Background: Nowadays there is an increasing of the emphasis on aesthetic, dentist have been concerned about providing aesthetics and functional removable partial dentures to their patients and this was make the mission more difficult because of the goal now is achieving optimal aesthetic of the denture - while maintaining retentive, stable, and conservative to the health of supporting tooth and supporting tissue. The traditional use of metal clasp like cobalt-chromium, gold, stainless-steel and titanium hampers esthetics because of its obvious display conflicts with patient’s prosthetic confidentiality. Acetal resin (poly oxy methylene) may be used as alternative denture clasp material. This material was promoted primarily on the basis of its superior esthetic. Material and method: In this study, Acetal resin of Flexite and co-cr alloy of Wirocast companies were used. Four metal models of two premolars and two molars were surveyed to have 0.25mm and 0.5mm undercut depth for each one of the materials. eighty clasps were prepared and tested by testing machine to measure the load required to dislodge Acetal and co-cr clasps of 2mm. thickness (for premolar and molar). Tensile test were utilized for both Acetal resin and co-cr. tensile values will be used in special formula to calculate the amount of deflection. Results: The results of this study revealed that Acetal resin clasp of molar with 0.5mm undercut depth have the higher retentive force, and premolar with 0.25 mm undercut depth have the lowest retentive force as compared to co-cr. Also Acetal had lower values of the tensile strength as compared to co-cr alloy but it had higher deflection value than co-cr and it can withstand higher deflections than those of co-cr before having permanent deformation or fracture Conclusions: Acetal resin can be used with limitation as an alternative to co-cr alloy clasps in removable partial dentures.
new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-
... Show MorePhase change material (PCM) is considered as one of the most effective thermal energy storage (TES) systems to balance energy supply and demand. A key challenge in designing efficient PCM-based TES systems lies in the enhancement of heat transmission during phase transition. This study numerically examines the privilege of employing twisted-fin arrays inside a shell-and-tube latent heat storage unit to improve the solidification performance. The presence of twisted fins contributes to the dominating role of heat conduction by their curved shapes, which restricts the role of natural convection but largely aids the overall heat-transfer process during solidification. The heat-discharge
This paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used. Experimental results shows LPG-PCA method
... Show MoreAverage interstellar extinction curves for Galaxy and Large Magellanic Cloud (LMC) over the range of wavelengths (1100 A0 – 3200 A0) were obtained from observations via IUE satellite. The two extinctions of our galaxy and LMC are normalized to Av=0 and E (B-V)=1, to meat standard criteria. It is found that the differences between the two extinction curves appeared obviously at the middle and far ultraviolet regions due to the presence of different populations of small grains, which have very little contribution at longer wavelengths. Using new IUE-Reduction techniques lead to more accurate result.
This paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used.
Experimental results shows LPG-
... Show MoreBackground: The ideal maxillofacial prosthesis should have fine and thin boundaries that bindwith the surrounding facial structures and possess high tear strength.This study aims to determinethe best percentages of nanofiller (TiO2) and intrinsic pigment (silicone functional intrinsic) thatcould be mixed in as additives to improve the tear strength of Cosmesil M511 andVST50F siliconeelastomers with the least effect on their hardness.Materials and Methods: In this in vitro experimental study, a total of 80 samples, 40 for eachelastomer, were fabricated. Each elastomer sample was split into two equal groups to test for tearstrength and Shore A hardness. Each group consisted of 20 samples, including 10 control sampleswithout additives and 10 e
... Show MoreBackground: Thyroid surgery is most common endocrine surgery in general surgical practice. Objectives: the aim of this work is to evaluate the feasibility, benefits and outcomes of open mini-incision thyroidectomy and compared the results with that of conventional thyroidectomy. The comparison between the two groups was in term of incision length, amount of blood loss, time of operation, postoperative pain, hospital stay and the cosmetic outcomes.Type of the study: this is a single-blinded randomized controlled studyMethods: This study compared the advantages and outcomes of 22 patients subjected to mini-incision thyroidectomy (Group A) with the equal numbers of patients subjected to conventional thyroidectomy (Group B).Results: the oper
... Show MoreIn this paper, we employ the maximum likelihood estimator in addition to the shrinkage estimation procedure to estimate the system reliability (
<p><strong>Objective: </strong>The aim of our study was to compare between flavonoids and phenolic acids contents of leaves and fruits of <em>Melia azedarach</em> since no phytochemical investigation had done previously in Iraq.</p><p><strong>Methods: </strong>The leaves and fruits of <em>Melia azedarach </em>were extracted by soxhlet using 80% ethanol then the dried extract was suspended in water and fractionated using petroleum ether, chloroform, ethyl acetate, and n-butanol. The n-butanol fraction was hydrolyzed by acid and partitioned with ethyl acetate. The different fractions containing flavonoids and phenolic acids were analyzed by HPLC and HPTLC.</p><
... Show MoreThe goal beyond this Research is to review methods that used to estimate Logistic distribution parameters. An exact estimators method which is the Moment method, compared with other approximate estimators obtained essentially from White approach such as: OLS, Ridge, and Adjusted Ridge as a suggested one to be applied with this distribution. The Results of all those methods are based on Simulation experiment, with different models and variety of sample sizes. The comparison had been made with respect to two criteria: Mean Square Error (MSE) and Mean Absolute Percentage Error (MAPE).