Preferred Language
Articles
/
jbcd-291
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were scanned using Computed Tomography (Initial scan). After canal preparation with ProTaper (group A), BioRaCe (group B), and Self Adjusting File (group C) the roots were rescanned (Final scan), the degree of canal transportation and centering ability were assessed at apical (4 mm), middle (6 mm), coronal (9 mm) sections using computed tomography. The collected data were statistically analyzed using ANOVA and Least Significant Difference tests. Results: There were no statistically significant differences among the groups at level 4 mm and level 9 mm (P ? 0.05). However, at level 6 mm there was a highly significant difference between (A) and (B) groups (P ? 0.01) and there was a significant difference between (A) and (C) groups (P ? 0.05). There were no statistically significant differences among different levels of (A) and (C) groups (P ? 0.05), while (B) group showed a highly significant difference between 4 mm and 9 mm levels and between 6 mm and 9 mm levels (P ? 0.01). Regarding canal centering ability, there was no statistically significant difference among the three groups at different levels (P ? 0.05)., while (B) group showed a significant difference between 4 mm and 9 mm levels (P ? 0.05), and a very highly significant difference between 6 mm and 9 mm levels (P ? 0.001). Conclusion: The study demonstrated that canal preparation with the three designs of Ni-Ti instruments produced canal transportation. Self Adjusting File group showed less canal transportation than ProTaper group. There was a comparable value of canal centering ability among different levels in each group except in BioRaCe group.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 01 2012
Journal Name
Journal Of Endodontics
Synthesis and Preliminary Evaluation of a Polyolefin-based Core for Carrier-based Root Canal Obturation
...Show More Authors

Introduction: Carrier-based gutta-percha is an effective method of root canal obturation creating a 3-dimensional filling; however, retrieval of the plastic carrier is relatively difficult, particularly with smaller sizes. The purpose of this study was to develop composite carriers consisting of polyethylene (PE), hydroxyapatite (HA), and strontium oxide (SrO) for carrier-based root canal obturation. Methods: Composite fibers of HA, PE, and SrO were fabricated in the shape of a carrier for delivering gutta-percha (GP) using a melt-extrusion process. The fibers were characterized using infrared spectroscopy and the thermal properties determined using differential scanning calorimetry. The elastic modulus and tensile strength tests were dete

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Study of The Amount of Apically Extrusion Of Debris During Root Canal Preparation Using Wave Oneâ„¢, Trushape 3Dâ„¢, Hyflexâ„¢ CM and One Shapeâ„¢ Instrumentation Systems (An In Vitro Study)
...Show More Authors

Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of mandibular third molar position by using computed tomography and reconstructed lateral radiograph
...Show More Authors

Background: Consideration of mandibular third molar is important from orthodontic perspective due to several factors such as, lower anterior arch crowding, relapse in lower anterior region, interference with uprighting of mandibular first and second molars during anchorage preparation and molar distalization. The aims of this study were to assess of gender differences in the mandibular third molar position and compare and evaluate whether there is any differences in the results provided by CT scan and lateral reconstructed radiograph. Materials and Methods: The sample of present study consisted of 39 patients (18 males and 21 females) with age range 11-15 years. CT images for patients who were attending at Al Suwayra General Hospital/the C

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 02 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
A Comparative Evaluation of Gutta-Percha and Sealer Removal of Rotary Niti File Retreatment Systems
...Show More Authors

Scopus
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
A Comparative Evaluation of Gutta-Percha and Sealer Removal of Rotary Niti File Retreatment Systems
...Show More Authors

Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 21 2021
Journal Name
Contemporary Clinical Dentistry
Assessment of maxillary incisors' angulation and position in different types of malocclusions using cone-beam computed tomography
...Show More Authors

Abstract Background: This study is aimed to assess the maxillary incisors’ root position, angulation, and buccal alveolar bone thickness in both genders and different classes of malocclusion using cone‑beam computed tomography (CBCT). Materials and Methods: Two hundred and six CBCT images were gathered and analyzed by three‑dimensional On‑Demand software to measure the variables of 803 maxillary central and lateral incisors. Genders and class difference was determined by unpaired t‑test, one‑way ANOVA, and Chi‑square tests. Results: Buccal root position of the maxillary incisors accounted for in the majority of the cases followed by the middle and palatal positions. The thickness of alveolar bone appears to have nearly the sam

... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Medico-legal Update
Evaluation of technical quality and procedural errors of root canal treatment performed by undergraduate and postgraduate dental students: A retrospective radiographic analysis
...Show More Authors

Scopus (3)
Scopus
Publication Date
Fri Apr 18 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of maxillary sinus septal type and height in partially edentulous maxilla using spiral computed tomography
...Show More Authors

Background: The presence of anatomic variations within the maxillary sinus such as septa has been reported to increase the risk of sinus membrane perforation during sinus elevation procedure for implant placement. This study aimed to measure the septal heights and correlate it with different types of septa. Material and methods: Thirty patients (15 males and 15 females) with partially edentulous maxillae and mean age (35) years were enrolled in this study. Sixty sinuses scanned with Spiral multislice Computed Tompgraphy, septal height measured after evaluation of septal type whether it was primary or secondary. Results: The results showed that 72.5 % of the septa detected were primary and this is statistically significant when compared w

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 23 2019
Journal Name
Al-kindy College Medical Journal
Primary Hydatid Cyst of Parotid Gland: A Rare Case Diagnosed by Computed Tomography
...Show More Authors

Hydatid disease is a zoonotic infection caused by Echinococcus species. The cystic form of this infection mostly involves liver and lung. Hydatid disease of the parotid gland even in endemic regions is a very rare entity that may be easily overlooked in daily practice. Herein, I present a case report of a 60-year-old Iraqi female patient who presented with a progressively painless mass in her right parotid. It was diagnosed radiologically as a hydatid cyst and was excised successfully. Histopathologic examination of the resected specimen confirmed the hydatid cyst. This case emphasizes the importance of considering hydatidosis in the differential diagnosis of any parotid mass, especially in endemic countries.

 

&nbsp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 18 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Propolis from Kurdistan region as a new resinous sealer in root canal obturation-part I biocompatibility study
...Show More Authors

Background: Many materials were proposed as root canal obturating materials but the biocompatibility issue remains to be a critical one. Propolis has been used as a therapeutic agent since the time of Hippocrates. It is known that propolis exhibits some pharmacological activities, such as antibacterial, antiviral, antifungal and anti inflammatory activity. Materials and methods: Eighteen albino rats were used in the study and divided randomly into three groups of 6 animals for each group. Each group was scheduled to be sacrificed at different time periods, which were three days, one week and three weeks. Propolis and ZOE sealer implants of 4mm in diameter and 0.5 gm in weight were implanted in the dorsal side of the rats. At the end of the

... Show More
View Publication Preview PDF