Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant stability changes throughout the study period and its correlation with the recipient jaw and the DI dimensions were evaluated. Results: There was a significant difference in ISQ values throughout the study. DI stability in the maxilla was significantly higher than that in mandible for the ISQ0, with no significant effect for the rest time points. The effect of implant diameter was significant with DI of 4.1mm diameter being more stable. While for the length, there was no significant difference regarding its effect on ISQ values through-out the study period. Conclusions: DI inserted in the maxilla demonstrated better primary stability with no effect of recipient jaw on secondary stability and after functional loading, also DI with wider diameter had better stability throughout the study whereas DI length showed no significant effect on stability
In this work, strains and dynamic crack growth were studied and analyzed in thin flat plate with a surface crack at the center, subjected to cycling low velocity impact loading for two types of aluminum plates (2024, 6061). Experimental and numerical methods were implemented to achieve this research. Numerical analysis using program (ANSYS11-APDL) based on finite element method used to analysis the strains with respect to time at crack tip and then find the velocity of the crack growth under cycling impact loading. In the experimental work, a rig was designed and manufactured to applying the cycling impact loading on the cracked specimens. The grid points was screened in front of the crack tip to measure the elastic-plas
... Show Moreهدفت هذه الد ا رسة لاختبار تاثير بعض ظروف النمو على الفاعلية التثبيطية لبكتيريا Lactobacillus delbrueckii و L.fermentum على نمو بكتيريا E.coli وقد دلت نتائج د ا رسة اختبار الفاعلية التثبيطية
للعزلتان البكتيريتان Lactobacillus delbrueckii L.fermentum , ضد العزلة البكترية E.coli المستخدمة في هذه الد ا رسة عند الت ا ركيز المختلفة 100,90,70,50) ( % بان عالق العزلتان البكتيريتان
Lactobacillus delbrueckii و L.fermentum عند التركيز % 100 اعطى اعلى فاعلية تثبيطية ضد
بكتريا E.coli
Background/: Buccal tubes are orthodontic attachments used on the posterior teeth instead of bands, so it is important to focus on the effect of their properties on orthodontic treatment. The aims of the present in vitro study are to evaluate and compare the buccal tube front and back openings dimensions and the torsional play angle of six different brands. Materials and Methods: The samples consisted of Single bondable, non-convertible first molar buccal tubes from six brands supplied from six companies (Dentaurum, Forestadent, Ormco, 3M, American Orthodontic, A-Star). Regarding tube opening dimension, ten buccal tubes of each brand were examined by an optical microscope. Each tube was fixed during examination using synthetic mud and orie
... Show MoreThe objective of the present study is to determine the effect of Kaolin as a fuel oil additive to minimize the fireside corrosion of superheater boiler tubes of ASTM designation (A213-T22) by increasing the melting point of the formed slag on the outside tubes surface, through the formation of new compounds with protective properties to the metal surface. The study included measuring corrosion rates at different temperatures with and without additive use with various periods of time, through crucible test method and weight loss technique.
A mathematical model represents the relation between corrosion rate and the studied variables, is obtained using statistical regression analysis. Using this model,
... Show MoreThe objective of this research is to study the possibility of reducing the reflectivity of the front surface of a silicon cell (Si / Si) by using a theoretical design for a single-layer Antireflection Coatings with a thickness of one quarter of the design wavelength. Then, Mathematical programs in MATLAB (10) were designed to study the quantitative efficiency of the cell as a function of the change in the particle size of the coating within the range (400 - 700 nm) wavelength of the visible state of the vertical and oblique state at the (45°) angle. (Ge) was used as an anti-reflective material. It was found that the highest quantitative efficiency was (96.9004%) at design wavelength (λ0= 550 nm)
... Show MoreObjectives: The purpose of this in vitro study was to compare the effect of adding a poloxamer surfactant to the irrigant solutions on its cleaning efficiency. Design: In this study the roots of extracted permanent premolar teeth were used and evaluated by using Scanning Electronic Microscopy (SEM). Materials and Method: 72 human single tooth of permanent premolar (8 for each group) were used in this in vitro study. Roots after sectioning at cervical area to get 15 mm were embedded in a plastic container filled with impression silicon, then instrumented with ProTaper rotary instruments till size F4. Each group (8 root) were irrigated with one of the nine solutions used in study: three concentrations of NaOH [5% (A1), 2.5%(A2), 0.5%(A3)], th
... Show MoreIn the present study, the structural properties which included the X-rays diffraction, and DSC, the mechanical properties, which include tensile test, threepoint bending test (Bending Test), hardness test and thermal conductivity of the polymers reinforced with calcite (PVC/CaCO3) at different temperature (25-40-80-
120-160-200-220) °C. The research results showed that the XC degree of X-ray diffraction decreased at high temperatures (220 ˚C), while the inter-polymerized polymer (PVC / CaCO3) increased at high temperatures. The DSC test results showed that the degree of crystallinity (XC) decreases at high temperatures (220 ˚C). The mechanical test results, their values were found to decrease at (
In this study a polymeric composite material was prepared by hand
lay-up technique from epoxy resin as a matrix and magnesium oxide
(MgO) as a reinforcement with different weight fraction (5,10,15,
and 20)% to resin. Then the prepared samples were immersed under
normal condition in H2So4(1 M) solution, for periods ranging up to
10 weeks. The result revealed that the diffusion coefficient
decreasing as the concentration of MgO increase. Also we studied
Hardness for the prepared samples before and after immersion. The
result revealed that the hardness values increase as the concentration
of MgO increase, while the hardness for the samples after immersion
in H2SO4 dec
The objective of the investigation was to analyze the structure and administration of the political system in Iraq (post-ISIS). After 2003, the Iraqi political system suffered the fundamental problem of its failure to achieve the political and social inclusion that characterizes democratic systems, to guarantee the establishment of a "state for all", while respecting differences. Political representation has moved from the system of sectarian ethnic components, under the title of consensual democracy, to the representation of leaders and the realization of their interests and the interests of their parties at the expense of the groups that claim to represent them, which complicates the problem. In this sense, the new political syste
... Show MoreIn this research thin films of (CdTe) have been prepared as pure and doped by Zn
with different ratios (1,2,3,4,5)% at thickness (400+25)nm with deposition rate (2±0.1)nm,
deposited on glass substrate at R.T. by using thermal evaporation in vacuum . All samples
were annealed at temperature (523,573,623,673)K at 1h.
The structural prop erties of all prepared thin films, doped and undoped have been
studied by using XRD. The analysis reveals that the structures of the films were
polycrystalline and typed cubic with a preferred orientation along (111) plane for the
undoped films with (2,3)% of zinc , and shifting (2ÆŸ) for doped films . The annealing films
at temperature 573 K and Zn:3% show decreasing in