Background: Lymphomas are a group of diseases caused by malignant lymphocytes that accumulate in lymph nodes and cause the characteristic clinical features of lymphadenopathy. Intercellular adhesion molecule-1 (ICAM-1) (CD54) is a transmembrane glycoprotein belonging to the immunoglobulin superfamily of adhesion molecules. Cortactin was first identified as one of the major substrates for src kinase. because it localized to Cortical actin structures, The aims of this study was to evaluate and compare the immunohistochemical of ICAM-1 expression as cell adhesion molecule marker and Cortactin expression as invasive marker. Material and Methods: This study was performed on (68) formalin-fixed, paraffin-embedded blocks, histopathologically diagnosed as lymphoma (head and neck lesions).Immunohistochemical staining of ICAM-1and Cortactin was performed on each case of the study sample. Results: The expression of ICAM-1 was membranous and cytoplasmic, the study cases showed a 98.5% positive reaction to ICAM-1, score 2 was the most common and found in 69.1% of all cases.The expression of Cortactin was cytoplasmic, 98.5% of cases expressed positive reactions to Cortactin, score 1 was the most common and found in 42.7% of all cases. Conclusion: Although the two markers showed a higher expression rate in all lymphomas (both HL and NHL) in this study, they can't be used to differentiate between them, nor can be used to differentiate between the subtypes of both HL and NHL. The high ICAM-1positive expression clarified that in addition to its role in cell-cell and cell-stromal interactions, it participates in proliferation, differentiation and invasion of malignant lymphoma cells.The present study is the first one that used Cortactin as an invasive marker for lymphoma.
The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show MoreBackground: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo
... Show MoreMixed ligand of Co and Ni (II) complexes were prepared from [5-(p-nitrophenyl)-4/-phenyl-1,2,4-triazole-3-dithiocarbamato hydrazide](TRZ.DTC) as primary ligand and 2,2'-bipyridyl (bipy) as a co-ligand with metal salts. These complexes were analytically and spectroscopically characterized in solid state by elemental analyses, flame atomic absorption, magnetic susceptibility and molar conductance measurements, as well as by UV–Vis and FTIR spectroscopy. Infrared, ultra violet spectra reveal a bidentate coordination of the two ligands with metal ions 1:1:1 mole ratio. Room temperature magnetic moments and solid reflectance spectra data indicate paramagnetic complexes with five-coordinate square pyramidal geometry for nickel (II) comple
... Show MoreIn this study, a one-dimensional model represented by Butler-Volmer-Monod (BVM) model was proposed to compute the anode overpotential and current density in a mediator-less MFC system. The system was fueled with various organic loadings of real field petroleum refinery oily sludge to optimize the favorable organic loading for biomass to operate the suggested system. The increase in each organic loading showed higher resistance to electrons transport to the anode represented by ohmic loss. On the contrary, both activation and mass transfer losses exhibited a noticeable decrement upon the increased organic loadings. However, current density was improved throughout all increased loads achieving a maximum current density of 5.2 A/m3
... Show MoreBreast cancer is the most common malignancy affecting women's health, with an increasing incidence worldwide. This study aimed to measure the intracellular concentration of the hypoxia-inducible factor 1 α (HIF-1α), tumor suppression protein p53, and estradiol (E2) in tumor tissues of adult females with breast cancer and their relation to tumor grade, tumor size, and lymph node metastases (LNM). The study was conducted on 65 adult female participants with breast mass admitted to the operating theater in Al-Hussein Teaching Hospital and Al-Habboby Teaching Hospital in Nasiriyah, Iraq, from January to November 2021. Fresh breast tumor tissues were collated and homogenized for intracellular biochemical analysis using the enzyme-linked immuno
... Show More
For criminal investigations, fingerprints remain the most reliable form of personal identification despite developments in other fields like DNA profiling. The objective of this work is to compare the performance of both commercial charcoal and activated carbon powder derived from the Alhagi plant to reveal latent fingerprints from different non-porous surfaces (cardboard, plain glass, aluminum foil sheet, China Dish, Plastic, and Switch). The effect of three variables on activated carbon production was investigated. These variables were the impregnation ratio (the weight ratio of KOH: dried raw material), the activation temperature, and the activation time. The effect factors were investigated using Central Composite Design
... Show MoreFor criminal investigations, fingerprints remain the most reliable form of personal identification despite developments in other fields like DNA profiling. The objective of this work is to compare the performance of both commercial charcoal and activated carbon powder derived from the Alhagi plant to reveal latent fingerprints from different non-porous surfaces (cardboard, plain glass, aluminum foil sheet, China Dish, Plastic, and Switch). The effect of three variables on activated carbon production was investigated. These variables were the impregnation ratio (the weight ratio of KOH: dried raw material), the activation temperature, and the activation time. The effect factors were investigated using Central Composite Design (CCD) softwa
... Show MoreThe effect of the aqueous extract of fenugreek seeds (Trigonella Foenum Graecum L.), Rhodium complex (?) with formula [RhL2CLH2O].1 1/2 ETOH and palladium (?) [pdl2].2ETOH,where L=2-hydroxy phenyl piperonalidine was studied on two cancer cell lines. The first cell line was intestine cancer of female albino mice (L20B), the second one was Rhabdomysarcomas (RD)cell line in human. The activity of the new complexes and the aqueous extract was compared to the well-known anticancer drug (cis-platin) by utilizing the in vitro system. The cell lines were treated with four concentrations of cis-platin 31.25,62.5,125 and 250 ?g/ml for 72 hour exposure time. The same concentrations were used with extract and the new complexes. This study showed that t
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show More