Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.
Background: Normal thyroid function is essential for neonatal growth and brain development. In a newborn infant with severe disease, endocrine regulation of hormones can be affected by abnormal metabolism. The assessment of thyroid parameters results in the recognition of a dysfunction and its association with disease severity. Objective: This study aimed to assess thyroid function profiles in critically ill neonates in the neonatal intensive care unit (NICU) compared with healthy controls. Additionally, we aimed to detect the presence of TD and its possible association with critical illness. Methods: A case-control study was performed in 100 neonates, comprising 50 sick neonates and 50 healthy controls. We measured thyroid functio
... Show MoreST Alawi, NA Mustafa, Al-Mustansiriyah Journal of Science, 2013
The aim of this paper was to investigate the removal efficiencies of Zn+2 ions from wastewater by adsorption (using tobacco leaves) and forward osmosis (using cellulose triacetate (CTA) membrane). Various experimental parameters were investigated in adsorption experiment such as: effect of pH (3 - 7), contact time (0 - 220) min, solute concentration (10 - 100) mg/l, and adsorbent dose (0.2 - 5)g. Whereas for forward osmosis the operating parameters studied were: draw solution concentration (10 - 150) g/l, pH of feed solution (4 - 7), feed solution concentration (10 - 100) mg/l. The result showed that the removal efficiency by using adsorption was 70% and the removal efficiency by using forward osmosis was 96.2 %.
... Show MoreBackground: The present in-vitro study was undertaken to evaluate and compare fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different bulk fill composite restorations (EverX posterior, Alert, Tetric EvoCeram Bulk Fill, and SDR). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Forty-eight human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into six groups of eight teeth each (n=8): (Group 1) intact control group, (Group 2) unrestored teeth with
... Show MoreCore decompression is one of the commonest used techniques in the handling of osteonecrosis of the pre-collapsed head of the femur. Core decompression had succeeded in preserving the hip joint and delaying the requisite for total hip replacement, but it had failed in the induction of osteogenesis in the necrotic area, thus augmenting core decompression with biological agents to induce osteogenic activity. To assess the effects of platelet-rich plasma in non-traumatic avascular necrosis of the hip joint (early stage) after core decompression. Interventional comparative study for twenty-four patients (32 hip joints) with AVN of the head of the femur was involved in this prospective study, and they were separated into two groups of 16
... Show MoreA nano-sensor for nitrotyrosine (NT) molecule was found by studying the interactions of NT molecule with new B24N24 nanocages. It was calculated using density functionals in this case. The predicted adsorption mechanisms included physical and chemical adsorption with the adsorption energy of −2.76 to −4.60 and −11.28 to −15.65 kcal mol−1, respectively. The findings show that an NT molecule greatly increases the electrical conductivity of a nanocage by creating electronic noise. Moreover, NT adsorption in the most stable complexes significantly affects the Fermi level and the work function. This means the B24N24 nanocage can detect NT as a Φ–type sensor. The recovery time was determined to be 0.3 s. The sensitivity of pure BN na
... Show MoreBackground: Osteoarthritis is a chronic pathology of the joints causing disability and morbidity. Diacerein is a disease-modifying agent indicated for osteoarthritis management with enhanced performance and have much lower side effects profile than conventional non-steroidal anti-inflammatory drugs. Oral administration of Diacerein is associated with a laxative effect, thus causing treatment discontinuation. Aim: This study aimed to evaluate the activity of Diacerein novasome-based transdermal gel compared with standard oral treatment in the management of induced osteoarthritis in a rat model. Materials and methods: A single intra-articular injection of monosodium iodoacetate was administered to the left knee joint, resulting in the develop
... Show MoreIt has been a well-known practice to use seeds and the essential oil of Carum copticum as a strongly antiseptic , antispasmodic , aromatic , bitter , diaphoretic , digestive , diuretic , expectorant and tonic. Also used for cure influenza, asthma, and rheumatoid arthritis. To our knowledge it will be the first time to use the seeds of this herb as a urinary tract stone lithotripsy.This research aimed to the use of these seeds as a lithotripsian against different types of urinary stones and determine the efficiency of these preparation against which types of stone.A liquid solution was prepared from dissolving the seeds powder in cow milk and then concentration this prep
... Show MoreThis research aims primarily to highlight personal tax exemptions A comparative study with some Arab and European regulations. And by conducting both theoretical comparative analyses. Most important findings of the study is the need to grant personal and family exemptions that differ according to the civil status of the taxpayer (single or married). In other words, the exemption increases as the number of family members depend on its social sense. Also taking into account some incomes that require a certain effort and looking at the tax rates, it is unreasonable for wages to be subject to the same rates applied to commercial profits.