Background: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hospital of specialized surgery, these patient were wearing a mandibular implant retained over denture for two years these patients having MIR-OD with Bar-clip, ball-cup and O- ring attachments. Preparative radiography was obtained for this patient from the center .these radiograph was taken to the patient at time of insertion. The second radiograph image was taken to the patient after two years of function with prosthesis. .the scanned images were transfer to special folder in a computer then analysis of bone loss done using Dimax software. After that an accurate calibrations of crestal bone measurement were analyzed for both groups of Radiography. Results it was appeared that the amount of bone loss in ball and bar designs (of mandibular Implant retained overdenture) were within the criteria of successful rate of bone loss during the period of examination, and there was statistically significant difference between both types of anchorage system. Conclusions The amount of bone loss was 0.1 mm after two years follow up, and it was within the acceptable limits of bone lose. A significant difference appeared between both designs of MIR-OD, Ball and bar designs.
Abstract Asthma is a complex disease defined by chronic airway inflammation and airflow limitation causing variable respiratory symptoms which include shortness of breath (SOB), wheezing, chest tightness and cough. Asthma guidelines advocate adding a second long acting bronchodilator to medium doses of inhaled corticosteroids (ICS) rather using high doses of ICS alone to control moderate to severe persistent asthma. The aim of this study was to evaluate the clinical outcomes of three medication regimens indicated for Iraqi patients suffering from persistent asthma. This study was interventional randomized clinical study conducted on a sample of adult Iraqi asthmatic patients in Baghdad City. The study com
... Show MoreBackground: Alveolar ridge expansion is proposed when the alveolar crest thickness is ≤5 mm. The screw expansion technique has been utilized for many years to expand narrow alveolar ridges. Recently, the osseodensification technique has been suggested as a reliable technique to expand narrow alveolar ridges with effective width gain and as little surgical operating time as possible. The current study aimed to compare osseodensification and screw expansion in terms of clinical width gain and operating time. Materials and methods: Forty implant osteotomies were performed in deficient horizontal alveolar ridges (3–5 mm). A total of 19 patients aged 21–59 years were randomized into two groups: the screw expansion group, which invo
... Show MoreAbstract
Asthma is a complex disease defined by chronic airway inflammation and airflow limitation causing variable respiratory symptoms which include shortness of breath (SOB), wheezing, chest tightness and cough. Asthma guidelines advocate adding a second long acting bronchodilator to medium doses of inhaled corticosteroids (ICS) rather using high doses of ICS alone to control moderate to severe persistent asthma. The aim of this study was to evaluate the clinical outcomes of three medication regimens indicated for Iraqi patients suffering from persistent asthma.
This study was interventional randomized clinical study conducted on a sample of adult Iraqi asthm
... Show MoreObjective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an
... Show MoreBackground: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was conside
... Show MoreBackground: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)
... Show MoreAim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a
... Show MoreEvaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars, Hussain A Taher*, Salwan Y Bede
Social factors may affect the available sources of toxic substances and causes of poisoning, and these factors may change over time. Additionally, understanding the characteristics of poisoning cases is important for treating such patients. Therefore, the present study investigated the characteristics of poisoning cases in Baghdad Poisoning Consultation Center (PCC) and Forensic Medicine Institute (FMI). Data on all poisoning cases reported in PCC and FMI during 2013 were retrospectively obtained from medical records. Total of 1131 reports of poisoning cases (1082 from PCC and 49 from FMI) were analyzed according to age, sex, geographical distribution and causes of poisoning according to the type and class of poisoning agent. The results
... Show More