre-procedural Antiseptic Mouthwashes (Comparative Study)
...Show More Authors

Background: One of the recommended methods for reducing aerosol contamination during the daily regular usage of high-speed turbine and ultrasonic scaling is the use of preprocedural mouth rinse. Several agents have been investigated as a preprocedural mouth rinse. Chlorhexidine significantly reduce the viable microbial content of aerosol when used as a preprocedural rinse. Studies have shown that cetylpridinum chloride (CPC) mouthwash is equally effective as chlorhexidine in reducing plaque and gingivitis. This study compared the effect of 0.07% CPC to 0.2% chlorhexidine gluconate (CHX) as preprocedural mouth rinses in reducing the aerosol contamination by high-speed turbine. Materials and Methods: 36 patients were divided into three gro

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Oct 08 2008
Journal Name
Journal Of Kerbala University
Viscosity and Volumetric studies of some amino acids in solutions at different temperatures.
...Show More Authors

Publication Date
Thu Jan 15 2009
Journal Name
Journal Of Kerbala University
Viscosity and Volumetric studies of some amino acids in solutions at different temperatures
...Show More Authors

Densities ρ and viscosities η for several concentrations of amino acids (Serine, Cysteine and Threonine) at different temperatures (298.15, 303.15 and 308.15K) have been measured. On the basis of these data, the apparent molal volumes v , partial molal volumes at infinite dilution v , slope Sv , Gibbs free energy of activation for viscous flow of solution ∆G1,2 and Jones – Dole Bcoefficients were calculated the nature of solute-solvent and solute-solute interactions have been discussed in terms of the values of v , v , Sv and B-coefficents

Publication Date
Mon Jan 02 2017
Journal Name
Al-academy
The semiology of culture and the sign variable in a theatre performance: Iraqi theatre as an example
...Show More Authors

The culture of theatre performance has a vital role in the process of reading the linguistic and visual signs of the performance. And the process of transforming a theatre performance from its original context into a new hosting cultural context starts from the actual reading of the text. Directors derives their new signs out of his personal culture, depending on the society where they lives and the culture that forms the social conventions, traditions and beliefs. The text is usually written within its own historical and temporal culture. The process of its production usually takes it away from its original culture, when it interprets the codes of the original writer and their visual and linguistic signs and instils new alternative sign

... Show More
View Publication Preview PDF
Crossref