Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
The aim of this work is to study the factors that affect the welding joint of dissimilar metals. Austenitic stainless steel-type AISI (316L) with a thickness of (2mm) was welded to carbon steel (1mm) using an MIG spot welding. The filler metal is a welding wire of the type E80S-G (according to AWS) is used with (1.2mm) diameter and CO2 is used as shielding gas with flow rate (7L/min) for all times was used in this work.
The results indicate that the increase of the welding current tends to increase the size of spot weld, and also increases the sheer force. Whereas the sheer force increased inversely with the time of welding. Furthermore, the results indicate that i
... Show MoreTotal of 170 samples were collected from Al-Chibayish Marsh reality in Dhi-Qar governorate southern of Iraq to study the epidemology of viral hepatitis in these areas and to detect the type of hepatitis viruses which include A ,B,C,D .The percentage of hepatitis A was 1.17% and most of them below age of ?10 (66.6%) while infection with hepatitis B account 5.29% and includes all age groups. There was no detected cases of hepatitis C,D. The laboratory study showed that the incidence of hepatitis B higher in male (4.11%) compared to female ( 2.35%)
The semantic analysis is characterized by its ability to describe the communicative pattern and its high efficiency in questioning its semantic manifestations and its deliberative purposes, which helped to understand the symbolic, contextual and cultural manifestations of the structure of the pattern, whether verbal or nonverbal. In order to highlight the role of the semiautomatic approach and its application to a sample of slogans collected from "media, social networking sites, in-kind views, media institutions, etc." to study the components and analyze the contents and highlight the signs. His boat logo is not just uttered as a linguistic transmission of a message, but as a political Tghieria actually . For example, the slogan "People Wan
... Show MoreThe importance of knowledge is represented in the use of various sources of information, the corresponding to the same level of importance is the use of modern means and technologies in the delivery and investment of these sources to the beneficiaries, among these means and technologies are the multimedia that deal with most of the human senses, but the most important of which is sight and hearing, if these are invested the means in the field of education will give many positive results, such as the speed of receiving information, its clarity, and its freedom from impurities and influences, as well as its stability in memory as it is based on nderstanding, not memorization. On this basis, the experience of supporting the education process
... Show MoreGestational Diabetes Mellitus (GDM) is the most common metabolic disorder that found during gestation and is define as hyperglycemia of variable severity with onset or first recognition during gestation that does not clearly characterize any form of the preexisting diabetes (American Diabetes Association [1]). It affects approximately 16.5% of pregnancies worldwide (Plows, et al.[2]). The placenta is an organ that connects the mother and her fetus during pregnancy (Gul, et al.[3]). In the placenta, glucose can be transformed into glycogen for storage by either glycogen synthase or using glycogenin as a prime. However, the function of glycogen deposition stays a matter of debate, it may be the source of fuel for placenta itself or the storag
... Show MoreThe influence of silver doped n-type polycrystalline CdTe film with thickness of 200 nm and rate deposition of 0.3 nm.s -1 prepared under high vacuum using thermal co-evaporation technique on its some structural and electrical properties was reported. The X- ray analysis showed that all samples are polycrystalline and have the cubic zinc blend structure with preferential orientation in the [111] direction. Films doping with impurity percentages (2, 3, and 4) %Ag lead to a significant increase in the carrier concentration, so it is found to change from 23.493 108 cm -3 to 59.297 108 cm -3 for pure and doped CdTe thin films with 4%Ag respectively. But films doping with impurity percentages above lead to a significant decrease in the electrica
... Show MoreThis book presents the problem of tooth decay due to bacteria Streptococcus mutans one of methods of treatment using 3 extracts of S. persica (miswak) (aqueous, acetone and methanol) and prove its effectiveness and its impact on the gtf (B, C, and D) genes that code the glucosyltransferase (Gtf) enzymes that cause decay membrane compared to the usual means used for the prevention of tooth decay