Preferred Language
Articles
/
jbcd-291
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were scanned using Computed Tomography (Initial scan). After canal preparation with ProTaper (group A), BioRaCe (group B), and Self Adjusting File (group C) the roots were rescanned (Final scan), the degree of canal transportation and centering ability were assessed at apical (4 mm), middle (6 mm), coronal (9 mm) sections using computed tomography. The collected data were statistically analyzed using ANOVA and Least Significant Difference tests. Results: There were no statistically significant differences among the groups at level 4 mm and level 9 mm (P ? 0.05). However, at level 6 mm there was a highly significant difference between (A) and (B) groups (P ? 0.01) and there was a significant difference between (A) and (C) groups (P ? 0.05). There were no statistically significant differences among different levels of (A) and (C) groups (P ? 0.05), while (B) group showed a highly significant difference between 4 mm and 9 mm levels and between 6 mm and 9 mm levels (P ? 0.01). Regarding canal centering ability, there was no statistically significant difference among the three groups at different levels (P ? 0.05)., while (B) group showed a significant difference between 4 mm and 9 mm levels (P ? 0.05), and a very highly significant difference between 6 mm and 9 mm levels (P ? 0.001). Conclusion: The study demonstrated that canal preparation with the three designs of Ni-Ti instruments produced canal transportation. Self Adjusting File group showed less canal transportation than ProTaper group. There was a comparable value of canal centering ability among different levels in each group except in BioRaCe group.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 07 2018
Journal Name
Oral And Maxillofacial Surgery
Mandibular war injuries caused by bullets and shell fragments: a comparative study
...Show More Authors

View Publication
Scopus (8)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Aug 07 2018
Journal Name
Oral And Maxillofacial Surgery
Mandibular war injuries caused by bullets and shell fragments: a comparative study
...Show More Authors

View Publication
Scopus (8)
Crossref (12)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences 318, 03002 (2021)
A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
...Show More Authors

This paper studies the behavior of axially loaded RC columns which are confined with carbon fiber reinforced polymers’ sheet (CFRP) and steel jackets (SJ). The study is based on twelve axially loaded RC columns tested up to failure. It is divided into three schemes based on its strengthening type; each scheme has four columns. The main parameters in this study were the compressive strength of the concrete and steel reinforcement ratio. Furthermore, the results of the experimental test showed a substantial enhancement in the column's load-carrying capacity. When compared to the original columns, the CFRP sheet had a significant effect on improving the ductility of the column by increasing the axial deformation by about 59.2 to 95.7

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Oral And Maxillofacial Surgery
Characteristics of mandibular injuries caused by bullets and improvised explosive devices: a comparative study
...Show More Authors

The purpose of this study was to investigate the difference in mandibular trauma caused by two mechanisms for the delivery of missile injuries: firearms and improvised explosive devices (IEDs). The data investigated included sex, age, mechanism of injury, and other clinical and radiographic manifestations. Seventy consecutive patients, predominantly male, with a mean age of 28.6 ± 14 years (range 2–60 years) were enrolled: 38 patients (54.3%) sustained mandibular fractures caused by bullet injuries and 32 patients (45.7%) had mandibular fractures caused by IED explosion injuries. The study revealed that the differences in most of the investigated variables were not statistically significant; the only significant differences were the inci

... Show More
View Publication
Scopus (9)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
A study the electrical properties of a Se:2.5%as thin films prepared by thermal cvaporation
...Show More Authors

thin films of se:2.5% as were deposited on a glass substates by thermal coevaporation techniqi=ue under high vacuum at different thikness

View Publication Preview PDF
Crossref
Publication Date
Tue Oct 10 2023
Journal Name
Journal Of Craniofacial Surgery
Cone Beam Computed Tomographic Evaluation of Schneiderian Membrane Thickness
...Show More Authors

This study aimed to determine the measurements and classification of Schneider membrane thickness correlated to age and sex factors using cone beam computed tomography (CBCT). Methods: The study included CBCT images for 100 maxillary sinuses of 50 consecutive patients, and the thickness of the maxillary sinus membrane (Schneiderian membrane) was measured in coronal view from the lowest point in the floor of the maxillary sinus to the highest point. The thickness of the Schneiderian membrane was classified into 4 types. Results: The study result revealed that out of the total cases, 45% of sinus membranes were classified as type 2, while only 10% were classified as type 4. The most frequent type of membrane thickness diagnosed in the age gro

... Show More
View Publication
Scopus (2)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Study the Ability of Pseudomonas Aeruginosa Isolated from Different Clinical Cases to Biofilm Formation and Detection of Algd Gene.
...Show More Authors

98 samples were collected from various clinical sources included (Burns, wounds, urines, sputums, blood) From the city of Baghdad, After performing the biochemical and microscopic examination, 52 isolates were obtained for Pseudomonas aeruginosa, 17 (32.7%) isolates from burn infection, 12 (23%) isolates from Wound infection 11 (21.2%) isolates from urine infection, 7 (13.5%) isolates of sputum and 5 (9.6%) isolates from blood. Bacteria susceptibility to form biofilm has been detectedby microtiter plate method, The results showed that 80% of the bacterial isolates were produced the biofilm with different proportions, alg D gene (alginate production) has been detected by polymerase chain reaction (PCR) Which plays an essential role in the fo

... Show More
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Evaluation of an education program upon women's knowledge toward management of Breast Self – Examination(BSE)
...Show More Authors

To determine the evaluation of education program on women's knowledge regarding managing BSE. The present quasi- experimental study, Non-probability (purposive), sample consisting of (260) women who are employee, and students in both colleges (Nursing college, Medical and Health Techniques College). The sample consist of two groups, study group (130) including those in (Nursing college), and control group (130) in (Medical and Health Techniques College). A questionnaire was constructed which included, Demographic information, Reproductive information, Family history, Previous medical history, and information about women's knowledge toward management of breast self examination (BSE). Instrument validity and reliability was determined. Data w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 04 2020
Journal Name
Fibers
A Comparative Study of the Performance of Slender Reinforced Concrete Columns with Different Cross-Sectional Shapes
...Show More Authors

Most reinforced concrete (RC) structures are constructed with square/rectangular columns. The cross-section size of these types of columns is much larger than the thickness of their partitions. Therefore, parts of these columns are protruded out of the partitions. The emergence of columns edges out of the walls has some disadvantages. This limitation is difficult to be overcome with square or rectangular columns. To solve this problem, new types of RC columns called specially shaped reinforced concrete (SSRC) columns have been used as hidden columns. Besides, the use of SSRC columns provides many structural and architectural advantages as compared with rectangular columns. Therefore, this study was conducted to explain the structura

... Show More
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Oct 12 2017
Journal Name
Iraqi Journal Of Laser
A Comparative Evaluation of Post-Operative Pain and Function after Gingival Depigmentation Using 940 Nm Diode Laser And Conventional Bur Method: 6 Months Study
...Show More Authors

The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in

... Show More
View Publication Preview PDF