Background: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hospital of specialized surgery, these patient were wearing a mandibular implant retained over denture for two years these patients having MIR-OD with Bar-clip, ball-cup and O- ring attachments. Preparative radiography was obtained for this patient from the center .these radiograph was taken to the patient at time of insertion. The second radiograph image was taken to the patient after two years of function with prosthesis. .the scanned images were transfer to special folder in a computer then analysis of bone loss done using Dimax software. After that an accurate calibrations of crestal bone measurement were analyzed for both groups of Radiography. Results it was appeared that the amount of bone loss in ball and bar designs (of mandibular Implant retained overdenture) were within the criteria of successful rate of bone loss during the period of examination, and there was statistically significant difference between both types of anchorage system. Conclusions The amount of bone loss was 0.1 mm after two years follow up, and it was within the acceptable limits of bone lose. A significant difference appeared between both designs of MIR-OD, Ball and bar designs.
BACKGROUND: Cochlear implant has become a routine procedure for management of severe sensorineural hearing loss. Cochlear implant extrusion is one of the most devastating complication of this procedure. A double layer closure of pericranial flap and scalp rotational flap has being showed to decrease the rate of late implant extrusion.OBJECTIVE:The purpose of this study is to evaluate the use of the pericranial flap as second layer coverage after cochlear implant extrusion.PATIENTS AND METHODS:Eight patients with cochlear implant extrusion in Al-Shaheed Gazi Al-Hariri hospital were operated on by using two layer closure ; the pericranial flap as salvage layer used to cover the cochlear implant and scalp rotational flap as a routine coverage,
... Show MoreThe development that solar energy will have in the next years needs a reliable estimation of available solar energy resources. Several empirical models have been developed to calculate global solar radiation using various parameters such as extraterrestrial radiation, sunshine hours, albedo, maximum temperature, mean temperature, soil temperature, relative humidity, cloudiness, evaporation, total perceptible water, number of rainy days, and altitude and latitude. In present work i) First part has been calculated solar radiation from the daily values of the hours of sun duration using Angstrom model over the Iraq for at July 2017. The second part has been mapping the distribution of so
Abstract: Choosing suitable artificial teeth for partially edentulous patients and arranging these teeth in a way to look natural is difficult. An important factor in dentures construction is the mesiodistal width of anterior teeth, because a denture would not appearance natural if artificial teeth are of incorrect size. While for a successful orthodontic treatment, mesiodeistal width of teeth is important for space analysis and for establishing proper occlusion. The aim of this study is to determine the correlation between the average mesiodistal width of anterior and posterior teeth in male and female Iraqi population. 40 Iraqi subjects with normal occlusion participated in this study. Mesiodistal measurement of all teeth was carried out
... Show MoreMany cases of gravitational bullets are reported in developed and non-developed countries. However, few papers highlighted these cases in the literature. In our study, we present two cases of gravitational bullets that have an unusual coincidence in the injury characteristics through their ages, and gender, the site of the inlet.
In the literature, several correlations have been proposed for hold-up prediction in rotating disk contactor. However,
these correlations fail to predict hold-up over wide range of conditions. Based on a databank of around 611
measurements collected from the open literature, a correlation for hold up was derived using Artificial Neiral Network
(ANN) modeling. The dispersed phase hold up was found to be a function of six parameters: N, vc , vd , Dr , c d m / m ,
s . Statistical analysis showed that the proposed correlation has an Average Absolute Relative Error (AARE) of 6.52%
and Standard Deviation (SD) 9.21%. A comparison with selected correlations in the literature showed that the
developed ANN correlation noticeably
Background: Piezosurgery improved the split approach by making it safer, easier, and less prone to complications when treating extremely atrophic crests. Densah drills, with their unique design, expand the ridge by densifying bone in a reverse, non-cutting mode. Objective: To assess the effectiveness of sagittal piezosurgery, which involves cutting bone to the full implant depth and then expanding it using osseodensification drills. We use this technique to expand narrow alveolar bones and simultaneously place dental implants in the maxillary and mandibular arches. Methods: Fourteen patients received 31 dental implants. The maxillary arch received 19, and the mandible received 12 dental implants. This study will include patients who
... Show MoreBackground: Numerous methods have been described for achievement of Intermaxillary fixation in the treatment of fractures of facial skeleton. Conventional methods like Erich arch bars and eyelet wires are currently the most common methods for achieving intermaxillary fixation (IMF), however, they have their own disadvantages. Since 1989, IMF using intraoral self-tapping IMF screws has been introduced for treatment of mandibular fractures. The aim of this study was to evaluate the efficacy, advantages, disadvantages and potential complications associated with using of self-tapping IMF screws in the treatment of mandibular fractures. Material and Methods: Twenty patients with favorable mandibular fractures, attended to Oral and Maxillofacial
... Show MoreAim: To evaluate the wettability and microhardness of Zirconium (ZrO2) dental material when coated with different concentrations of Faujasite. Materials and methods: 30 circular disks produced from ZrO2, then each group is classified into 10 control groups, 10 coated groups with 3% Faujasite, and 10 coated groups with 7% faujasite by electro-spun tool to study variable properties in hardness and water contact angle of implant materials. Results: This study stated the high hardness in 7% of faujasite concentration for ZrO2, in addition, the contact angle decreased gradually until reach 0 ᵒ in 7% concentration of faujasite with ZrO2 Conclusion: Water contact angle (WCA) declined till disappeared in (7% wt.) of faujasite coated with the Z
... Show MoreThis study compared the clinicopathological, immunohistochemical characteristics and Epstein-Barr virus (EBV) detection of Burkitt's lymphoma (BL) in the abdomen and jaw of Iraqi patients. A cohort/retrospective study was carried out between August and September 2024 using 25 tissue blocks (14 gnathic and 11 abdominal BL) from the Oral and Maxillofacial Laboratory, University of Baghdad, College of Dentistry, and the National Centre for Educational Laboratories. The sections were stained with haematoxylin and eosin (H&E), while CD10, CD20, Bcl-2, BCl-6, C-Myc and Ki-67 markers were used for diagnosis. The DNA detection of the EBV was performed by polymerase chain reaction (PCR). The tumours showed 22 classical and 3 atypical histologi
... Show More