Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
This work aimed to design and testing of a computer program – based eyeQ improvement, photographic memory enhancement, and speed reading to match the reading speed 150 – 250 word per minute (WPM) with the mind ability of processing and eye snap shooting 5000WPM . The package designed based on Visual Basic 6. The efficiency of the designed program was tested on a 10 persons with different levels of education and ages and the results show an increase in their reading speed of approximately 25% in the first month of training with noticeable enhancement in the memory as well as an increase in the ability to read for longer time without feeling nerves or boring, a nonlinear continuously increase in reading speed is assured after the first mo
... Show MoreAcquisition provisions in Islamic jurisprudence
The definition of "prostitute" and prostitution is a difficult one and a
question over which the legislators of many lands and nations differed. A
notable feature of prostitution is its epidemic increase at times of war,
revolution and armed commotion, on account of economic, social and
psychological factors generated by such conditions of mortal conflicts. Wars
invariably deprive young wives and lovers of their men folk, resulting in
financial , sexual and emotional frustrations . At no time is the natural
balance between the sexes more seriously disturbed than during wars, when
thousands of men are thrown into one sector of the country and hundreds of
towns and villages are left to women and children only. Lo
Bekhme formation, Dernir Dagh well -1 has been divided into two facies units using core
sample slides and depending on sedimentary structures and diagenetic processes .The facies
reflect the environment of the foreslope.This work proves the absence of Bekhme formation
in Dernir Dagh
Well- 1 as a tongue as reported by the Oil Exploration Company. Some species and genera of
bentonic foraminifera were identified. The age of Bekhme formation was estimated
depending on the recognized index fossils to be lower Maastrichtian.
Competencies topic in general , and Administrative competencies in specific, are considered as important subject in the contemporary administrative literature in all countries as well as in public and privet Organizations. For this reason, we have need to study those competencies in many Iraqi Organizations.
Two Organizations wer chosen for this research one of them is the Institution of taxation, and the other is the General company of Electric the data and information related to the research have been collected by desined questioner which has been given to a sample of (50) persions divided eqully between the two maintioned organizations.
The results of the study had differences
... Show More<p>The popularity, great influence and huge importance made wireless indoor localization has a unique touch, as well its wide successful on positioning and tracking systems for both human and assists also contributing to take the lead from outdoor systems in the scope of the recent research works. In this work, we will attempt to provide a survey of the existing indoor positioning solutions and attempt to classify different its techniques and systems. Five typical location predication approaches (triangulation, fingerprinting, proximity, vision analysis and trilateration) are considered here in order to analysis and provide the reader a review of the recent advances in wireless indoor localization techniques and systems to hav
... Show MoreCharacterized the Middle East has geographic, economic, and geostrategic peculiarities, but it suffers from many problems, such as disagreement over what it means as a concept, or what it represents of a geographic extension. The question is related to the ambiguity surrounding the concept of the Middle East? The purpose of its launch? As it relates to its geostrategic, economic, and geo-cultural importance? And manifestations of this importance? And to what extent he retained his value in the strategies of the major powers? Research hypotheses:
-The multiplicity of concepts for the Middle East region, with international political and Geostrategic interests.- The geostrategic value of the Middle East has made it a focal point for
... Show MoreI've been in this research preparation and diagnostic complexes mixed Kandat of Alcavaúan Alpiculan ion Althaaossianat with some metal ions has been reactive in ethanol solvent and distilled water by (1:1) and water complexes and lotions to the accounts of the metal in the complex
Background: Cross contamination of dental appliances in the dental clinics and laboratories may potentially be a health hazard to the dental team and the patient. This study aimed to evaluate bacterial contamination of acrylic complete denture as received from dental laboratory before delivery to the patient, and then to evaluate the effectiveness of disinfection with 2% chlorhexidine and Kin denture cleaner tablet. Materials and methods: 45 newly made upper complete dentures undergone biaacterial examination for contamination before delivered to the patient. Samples were examined in two stages, first after finishing and polishing; when collected from the laboratory and before inserting to the patient mouth, second; after the samples were
... Show More