Preferred Language
Articles
/
jbcd-3144
Effects of various analgesics on pain perception and rate of tooth movement: a randomized controlled clinical study
...Show More Authors

Background: Pain is one of the most reported side effects of orthodontic treatment despite the advanced technology in orthodontics. Many analgesics have been introduced to control orthodontic pain including acetaminophen and selective and nonselective nonsteroidal anti-inflammatory drugs. The great concern about these drugs is their adverse effect on rate of teeth movement. Aims: The purpose of this study was to evaluate and compare the effect of acetaminophen, ibuprofen and etoricoxib on pain perception and their influence on the rate of teeth movement during leveling and alignment stage. Methods: Forty patients were evenly and randomly distributed in a blinded way to one of four groups: placebo (starch capsules), acetaminophen 500mg thrice daily, ibuprofen 400mg thrice daily, and etoricoxib 60mg once daily. The drugs were given one hour before bonding and archwire placement and continued for three days. A visual analogue scale was used to express pain levels before and after archwire placement, on the first, second, third, and seventh day. Little’s irregularity index was measured before bonding and at every activation visit until the end of the alignment and leveling stage. Results: All three drugs showed a lower pain level than placebo at the bonding and first activation visits. Etoricoxib showed the least pain level among other drugs followed by ibuprofen. No statistically significant differences were found between the drug groups and the placebo at the second and third activation visits. No statistically significant differences were detected between the 4 experimental groups concerning the rate of teeth movement. Conclusions: The three drugs were only effective in controlling pain during the first two visits of orthodontic treatment; and etoricoxib 60mg/day was the best. All three drugs had no influence on rate of teeth movement when used in their least recommended dose.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effects of Sodium Chloride and Sodium Sulphate Solutions on the Output of the Electrochemical Machining
...Show More Authors

Electrochemical Machining is a term given to one of nontraditional machining that uses a chemical reaction associated with electric current to remove the material. The process is depending on the principle of anodic dissolution theory for evaluating material removal during electrochemical process. In this study, the electrochemical machining was used to remove 1 mm from the length of the a workpiece (stainless steel 316 H) by immersing it in to electrolyte (10, 20 and 30 g) of NaCl and Na2SO4 to every (1 litter of filtered water).  The tool used was made from copper. Gap size between the workpiece and electrode is (0.5) mm. This study focuses on the effect of the changing the type and concentration of electroly

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Effects of Anthracene Doping Ratio and UV Irradiation Time on Photo-Fries Rearrangement of Polycarbonate
...Show More Authors

Thin films of pure polycarbonate (PC) with anthracene doping PC films for different doping ratios (10, 20, 30, 40, 50 and 60 ml) were prepared by using a casting method. The influence of anthracene doping ratio on photo-fries rearrangement of polycarbonate was systematic investigated. Furthermore, pure PC and anthracene doping PC films were irradiated via UV light at a wavelength (254 nm) for different periods (5, 240, 288, and 360 hrs). The photo-fries rearrangement occurring in pure PC and anthracene doping PC films were monitored using UV and FTIR spectroscopies. The photo-fries rearrangement leads to scission the carbonate linkage and formation phenylsalicylate and dihydroxybenzophenes. The result of the UV spectrum confirms disappea

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effects of Enamel Protective Agents on Shear Bond Strength After Rebonding of Stainless Steel Orthodontic Bracket (An in Vitro Study)
...Show More Authors

ABSTRACT Background: Bracket rebonding is a common problem in orthodontics which may result in many drawbacks. The aims of this study were to evaluate the effects of application of two enamel protective agents “Icon” and “ProSeal” on shear bond strength before and after rebonding of stainless steel orthodontic brackets using conventional orthodontic adhesive and to assess the site of bond failure. Materials and methods: Fifty sound extracted human upper first premolar teeth were selected and randomly divided into two equal groups; the first time bonding and the rebonding groups (n=30). Each group was subdivided into control, Icon and ProSeal subgroups. The enamel protective agents were applied after etching (precondi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Insertion Rate on The Adaptability of Gutta-Percha and The Apical Extrusion of Thermoplasticized Gutta Percha Obturation Techniques.
...Show More Authors

Background: In the Thermafil as a root canal obturation, system little is known about the effect that varying rates of insertion have on the adaptability of thermoplasticized GP and the amount of apical extrusion. Materials and methods: thirty simulated root canals were obturated with thermafil obturators and Apexit Plus sealer at three different insertion rates. The obturated canals were sectioned at three different levels, the sealer average film thickness for each section was calculated and the amount of apical extrusion for each canal was conducted. Results: the higher adaptability was seen with the faster insertion rate while the slower insertion rate showed fewer tendencies to cause apical extrusion. Conclusions: the intermediate i

... Show More
View Publication
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
The Turkish Journal Of Endocrinology And Metabolism
Cell-free DNA as a Clinical Indicator in Maternal Blood
...Show More Authors

As many expensive and invasive procedures are used for the diagnosis or follow-up of clinical conditions, the measurement of cell-free DNA is a promising, noninvasive method, which considers using blood, follicular fluid, or seminal fluid. This method is used to determine chromosomal abnormalities, genetic disorders, and indicators of some diseases such as polycystic ovary syndrome, pre-eclampsia, and some malignancies. Cell-free DNA, which are DNA fragments outside the nucleus, originates from an apoptotic process. However, to be used as a marker for the previously mentioned diseases is still under investigation. We discuss some aspects of using cell-free DNA measurements as an indicator or marker for pathological conditions.

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Migration Letters
Organizational Machiavellianism and Its Impact on Employees’ Passion: A Field Study on a Sample of Electronic Payment Companies in Iraq
...Show More Authors

View Publication
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Characterization of Poly (D,L-Lactide-Co-Glycolide) Microspheres for Controlled Release of KSL Peptide
...Show More Authors

The purpose of this research was to prepare, characterize, and evaluate the new antimicrobial peptide  KSL peptide encapsulated in poly(D,L-lactide-co-glycolide) (PLGA)composite microspheres. KSL was loaded in poly(acryloyl hydroxyethyl) starch (acHES) micropar-ticles, and then the peptide-containing microparticles were encapsulated in the PLGA matrix by a solvent extraction /evaporation method.

 KSL-loaded PLGA microspheres were also prepared without the starch hydrogel microparticle microspheres for comparison study. KSL peptide microspheres were characterized for drug content, surface morphology, microspheres size determination, polymers stability , in vitro microspheres degradation and in vitro release. KSL peptide

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The prevalence of Candida spp. in the saliva of controlled and uncontrolled diabetes mellitus type II patients
...Show More Authors

Background: Diabetes mellitus type 2 has been known for many years as the most common endocrine metabolic disorder that affect the oral cavity and cause many oral diseases including candidiasis. In this study, the incidence of Candida spp. in the saliva of controlled and uncontrolled diabetic patients were determined and compared with non diabetic group. Material and method: The sample consists of 200 subjects: 100 diabetic patients [57 (28.5%) uncontrolled diabetes, 43 (21.5%) controlled diabetes] and 100 (50%) non diabetic groups. Saliva samples was obtained from the subjects and cultured on selective media using appropriate microbiological method to observe the presence of Candida spp. Results: The results revealed a significant associat

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Comparative study of the renoprotective effects of captopril and aminophylline against cainst cisplatin – induced nephrotoxicty in rats
...Show More Authors

Background: Cisplatin is one of the most
commonly used anti-cancer drugs , but its
clinical use was limited by its nephrotoxicity .
Methods: In this study we try to investigate the
renoprotective effect of captopril and
aminophylline against cisplatin induced
nephrotoxicity .For this purpose a 36 Sprague
Dawley rats was divided randomly to 6 groups ,
each group consist of 6 rats. The first group
given normal saline and act as control group,
while the other 5 groups given cisplatin ( 7.5
mg/kg ) , captopril ( 60 mg/kg ) , aminophylline
( 24 mg/kg ) , captopril with cisplatin and
aminophylline with cisplatin respectively. All
drugs are given as single dose through
intraperitonial route. After 6

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Physiological and Hormonal Effects of Titanium Dioxide Nanoparticles on Thyroid Function and the Impact on Bodyweight in Male Rats
...Show More Authors

Fifty-four Sprague-Dawley albino adult male rats were classified into three main groups each of 18 rats treated for a particular duration (1,2, and 4) weeks respectively. Each group was subdivided into three subgroups each of six rats treated as follows; group (1) serve as normal control, group (2, and 3) intra-peritoneal treated with TiO2NPs (50,200) mg/kg respectively, body *weight of all rats was measured before and after the experiment, then rats were dissected at the end of each experiment and the weights of the thyroid was measured. The result showed a highly significant decrease (p<0.01) in thyroid gland weight, a highly significant increase (p<0.01) in body weights and TSH, while a highly significant decrease (p&

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Crossref