Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
In this study, an unknown force function dependent on the space in the wave equation is investigated. Numerically wave equation splitting in two parts, part one using the finite-difference method (FDM). Part two using separating variables method. This is the continuation and changing technique for solving inverse problem part in (1,2). Instead, the boundary element method (BEM) in (1,2), the finite-difference method (FDM) has applied. Boundary data are in the role of overdetermination data. The second part of the problem is inverse and ill-posed, since small errors in the extra boundary data cause errors in the force solution. Zeroth order of Tikhonov regularization, and several parameters of regularization are employed to decrease error
... Show MoreThis research investigates manganese (Mn) extraction from Electric Arc Furnace Steel Slag (EAFS) by using the Liquid-liquid extraction (LLE) method. The chemical analysis was done on the slag using X-ray fluorescence, X-ray diffraction, and atomic absorption spectroscopy. This work consisted of two parts: the first was an extensive study of the effect of variables that can affect the leaching process rate for Mn element from slag (reaction time, nitric acid concentration, solid to liquid ratio, and stirring speed), and the second part evaluates the extraction of Mn element from leached solution. The results showed the possibility of leaching 83.5 % of Mn element from the slag at a temperature of 25°C, nitric acid co
... Show MoreThis study was conducted on a sample of commercial banks in Iraq, chosen according number of considerations for twenty banks, contained two public banks and eighteen private banks. &
... Show MoreSpatial data analysis is performed in order to remove the skewness, a measure of the asymmetry of the probablitiy distribution. It also improve the normality, a key concept of statistics from the concept of normal distribution “bell shape”, of the properties like improving the normality porosity, permeability and saturation which can be are visualized by using histograms. Three steps of spatial analysis are involved here; exploratory data analysis, variogram analysis and finally distributing the properties by using geostatistical algorithms for the properties. Mishrif Formation (unit MB1) in Nasiriya Oil Field was chosen to analyze and model the data for the first eight wells. The field is an anticline structure with northwest- south
... Show MoreBackground: Ostеoporosis is a systеmic disеasе of thе bonе that is charactеrizеd by rеducеd bonе mass, which lеads to incrеasеd bonе fragility and fracturеparticularly in postmеnopausal womеn.Thе aims of study was toеvaluatе thе rеlationship bеtwееn mandibular radiomorphomеtric indicеs obtainеd on digital panoramic radiographswith thе bonе minеral dеnsitiеs of thе lumbar spinееvaluatеd using dual-еnеrgy X-ray absorptiomеtry (DXA) scan, in a population of ostеoporotic and non-ostеoporotic fеmalеs. Matеrials and mеthods: In panoramic imagеs obtainеd from 60 fеmalе individuals dividеd еq
... Show MoreIntroduction/Aim. Seminal fluid analysis (SFA) plays a crucial role in helping infertility clinics diagnose the underlying reason of male infertility. The aim of the study was to investigate seminal fluid patterns of male partners of an infertile couple with apparently fertile female partners. Materials and methods. A cross-sectional study was conducted between January 2019 and December 2022. Patients were attending consultations for delayed conception for more than 12 months with apparently fertile female partner. Results. Four hundred fifty-three patients were included in the study. The distribution of patients according to age groups showed that 277 patients were young, aged 21 - 30 years (61%). Two hundred sixty-two (58%) patien
... Show MoreDBN Rashid, International Journal of English Linguistics, 2019 - Cited by 2
BN Rashid