Preferred Language
Articles
/
jbcd-446
Finite element stress analysis study for stresses around mandibular implant retained overdenture MIR-OD
...Show More Authors

Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 03 2016
Journal Name
International Journal Of Civil Engineering
Development of Excess Pore Water Pressure around Piles Excited by Pure Vertical Vibration
...Show More Authors

View Publication
Scopus (15)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2013
Journal Name
Iraqi Postgraduate Medical Journal
Salvage of Extruded Cochlear Implant By Interposing Pericranial Flap
...Show More Authors

BACKGROUND: Cochlear implant has become a routine procedure for management of severe sensorineural hearing loss. Cochlear implant extrusion is one of the most devastating complication of this procedure. A double layer closure of pericranial flap and scalp rotational flap has being showed to decrease the rate of late implant extrusion.OBJECTIVE:The purpose of this study is to evaluate the use of the pericranial flap as second layer coverage after cochlear implant extrusion.PATIENTS AND METHODS:Eight patients with cochlear implant extrusion in Al-Shaheed Gazi Al-Hariri hospital were operated on by using two layer closure ; the pericranial flap as salvage layer used to cover the cochlear implant and scalp rotational flap as a routine coverage,

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
Research Journal Of Pharmacy And Technology
Corrosion behavior of implant coated with different biocompatible material
...Show More Authors

View Publication
Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Tue Nov 11 2014
Journal Name
Pakistan Journal Of Biological Sciences
Effects of Local Curcumin on Oxidative Stress and Total Antioxidant Capacity in vivo Study
...Show More Authors

Publication Date
Mon Jan 01 2024
Journal Name
Lecture Notes In Electrical Engineering
A Study of the Influence of Steel Brushes in Rail Surface Magnetic Flux Leakage Detection Using Finite Elements Simulation
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jul 07 2013
Journal Name
Journal Of Educational And Psychological Researches
Vocational stresses and their relation with the level of ambition among the lecturers of the university
...Show More Authors

Vocational stresses and their relation with the level of ambition among the lecturers of the university In general , vocational stresses affect the attention and the process of focusing making individual busy with solving of his daily problems instead of his job. The vocational stresses , anxiety and tension are factors effecting the physical and psychological ability of the individual. This study aims to measure the vocational stresses among the lecturers of the university , to measure the level of ambition among them, to identify the statistical differences significant among them according to sex variable, to identify the differences significant in level of ambition among them according to sex variable and to identify the correlation r

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Engineering
Structural Systems for Modern Architecture in Iraq Analysis Study to Dr. Qahtan Al-Madfa’i’s Architecture
...Show More Authors

Dr. Qahtan Al-Madfa’i’s architecture has been characterized by a particular characteristic that may be unique and extreme at the same time, that is the use of the distinctive three-dimensional structural coverings and the exploitation of structural construction to give an extra aesthetic touch to the composition of the building, to achieve the application of his universal ideas, which he strongly believed and defended.

      In the period of the marked urban decline that the country undergoes now, which urges us toward making a comparison between the beginning of the modern Iraqi architecture and its ascending path up to its peak and the periods of its decline until it reached a very

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 28 2022
Journal Name
F1000research
In vitro apical microleakage evaluation for different endodontic sealers by spectrophotometric analysis: an observational study
...Show More Authors

Background: It has been established that several filling techniques can affect apical leakage, which is responsible for 59% of endodontic failures. The primary goal of endodontic therapy is to create a tight seal that aids in repairing the periapical tissues, prevents apical periodontitis, and shields against root canal infection. The study aims to compare the apical sealing ability of epoxy resin based sealer  (AH plus), which is an epoxy-resin-based root canal sealer, GuttaFlow 2, which is a silicone-based root canal sealer, GuttaFlow bioseal is a bioactive glass-based root canal sealer, TotalFill HiFlow bioceramic (BC) sealer is a silicate-based root canal sealer (bioceramic sealer) using a single cone techn

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 31 2006
Journal Name
Journal Of Engineering
Theoretical Simulation Of Stress-Strain Relations For Some Iraqiclays Using The Endochronic Model
...Show More Authors

Publication Date
Mon Oct 14 2019
Journal Name
Turkish Journal Of Biology
E2F6 is essential for cell viability in breast cancer cells during replication stress
...Show More Authors

Abstract: E2F6 is a member of the E2F family of transcription factors involved in regulation of a wide variety of genes through both activation and repression. E2F6 has been reported as overexpressed in breast cancers but whether or not this is important for tumor development is unclear. We first checked E2F6 expression in tumor cDNAs and the protein level in a range of breast cancer cell lines. RNA interference-mediated depletion was then used to assess the importance of E2F6 expression in cell lines with regard to cell cycle profile using fluorescence-activated cell sorting and a cell survival assay using (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). The overexpression of E2F6 was confirmed in breast tumor cDNA samp

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref