Background: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hospital of specialized surgery, these patient were wearing a mandibular implant retained over denture for two years these patients having MIR-OD with Bar-clip, ball-cup and O- ring attachments. Preparative radiography was obtained for this patient from the center .these radiograph was taken to the patient at time of insertion. The second radiograph image was taken to the patient after two years of function with prosthesis. .the scanned images were transfer to special folder in a computer then analysis of bone loss done using Dimax software. After that an accurate calibrations of crestal bone measurement were analyzed for both groups of Radiography. Results it was appeared that the amount of bone loss in ball and bar designs (of mandibular Implant retained overdenture) were within the criteria of successful rate of bone loss during the period of examination, and there was statistically significant difference between both types of anchorage system. Conclusions The amount of bone loss was 0.1 mm after two years follow up, and it was within the acceptable limits of bone lose. A significant difference appeared between both designs of MIR-OD, Ball and bar designs.
Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s
... Show MoreThe spread of novel coronavirus disease (COVID-19) has resulted in chaos around the globe. The infected cases are still increasing, with many countries still showing a trend of growing daily cases. To forecast the trend of active cases, a mathematical model, namely the SIR model was used, to visualize the spread of COVID-19. For this article, the forecast of the spread of the virus in Malaysia has been made, assuming that all Malaysian will eventually be susceptible. With no vaccine and antiviral drug currently developed, the visualization of how the peak of infection (namely flattening the curve) can be reduced to minimize the effect of COVID-19 disease. For Malaysians, let’s ensure to follow the rules and obey the SOP to lower the
Breast cancer constitutes about one fourth of the registered cancer cases among the Iraqi population (1)
and it is the leading cause of death among Iraqi women (2)
. Each year more women are exposed to the vicious
ramifications of this disease which include death if left unmanaged or the negative sequels that they would
experience, cosmetically and psychologically, after exposure to radical mastectomy.
The World Health Organization (WHO) documented that early detection and screening, when coped
with adequate therapy, could offer a reduction in breast cancer mortality; displaying that the low survival rates
in less developed countries, including Iraq, is mainly attributed to the lack of early detection programs couple
Background: Determination of sex from an unknown human bone is an important role in forensic and anthropology field. The mandible is the largest and hardest facial bone, that commonly resist postmortem damage and forms an important source of information about sexual dimorphism. Mandibular ramus can be used to differentiate between sexes and it also expresses strong univariate sexual dimorphism. This study was undertaken to assess the usefulness of mandibular ramus as an aid in sex differentiation using CT scanning among Iraqi population. Materials and methods: 3D reconstructed computed tomography scanning of 140 Iraqi Arab subjects, (7 0 males and 70 females) were analyzed with their age range from 20-60 years old. The linear measurements w
... Show MoreKE Sharquie, AA Noaimi, AA Zeena, IOSR J Dent Med Sci, 2015 - Cited by 5
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show MoreBackground: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.
Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in Eye Specialty Private Hospital, Baghdad, Iraq.
Type of the Study: a prospective non randomize intervention study.
Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter
... Show More