Preferred Language
Articles
/
DxdWjpIBVTCNdQwClrdm
Salvage of Extruded Cochlear Implant By Interposing Pericranial Flap
...Show More Authors

BACKGROUND: Cochlear implant has become a routine procedure for management of severe sensorineural hearing loss. Cochlear implant extrusion is one of the most devastating complication of this procedure. A double layer closure of pericranial flap and scalp rotational flap has being showed to decrease the rate of late implant extrusion.OBJECTIVE:The purpose of this study is to evaluate the use of the pericranial flap as second layer coverage after cochlear implant extrusion.PATIENTS AND METHODS:Eight patients with cochlear implant extrusion in Al-Shaheed Gazi Al-Hariri hospital were operated on by using two layer closure ; the pericranial flap as salvage layer used to cover the cochlear implant and scalp rotational flap as a routine coverage, with mean postoperative follow- up period of 6 months.RESULTS: Eight patients with late cochlear implant extrusion where operated on by using double layers closure, seven of them had no evidence of extrusion during the 6 months follow-up period. No complications were notice apart from one case who developed flap necrosis and the implant was removed later on, and another patient who had postoperative hematoma, which was surgically evacuated and the flap healed uneventfully. The results show that using pericranila flap as salvage second layer coverage in patients with cochlear implant extrusion had significant role in prevention of secondary cochlear implant extrusion. CONCLUSION: We concluded that the use of combination of pericranial flap as first layer with scalp rotational flap as secondary coverage of implant had superior result in prevention of secondary cochlear implant extrusion.

Publication Date
Tue Oct 04 2022
Journal Name
International Journal Of Dentistry
Comparison between Rolled and Nonrolled U-Shaped Flap in the Second Stage of Dental Implant Surgery: A Randomized Clinical Trial
...Show More Authors

Background. The presence of black triangles around the dental implant-supported prosthesis and the failure to construct adequate papillae around them bothers dental implantologists. Peri-implant surgical soft tissue management will improve esthetics, function, and implant survival. Aim. To compare the effects of rolled and nonrolled U-shaped flaps combined with a temporary crown in enhancing the soft tissue around dental implants. Materials and Methods. Forty patients were included in this study; all patients were operated on by the same maxillofacial surgeon at Al-Iraq specialized dental clinics from January 2019 to January 2020. Patients were divided randomly into two groups: group A: at the second stage of implant surgery, a U-sh

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Dec 25 2017
Journal Name
Biomedical And Pharmacology Journal
Evaluation of Crestal Bone Loss and Alkaline Phosphatase Level in Saliva According To Different Flap Designs in Single-Tooth Dental Implant Surgery (A Clinical Comparative Study)
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Effectiveness and safety of non-fixation method in cochlear implantation
...Show More Authors

ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 31 2024
Journal Name
Archive Of Mechanical Engineering
Computational analysis of SD7037 airfoil with plain flap
...Show More Authors

The impact of a simple trailing-edge plain flap on the aerodynamics of the SD7037 airfoil have been studied in this paper using computational fluid dynamics at Reynolds number of 3×105 across various low angles of attack and flap deflection angles. The computational model was evaluated by using Star CCM+ software with κ--ω SST turbulence and gamma transition model to solve Navier-Stokes equations. The accuracy of the computational model has been confirmed through comparison with experimental data, showing a high level of agreement at low angles of attack. The findings revealed that specific combinations of angles of attack and flap deflection angles could increase the lift-to-drag ratio by over 70% compared to baseline conditions, benefi

... Show More
Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Tympanogenic Labyrinthitis (Cochlear Deafness) due to chronic suppurative otitis media (CSOM)
...Show More Authors

Background: It has been accepted that in patients with CSOM, conductive deafness results from mechanical break-down of sound conduction ,whilist the cochlea remains unaffected.
Objectives: Our study aims to prove a sensorineural component in hearing loss in patients suffering from CSOM , which necissates early detection as it increases in severity with time.
Methods: A prospective study was done on 64 patients, all were diagnosed as having unilateral CSOM, their ages ranged from 18-40 years to exclude presbyacusis as a cause of sensorineural deafness.
These patients were divided into 4 groups according to the duration of discharge and further divided into 3 groups according to the pathology (simple perforation, granulation tissu

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 17 2023
Journal Name
Karbala International Journal Of Modern Science
Biofunctionalization of polyetheretherketone implant material by bone-forming peptide-2 immobilization
...Show More Authors

Polyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (4)
Scopus Crossref
Publication Date
Mon Dec 05 2022
Journal Name
F1000research
Enhancement of surface properties of polyetheretherketone implant material by fractional laser texturing
...Show More Authors

Background: Polyetheretherketone (PEEK) is a promising implant material due to its superior biomechanical strength. However, due to its hydrophobic nature and lack of cellular adhesion properties, it has poor integration with bone tissue. Methods: A fractional CO2 laser was used with various parameters for surface texturing of PEEK substrate to enhance its surface properties. An optical microscope and field-emission scanning electron microscope (FESEM) were used to examine the surface morphology of untextured and laser-textured samples. Energy dispersive X-ray spectroscopy (EDX) was performed to determine the effect of the laser on the microstructure of PEEK. Surface microroughness, atomic force microscopy (AFM), and wettability were invest

... Show More
View Publication Preview PDF
Crossref (3)
Scopus Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Neuroquantology
Evaluation of using of square flap in treatment of Postburn Contracture
...Show More Authors

Background: One of the most common problems that encountered is postburn contracture which has both functional and aesthetic impact on the patients. Various surgical methods had being proposed to treat such problem. Aim: To evaluate the effectiveness of square flap in management of postburn contracture in several part of the body. Patients and methods: From April 2019 to June 2020 a total number of 20 patients who had postburn contracture in various parts of their body were subjected to scar contracture release using square flap. The follow up period was ranging between 6 months to 12 months. Results: All of our patients had achieved complete release of their band with maximum postoperative motion together with accepted aesthetic outcome. A

... Show More
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Corrosion protection of pure titanium implant by electrochemical deposition of hydroxyapatite post-anodizing
...Show More Authors

In this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul

... Show More
View Publication Preview PDF
Scopus (12)
Scopus
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF